A robust sensor-selection method for P300 brain–computer interfaces
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
A brain-computer interface (BCI) is a specific type of human-computer interface that enables direct communication between human and computer through decoding of brain activity. As such, event-related potentials like the P300 can be obtained with an oddball paradigm whose targets are selected by the user. This paper deals with methods to reduce the needed set of EEG sensors in the P300 speller application. A reduced number of sensors yields more comfort for the user, decreases installation time duration, may substantially reduce the financial cost of the BCI setup and may reduce the power consumption for wireless EEG caps. Our new approach to select relevant sensors is based on backward elimination using a cost function based on the signal to signal-plus-noise ratio, after some spatial filtering. We show that this cost function selects sensors' subsets that provide a better accuracy in the speller recognition rate during the test sessions than selected subsets based on classification accuracy. We validate our selection strategy on data from 20 healthy subjects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Updating P300: An integrative theory of P3a and P3b
Polich, J. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2007.04.019 · Cited by 7,919
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228 · cited 2×
“In the experiments, we consider a 6 × 6 matrix, as used in classical P300 spellers [24].”
MethodEvoked-potential correlates of stimulus uncertainty
Sutton, S., Braren, M., Zubin, J., & John, E. R. (1965) · Science · doi:10.1126/science.150.3700.1187 · Cited by 3,061
A review of classification algorithms for EEG-based brain–computer interfaces
Lotte, F., Congedo, M., Lécuyer, A., Lamarche, F., & Arnaldi, B. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r01 · Cited by 2,665
Self-citationAn efficient P300-based brain–computer interface for disabled subjects
Hoffmann, U., Vesin, J.-M., Ebrahimi, T., & Diserens, K. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.03.005 · Cited by 859 · cited 3×
“Neural networks [9–14], support vector machines [15, 16], linear discriminant analysis (classical, stepwise, Bayesian) [17, 18] and hidden Markov models [19, 20] have already been applied to BCI and EEG data classification.”
BackgroundMethodConvolutional Neural Networks for P300 Detection with Application to Brain-Computer Interfaces
Cecotti, H., & Graser, A. (2011) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2010.125 · Cited by 778
Self-citationToward enhanced p300 speller performance
Krusienski, D. J., Sellers, E. W., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.07.017 · Cited by 749 · cited 3×
“Neural networks [9–14], support vector machines [15, 16], linear discriminant analysis (classical, stepwise, Bayesian) [17, 18] and hidden Markov models [19, 20] have already been applied to BCI and EEG data classification.”
BackgroundHow many people are able to control a P300-based brain-computer interface (BCI)?
Guger, C., Daban, S., Sellers, E., Holzner, C., Krausz, G., Carabalona, R., Gramatica, F., & Edlinger, G. (2009) · Neuroscience Letters · doi:10.1016/j.neulet.2009.06.045 · Cited by 652
xDAWN Algorithm to Enhance Evoked Potentials: Application to Brain–Computer Interface
Rivet, B., Souloumiac, A., Attina, V., & Gibert, G. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2012869 · Cited by 537 · cited 1×
“The considered method for creating spatial filters is based on the xDAWN algorithm [36, 37].”
MethodSelf-citationHow many people are able to operate an EEG-based brain-computer interface (BCI)?
Guger, C., Edlinger, G., Harkam, W., Niedermayer, I., & Pfurtscheller, G. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814481 · Cited by 526
Cited by
Cecotti, H., Eckstein, M. P., & Giesbrecht, B. (2014) · IEEE Transactions on Neural Networks and Learning Systems · doi:10.1109/tnnls.2014.2302898 · Cited by 109
Self-citationA covert attention P300-based brain–computer interface: Geospell
Aloise, F., Aricò, P., Schettini, F., Riccio, A., Salinari, S., Mattia, D., Babiloni, F., & Cincotti, F. (2012) · Ergonomics · doi:10.1080/00140139.2012.661084 · Cited by 88
Marathe, A. R., Lawhern, V. J., Wu, D., Slayback, D., & Lance, B. J. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2502323 · Cited by 64
Shan, H., Liu, Y., & Stefanov, T. (2018) · Proceedings of the Twenty-Seventh International Joint Conference on Artificial Intelligence · doi:10.24963/ijcai.2018/222 · Cited by 53
Performance Enhancement of P300 Detection by Multiscale-CNN
Wang, H., Pei, Z., Xu, L., Xu, T., Bezerianos, A., Sun, Y., & Li, J. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3067943 · Cited by 35
Metadata
- Authors
- Cecotti, H., Rivet, B., Congedo, M., Jutten, C., Bertrand, O., Maby, E., & Mattout, J.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2011-01-19
- Volume
- 8
- Issue
- 1
- Pages
- 016001
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2056083531
- Cited by
- 106
- References
- 12
- FWCI
- 6.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A robust sensor-selection method for P300 brain–computer interfaces. https://app.cochat.ai/papers/10.1088/1741-2560/8/1/016001
- The paper
- Cecotti, H., Rivet, B., Congedo, M., Jutten, C., Bertrand, O., Maby, E., & Mattout, J. (2011). A robust sensor-selection method for P300 brain–computer interfaces. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/8/1/016001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.