The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Sensorimotor rhythm-based brain–computer interface training: the impact on motor cortical responsiveness
Open accessAbstract
The main purpose of electroencephalography (EEG)-based brain-computer interface (BCI) technology is to provide an alternative channel to support communication and control when motor pathways are interrupted. Despite the considerable amount of research focused on the improvement of EEG signal detection and translation into output commands, little is known about how learning to operate a BCI device may affect brain plasticity. This study investigated if and how sensorimotor rhythm-based BCI training would induce persistent functional changes in motor cortex, as assessed with transcranial magnetic stimulation (TMS) and high-density EEG. Motor imagery (MI)-based BCI training in naïve participants led to a significant increase in motor cortical excitability, as revealed by post-training TMS mapping of the hand muscle's cortical representation; peak amplitude and volume of the motor evoked potentials recorded from the opponens pollicis muscle were significantly higher only in those subjects who develop a MI strategy based on imagination of hand grasping to successfully control a computer cursor. Furthermore, analysis of the functional brain networks constructed using a connectivity matrix between scalp electrodes revealed a significant decrease in the global efficiency index for the higher-beta frequency range (22-29 Hz), indicating that the brain network changes its topology with practice of hand grasping MI. Our findings build the neurophysiological basis for the use of non-invasive BCI technology for monitoring and guidance of motor imagery-dependent brain plasticity and thus may render BCI a viable tool for post-stroke rehabilitation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Complex brain networks: graph theoretical analysis of structural and functional systems
Bullmore, E., & Sporns, O. (2009) · Nature Reviews Neuroscience · doi:10.1038/nrn2575 · Cited by 11,820
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
A new method for off-line removal of ocular artifact
Gratton, G., Coles, M. G. H., & Donchin, E. (1983) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(83)90135-9 · Cited by 5,055
Rossini, P. M., Barker, A. T., Berardelli, A., Caramia, M. D., Caruso, G., Cracco, R. Q., Dimitrijević, M. R., Hallett, M., Katayama, Y., Lücking, C. H., et al. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90029-9 · Cited by 3,030
Neural simulation of action: a unifying mechanism for motor cognition.
Jeannerod, M. (2001) · NeuroImage · doi:10.1006/nimg.2001.0832 · Cited by 2,563
Rapid plasticity of human cortical movement representation induced by practice
Classen, J., Liepert, J., Wise, S. P., Hallett, M., & Cohen, L. G. (1998) · Journal of Neurophysiology · doi:10.1152/jn.1998.79.2.1117 · Cited by 1,156
Lotze, M., Montoya, P., Erb, M., Hülsmann, E., Flor, H., Klose, U., Birbaumer, N., & Grodd, W. (1999) · Journal of Cognitive Neuroscience · doi:10.1162/089892999563553 · Cited by 993
Neurophysiological predictor of SMR-based BCI performance
Blankertz, B., Sannelli, C., Halder, S., Hammer, E. M., Kübler, A., Müller, K.-R., Curio, G., & Dickhaus, T. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.03.022 · Cited by 674
Self-citationCorticospinal excitability is specifically modulated by motor imagery: a magnetic stimulation study
Fadiga, L., Buccino, G., Craighero, L., Fogassi, L., Gallese, V., & Pavesi, G. (1998) · Neuropsychologia · doi:10.1016/s0028-3932(98)00089-x · Cited by 474
High-resolution EEG techniques for brain-computer interface applications
Cincotti, F., Mattia, D., Aloise, F., Bufalari, S., Astolfi, L., De Vico Fallani, F., Tocci, A., Bianchi, L., Marciani, M. G., Gao, S., et al. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.06.031 · Cited by 115
Self-citation
Cited by
Brain–computer interface boosts motor imagery practice during stroke recovery
Pichiorri, F., Morone, G., Petti, M., Toppi, J., Pisotta, I., Molinari, M., Paolucci, S., Inghilleri, M., Astolfi, L., Cincotti, F., et al. (2015) · Annals of Neurology · doi:10.1002/ana.24390 · Cited by 663
Self-citationBrain–Computer Interfaces Using Sensorimotor Rhythms: Current State and Future Perspectives
Yuan, H., & He, B. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2312397 · Cited by 492
Performance variation in motor imagery brain–computer interface: A brief review
Ahn, M., & Jun, S. C. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.01.033 · Cited by 316
Xu, R., Jiang, N., Lin, C., Mrachacz-Kersting, N., Dremstrup, K., & Farina, D. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2294203 · Cited by 219
BMI control of a third arm for multitasking
Penaloza, C. I., & Nishio, S. (2018) · Science Robotics · doi:10.1126/scirobotics.aat1228 · Cited by 169
Metadata
- Authors
- Pichiorri, F., De Vico Fallani, F., Cincotti, F., Babiloni, F., Molinari, M., Kleih, S. C., Neuper, C., Kübler, A., & Mattia, D.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2011-03-24
- Volume
- 8
- Issue
- 2
- Pages
- 025020
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2094923942
- Cited by
- 162
- References
- 10
- FWCI
- 6.33
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sensorimotor rhythm-based brain–computer interface training: the impact on motor cortical responsiveness. https://app.cochat.ai/papers/10.1088/1741-2560/8/2/025020
- The paper
- Pichiorri, F., De Vico Fallani, F., Cincotti, F., Babiloni, F., Molinari, M., Kleih, S. C., Neuper, C., Kübler, A., & Mattia, D. (2011). Sensorimotor rhythm-based brain–computer interface training: the impact on motor cortical responsiveness. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/8/2/025020
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.