The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Optimized multi-electrode stimulation increases focality and intensity at target
Open accessAbstract
Transcranial direct current stimulation (tDCS) provides a non-invasive tool to elicit neuromodulation by delivering current through electrodes placed on the scalp. The present clinical paradigm uses two relatively large electrodes to inject current through the head resulting in electric fields that are broadly distributed over large regions of the brain. In this paper, we present a method that uses multiple small electrodes (i.e. 1.2 cm diameter) and systematically optimize the applied currents to achieve effective and targeted stimulation while ensuring safety of stimulation. We found a fundamental trade-off between achievable intensity (at the target) and focality, and algorithms to optimize both measures are presented. When compared with large pad-electrodes (approximated here by a set of small electrodes covering 25 cm(2)), the proposed approach achieves electric fields which exhibit simultaneously greater focality (80% improvement) and higher target intensity (98% improvement) at cortical targets using the same total current applied. These improvements illustrate the previously unrecognized and non-trivial dependence of the optimal electrode configuration on the desired electric field orientation and the maximum total current (due to safety). Similarly, by exploiting idiosyncratic details of brain anatomy, the optimization approach significantly improves upon prior un-optimized approaches using small electrodes. The analysis also reveals the optimal use of conventional bipolar montages: maximally intense tangential fields are attained with the two electrodes placed at a considerable distance from the target along the direction of the desired field; when radial fields are desired, the maximum-intensity configuration consists of an electrode placed directly over the target with a distant return electrode. To summarize, if a target location and stimulation orientation can be defined by the clinician, then the proposed technique is superior in terms of both focality and intensity as compared to previous solutions and is thus expected to translate into improved patient safety and increased clinical efficacy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Regression shrinkage and selection via the lasso
Tibshirani, R. (1996) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1996.tb02080.x · Cited by 51,482
Golub, G. (2012) · doi:10.56021/9781421407944 · Cited by 34,505
Delorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371
Nitsche, M. A., & Paulus, W. (2000) · The Journal of Physiology · doi:10.1111/j.1469-7793.2000.t01-1-00633.x · Cited by 5,656
Two decades of array signal processing research: the parametric approach
Krim, H., & Viberg, M. (1996) · IEEE Signal Processing Magazine · doi:10.1109/79.526899 · Cited by 4,719
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/002 · Cited by 4,270
Beamforming: a versatile approach to spatial filtering
Van Veen, B. D., & Buckley, K. M. (1988) · IEEE ASSP Magazine · doi:10.1109/53.665 · Cited by 3,901
Regression Shrinkage and Selection via The Lasso: A Retrospective
Tibshirani, R. (2011) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.1467-9868.2011.00771.x · Cited by 3,589
Introduction to Electrodynamics
Griffiths, D. J. (2017) · Cambridge University Press eBooks · doi:10.1017/9781108333511 · Cited by 3,408
An algorithm for linearly constrained adaptive array processing
Frost, O. L. (1972) · Proceedings of the IEEE · doi:10.1109/proc.1972.8817 · Cited by 2,533
Cited by
Antal, A., Alekseichuk, I., Bikson, M., Brockmöller, J., Brunoni, A. R., Chen, R., Cohen, L. G., Dowthwaite, G., Ellrich, J., Flöel, A., et al. (2017) · Clinical Neurophysiology · doi:10.1016/j.clinph.2017.06.001 · Cited by 1,301
Self-citationHerrmann, C. S., Rach, S., Neuling, T., & Strüber, D. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00279 · Cited by 813
Determinants of the electric field during transcranial direct current stimulation
Opitz, A., Paulus, W., Will, S., Antunes, A., & Thielscher, A. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.01.033 · Cited by 690
Immediate neurophysiological effects of transcranial electrical stimulation
Liu, A., Vöröslakos, M., Kronberg, G., Henin, S., Krause, M. R., Huang, Y., Opitz, A., Mehta, A., Pack, C. C., Krekelberg, B., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-07233-7 · Cited by 589
Self-citationHuang, Y., Liu, A. A., Lafon, B., Friedman, D., Dayan, M., Wang, X., Bikson, M., Doyle, W. K., Devinsky, O., & Parra, L. C. (2017) · eLife · doi:10.7554/elife.18834 · Cited by 556
Self-citation
Metadata
- Authors
- Dmochowski, J. P., Datta, A., Bikson, M., Su, Y., & Parra, L. C.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2011-06-10
- Volume
- 8
- Issue
- 4
- Pages
- 046011
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2126906058
- Cited by
- 590
- References
- 42
- FWCI
- 13.28
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimized multi-electrode stimulation increases focality and intensity at target. https://app.cochat.ai/papers/10.1088/1741-2560/8/4/046011
- The paper
- Dmochowski, J. P., Datta, A., Bikson, M., Su, Y., & Parra, L. C. (2011). Optimized multi-electrode stimulation increases focality and intensity at target. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/8/4/046011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.