Optimized multi-electrode stimulation increases focality and intensity at target
Open accessThe DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
Transcranial direct current stimulation (tDCS) provides a non-invasive tool to elicit neuromodulation by delivering current through electrodes placed on the scalp. The present clinical paradigm uses two relatively large electrodes to inject current through the head resulting in electric fields that are broadly distributed over large regions of the brain. In this paper, we present a method that uses multiple small electrodes (i.e. 1.2 cm diameter) and systematically optimize the applied currents to achieve effective and targeted stimulation while ensuring safety of stimulation. We found a fundamental trade-off between achievable intensity (at the target) and focality, and algorithms to optimize both measures are presented. When compared with large pad-electrodes (approximated here by a set of small electrodes covering 25 cm(2)), the proposed approach achieves electric fields which exhibit simultaneously greater focality (80% improvement) and higher target intensity (98% improvement) at cortical targets using the same total current applied. These improvements illustrate the previously unrecognized and non-trivial dependence of the optimal electrode configuration on the desired electric field orientation and the maximum total current (due to safety). Similarly, by exploiting idiosyncratic details of brain anatomy, the optimization approach significantly improves upon prior un-optimized approaches using small electrodes. The analysis also reveals the optimal use of conventional bipolar montages: maximally intense tangential fields are attained with the two electrodes placed at a considerable distance from the target along the direction of the desired field; when radial fields are desired, the maximum-intensity configuration consists of an electrode placed directly over the target with a distant return electrode. To summarize, if a target location and stimulation orientation can be defined by the clinician, then the proposed technique is superior in terms of both focality and intensity as compared to previous solutions and is thus expected to translate into improved patient safety and increased clinical efficacy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Regression shrinkage and selection via the lasso
Tibshirani, R. (1996) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1996.tb02080.x · Cited by 51,482
Golub, G. (2012) · doi:10.56021/9781421407944 · Cited by 34,505
Delorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371
Nitsche, M. A., & Paulus, W. (2000) · The Journal of Physiology · doi:10.1111/j.1469-7793.2000.t01-1-00633.x · Cited by 5,656
Two decades of array signal processing research: the parametric approach
Krim, H., & Viberg, M. (1996) · IEEE Signal Processing Magazine · doi:10.1109/79.526899 · Cited by 4,719
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/002 · Cited by 4,270
Beamforming: a versatile approach to spatial filtering
Van Veen, B. D., & Buckley, K. M. (1988) · IEEE ASSP Magazine · doi:10.1109/53.665 · Cited by 3,901
Regression Shrinkage and Selection via The Lasso: A Retrospective
Tibshirani, R. (2011) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.1467-9868.2011.00771.x · Cited by 3,589
Introduction to Electrodynamics
Griffiths, D. J. (2017) · Cambridge University Press eBooks · doi:10.1017/9781108333511 · Cited by 3,408
An algorithm for linearly constrained adaptive array processing
Frost, O. L. (1972) · Proceedings of the IEEE · doi:10.1109/proc.1972.8817 · Cited by 2,533
Cited by
Safety of Transcranial Direct Current Stimulation: Evidence Based Update 2016
Bikson, M., Grossman, P., Thomas, C., Zannou, A. L., Jiang, J., Adnan, T., Mourdoukoutas, A. P., Kronberg, G., Truong, D., Boggio, P., et al. (2016) · Brain Stimulation · doi:10.1016/j.brs.2016.06.004 · Cited by 1,396
Self-citationAntal, A., Alekseichuk, I., Bikson, M., Brockmöller, J., Brunoni, A. R., Chen, R., Cohen, L. G., Dowthwaite, G., Ellrich, J., Flöel, A., et al. (2017) · Clinical Neurophysiology · doi:10.1016/j.clinph.2017.06.001 · Cited by 1,301
Self-citationHerrmann, C. S., Rach, S., Neuling, T., & Strüber, D. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00279 · Cited by 813
Determinants of the electric field during transcranial direct current stimulation
Opitz, A., Paulus, W., Will, S., Antunes, A., & Thielscher, A. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.01.033 · Cited by 690
Immediate neurophysiological effects of transcranial electrical stimulation
Liu, A., Vöröslakos, M., Kronberg, G., Henin, S., Krause, M. R., Huang, Y., Opitz, A., Mehta, A., Pack, C. C., Krekelberg, B., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-07233-7 · Cited by 589
Self-citationHuang, Y., Liu, A. A., Lafon, B., Friedman, D., Dayan, M., Wang, X., Bikson, M., Doyle, W. K., Devinsky, O., & Parra, L. C. (2017) · eLife · doi:10.7554/elife.18834 · Cited by 556
Self-citationEdwards, D., Cortes, M., Datta, A., Minhas, P., Wassermann, E. M., & Bikson, M. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.01.042 · Cited by 468
Self-citationOrigins of specificity during tDCS: anatomical, activity-selective, and input-bias mechanisms
Bikson, M., name, A., & Rahman, A. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00688 · Cited by 410
Self-citationHuang, Y., Datta, A., Bikson, M., & Parra, L. C. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab208d · Cited by 362
Self-citationTranscranial Alternating Current and Random Noise Stimulation: Possible Mechanisms
Antal, A., & Herrmann, C. S. (2016) · Neural Plasticity · doi:10.1155/2016/3616807 · Cited by 357
Ruffini, G., Fox, M. D., Ripolles, O., Miranda, P. C., & Pascual-Leone, A. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.12.002 · Cited by 351
Induction of self awareness in dreams through frontal low current stimulation of gamma activity
Voss, U., Holzmann, R., Hobson, A., Paulus, W., Koppehele-Gossel, J., Klimke, A., & Nitsche, M. A. (2014) · Nature Neuroscience · doi:10.1038/nn.3719 · Cited by 340
The electric field in the cortex during transcranial current stimulation
Miranda, P. C., Mekonnen, A., Salvador, R., & Ruffini, G. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.12.034 · Cited by 334
Selective Modulation of Interhemispheric Functional Connectivity by HD-tACS Shapes Perception
Helfrich, R. F., Knepper, H., Nolte, G., Strüber, D., Rach, S., Herrmann, C. S., Schneider, T. R., & Engel, A. K. (2014) · PLoS Biology · doi:10.1371/journal.pbio.1002031 · Cited by 320
Opitz, A., Falchier, A., Yan, C.-G., Yeagle, E. M., Linn, G. S., Megevand, P., Thielscher, A., Deborah A., R., Milham, M. P., Mehta, A. D., et al. (2016) · Scientific Reports · doi:10.1038/srep31236 · Cited by 317
tDCS‐Induced Analgesia and Electrical Fields in Pain‐Related Neural Networks in Chronic Migraine
DaSilva, A. F., Mendonca, M. E., Zaghi, S., Lopes, M., DosSantos, M. F., Spierings, E. L., Bajwa, Z., Datta, A., Bikson, M., & Fregni, F. (2012) · Headache: The Journal of Head and Face Pain · doi:10.1111/j.1526-4610.2012.02141.x · Cited by 305
Self-citationChase, H. W., Boudewyn, M. A., Carter, C. S., & Phillips, M. L. (2020) · Molecular Psychiatry · doi:10.1038/s41380-019-0499-9 · Cited by 286
“such that high-definition (HD) montages are now available in addition to traditional anode-cathode pair montages [41].”
BackgroundComputational Models of Transcranial Direct Current Stimulation
Bikson, M., Rahman, A., & Datta, A. (2012) · Clinical EEG and Neuroscience · doi:10.1177/1550059412445138 · Cited by 283
Self-citationNon-invasive Human Brain Stimulation in Cognitive Neuroscience: A Primer
Parkin, B. L., Ekhtiari, H., & Walsh, V. F. (2015) · Neuron · doi:10.1016/j.neuron.2015.07.032 · Cited by 273
On the importance of electrode parameters for shaping electric field patterns generated by tDCS
Saturnino, G. B., Antunes, A., & Thielscher, A. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.06.067 · Cited by 263
Villamar, M. F., Volz, M. S., Bikson, M., Datta, A., DaSilva, A. F., & Fregni, F. (2013) · Journal of Visualized Experiments · doi:10.3791/50309 · Cited by 261
Self-citationHuang, Y., Parra, L. C., & Haufe, S. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.12.019 · Cited by 259
Self-citationFaria, P., Hallett, M., & Miranda, P. C. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/6/066017 · Cited by 243
Reed, T., & Cohen Kadosh, R. (2018) · Journal of Inherited Metabolic Disease · doi:10.1007/s10545-018-0181-4 · Cited by 235
Guleyupoglu, B., Schestatsky, P., Edwards, D., Fregni, F., & Bikson, M. (2013) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2013.07.016 · Cited by 224
“HD-tDCS electrodes were designed for increased charge-passage capacity through smaller a contact area (Minhas et al., 2010), arranged in arrays that can be optimized per indication (Dmochowski et al., 2011).”
InfluentialSelf-citationKessler, S. K., Minhas, P., Woods, A. J., Rosen, A., Gorman, C., & Bikson, M. (2013) · PLoS ONE · doi:10.1371/journal.pone.0076112 · Cited by 208
“These findings are consistent with studies exploring the relationships between electrode area, inter-electrode distance, and the distribution of current density in tDCS [12,30].”
Self-citationIncomplete evidence that increasing current intensity of tDCS boosts outcomes
Esmaeilpour, Z., Marangolo, P., Hampstead, B. M., Bestmann, S., Galletta, E., Knotkova, H., & Bikson, M. (2018) · Brain Stimulation · doi:10.1016/j.brs.2017.12.002 · Cited by 200
“identified by fMRI), approaches to individualize HD-tDCS therapy were developed [28,47] but, even if these trials were conducted, the underlying assumption on dose response remains to be validated.”
Self-citationLafon, B., Henin, S., Huang, Y., Friedman, D., Melloni, L., Thesen, T., Doyle, W., Buzsáki, G., Devinsky, O., Parra, L. C., et al. (2017) · Nature Communications · doi:10.1038/s41467-017-01045-x · Cited by 198
Self-citationTranscranial Current Brain Stimulation (tCS): Models and Technologies
Ruffini, G., Wendling, F., Merlet, I., Molaee-Ardekani, B., Mekonnen, A., Salvador, R., Soria-Frisch, A., Grau, C., Dunne, S., & Miranda, P. C. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2200046 · Cited by 197
“More sophisticated methods that can optimize both the magnitude of the electric field and its direction in the target region have been reported [69].”
MethodAlam, M., Truong, D. Q., Khadka, N., & Bikson, M. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/12/4506 · Cited by 197
Self-citationVillamar, M. F., Wivatvongvana, P., Patumanond, J., Bikson, M., Truong, D. Q., Datta, A., & Fregni, F. (2013) · The Journal of Pain · doi:10.1016/j.jpain.2012.12.007 · Cited by 194
Self-citationTruong, D. Q., Magerowski, G., Blackburn, G. L., Bikson, M., & Alonso-Alonso, M. (2013) · NeuroImage: Clinical · doi:10.1016/j.nicl.2013.05.011 · Cited by 183
Self-citationNoury, N., Hipp, J. F., & Siegel, M. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.03.065 · Cited by 180
“Transcranial electric stimulation (tES) is a non-invasive brain stimulation technique, which provides the possibility to control stimulation strength, frequency and, to some extent, stimulation site (Dmochowski et al., 2011; Kanai et al., 2008; Schutter and Hortensius, 2010; Schwiedrzik, 2009).”
BackgroundInvestigation of tDCS volume conduction effects in a highly realistic head model
Wagner, S., Rampersad, S. M., Aydin, Ü., Vorwerk, J., Oostendorp, T. F., Neuling, T., Herrmann, C. S., Stegeman, D. F., & Wolters, C. H. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/1/016002 · Cited by 177
Prospects for transcranial temporal interference stimulation in humans: A computational study
Rampersad, S., Roig-Solvas, B., Yarossi, M., Kulkarni, P. P., Santarnecchi, E., Dorval, A. D., & Brooks, D. H. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.116124 · Cited by 166
Dose-controlled tDCS reduces electric field intensity variability at a cortical target site
Evans, C., Bachmann, C., Lee, J. S. A., Gregoriou, E., Ward, N., & Bestmann, S. (2020) · Brain Stimulation · doi:10.1016/j.brs.2019.10.004 · Cited by 164
Using transcranial direct-current stimulation (tDCS) to understand cognitive processing
Reinhart, R. M. G., Cosman, J. D., Fukuda, K., & Woodman, G. F. (2017) · Attention, Perception, & Psychophysics · doi:10.3758/s13414-016-1224-2 · Cited by 163
“A considerable effort is being made with human participants to determine whether tDCS effects are more potent with multi-session tDCS (Dumel et al., 2016; Galvez et al., 2013).”
BackgroundMagnetoencephalography in Cognitive Neuroscience: A Primer
Gross, J. (2019) · Neuron · doi:10.1016/j.neuron.2019.07.001 · Cited by 160
“Another important consideration for MEG-TES studies is the optimization of the stimulation parameters, including electrode location (Dmochowski et al., 2011; Opitz et al., 2018;Wagner et al., 2016).”
Changing Brain Networks Through Non-invasive Neuromodulation
To, W. T., De Ridder, D., Hart Jr., J., & Vanneste, S. (2018) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2018.00128 · Cited by 135
“…has improved the spatial accuracy of conventional tDCS by using arrays of smaller ‘‘highdefinition’’ electrodes instead of two large pad electrodes (Datta et al., 2009; Dmochowski et al., 2011; Guleyupoglu et al., 2013; Villamar et al., 2013a; Heimrath et al., 2015; Shekhawat et al., 2016).”
BackgroundPredicting the electric field distribution in the brain for the treatment of glioblastoma
Miranda, P. C., Mekonnen, A., Salvador, R., & Basser, P. J. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/15/4137 · Cited by 131
Bhattacharjee, S., Kashyap, R., Goodwill, A. M., O'Brien, B. A., Rapp, B., Oishi, K., Desmond, J. E., & Chen, S. H. A. (2022) · Brain Stimulation · doi:10.1016/j.brs.2021.11.018 · Cited by 80
“However, the current direction might be relevant to the cortex's anatomy when specific gyri or sulci are stimulated by a more focal, high-definition electrode configuration [97].”
Senço, N. M., Huang, Y., D’Urso, G., Parra, L. C., Bikson, M., Mantovani, A., Shavitt, R. G., Hoexter, M. Q., Miguel, E. C., & Brunoni, A. R. (2015) · Expert Review of Medical Devices · doi:10.1586/17434440.2015.1037832 · Cited by 67
Self-citationNon-invasive brain stimulation for fatigue in post-acute sequelae of SARS-CoV-2 (PASC)
Santana, K., França, E., Sato, J., Silva, A., Queiroz, M., de Farias, J., Rodrigues, D., Souza, I., Ribeiro, V., Caparelli-Dáquer, E., et al. (2023) · Brain Stimulation · doi:10.1016/j.brs.2023.01.1672 · Cited by 52
Self-citationPripfl, J., & Lamm, C. (2015) · Neuroscience Research · doi:10.1016/j.neures.2014.09.007 · Cited by 45
Rasmussen, I. D., Boayue, N. M., Mittner, M., Bystad, M., Grønli, O. K., Vangberg, T. R., Csifcsák, G., & Aslaksen, P. M. (2021) · Journal of Alzheimer's Disease · doi:10.3233/jad-210378 · Cited by 42
Rezaee, Z., Kaura, S., Solanki, D., Dash, A., Srivastava, M. V. P., Lahiri, U., & Dutta, A. (2020) · Brain Sciences · doi:10.3390/brainsci10020094 · Cited by 31
“The ‘beamforming’ problem in array signal processing [46,50] based”
BackgroundAndrade, S. M., Cecília de Araújo Silvestre, M., Tenório de França, E. É., Bezerra Sales Queiroz, M. H., de Jesus Santana, K., Lima Holmes Madruga, M. L., Torres Teixeira Mendes, C. K., Araújo de Oliveira, E., Bezerra, J. F., Barreto, R. G., et al. (2022) · Brain Stimulation · doi:10.1016/j.brs.2022.05.006 · Cited by 30
Self-citationGlobal activity shaping strategies for a retinal implant
Spencer, M. J., Kameneva, T., Grayden, D. B., Meffin, H., & Burkitt, A. N. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaf071 · Cited by 28
Human-in-the-loop optimization of visual prosthetic stimulation
Fauvel, T., & Chalk, M. (2021) · doi:10.1101/2021.11.24.469867 · Cited by 15
Human-in-the-loop optimization of visual prosthetic stimulation
Fauvel, T., & Chalk, M. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac7615 · Cited by 15
“Similar strategies were applied for transcranial direct current stimulation, so as to achieve intense and focal stimulation (Dmochowski et al., 2011).”
Metadata
- Authors
- Dmochowski, J. P., Datta, A., Bikson, M., Su, Y., & Parra, L. C.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2011-06-10
- Volume
- 8
- Issue
- 4
- Pages
- 046011
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2126906058
- Cited by
- 590
- References
- 42
- FWCI
- 13.28
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.