Detection of movement intention from single-trial movement-related cortical potentials
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Detection of movement intention from neural signals combined with assistive technologies may be used for effective neurofeedback in rehabilitation. In order to promote plasticity, a causal relation between intended actions (detected for example from the EEG) and the corresponding feedback should be established. This requires reliable detection of motor intentions. In this study, we propose a method to detect movements from EEG with limited latency. In a self-paced asynchronous BCI paradigm, the initial negative phase of the movement-related cortical potentials (MRCPs), extracted from multi-channel scalp EEG was used to detect motor execution/imagination in healthy subjects and stroke patients. For MRCP detection, it was demonstrated that a new optimized spatial filtering technique led to better accuracy than a large Laplacian spatial filter and common spatial pattern. With the optimized spatial filter, the true positive rate (TPR) for detection of movement execution in healthy subjects (n = 15) was 82.5 ± 7.8%, with latency of -66.6 ± 121 ms. Although TPR decreased with motor imagination in healthy subject (n = 10, 64.5 ± 5.33%) and with attempted movements in stroke patients (n = 5, 55.01 ± 12.01%), the results are promising for the application of this approach to provide patient-driven real-time neurofeedback.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LIBET, B., GLEASON, C. A., WRIGHT, E. W., & PEARL, D. K. (1983) · Brain · doi:10.1093/brain/106.3.623 · Cited by 2,498
Optimal spatial filtering of single trial EEG during imagined hand movement
Ramoser, H., Muller-Gerking, J., & Pfurtscheller, G. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.895946 · Cited by 2,457 · cited 1×
“The CSP method was first proposed for classification of multi-channel EEG during imagined hand movements [16].”
MethodKalman Filtering and Neural Networks
(2001) · Wiley eBooks · doi:10.1002/0471221546 · Cited by 2,386
Plasticity during stroke recovery: from synapse to behaviour
Murphy, T. H., & Corbett, D. (2009) · Nature Reviews Neuroscience · doi:10.1038/nrn2735 · Cited by 1,938
Spatial filter selection for EEG-based communication
McFarland, D. J., McCane, L. M., David, S. V., & Wolpaw, J. R. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(97)00022-2 · Cited by 936
Voluntary finger movement in man: Cerebral potentials and theory
Deecke, L., Gr�zinger, B., & Kornhuber, H. H. (1976) · Biological Cybernetics · doi:10.1007/bf00336013 · Cited by 757 · cited 1×
“The MRCP consists of a BP, followed by a motor potential (MP) [2] and a movementmonitoring potential (MMP) [3].”
BackgroundThink to Move: a Neuromagnetic Brain-Computer Interface (BCI) System for Chronic Stroke
Buch, E., Weber, C., Cohen, L. G., Braun, C., Dimyan, M. A., Ard, T., Mellinger, J., Caria, A., Soekadar, S., Fourkas, A., et al. (2008) · Stroke · doi:10.1161/strokeaha.107.505313 · Cited by 600
Olejniczak, P. (2006) · Journal of Clinical Neurophysiology · doi:10.1097/01.wnp.0000220079.61973.6c · Cited by 295
A brain-controlled switch for asynchronous control applications
Mason, S. G., & Birch, G. E. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.871402 · Cited by 293
Daly, J. J., Cheng, R., Rogers, J., Litinas, K., Hrovat, K., & Dohring, M. (2009) · Journal of Neurologic Physical Therapy · doi:10.1097/npt.0b013e3181c1fc0b · Cited by 274
Using brain–computer interfaces to induce neural plasticity and restore function
Grosse-Wentrup, M., Mattia, D., & Oweiss, K. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025004 · Cited by 235
Brunner, C., Naeem, M., Leeb, R., Graimann, B., & Pfurtscheller, G. (2007) · Pattern Recognition Letters · doi:10.1016/j.patrec.2007.01.002 · Cited by 187
Slow Potential Changes in the Human Brain
McCallum, W. C., & Curry, S. H. (1993) · Springer eBooks · doi:10.1007/978-1-4899-1597-9 · Cited by 138
Fast set-up asynchronous brain-switch based on detection of foot motor imagery in 1-channel EEG
Müller-Putz, G., Kaiser, V., Solis‐Escalante, T., & Pfurtscheller, G. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-009-0572-7 · Cited by 136
Cerebral potentials preceding unilateral and simultaneous bilateral finger movements
Kristeva, R., Keller, E., Deecke, L., & Kornhuber, H. H. (1979) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(79)90223-2 · Cited by 129
(2003) · Springer eBooks · doi:10.1007/978-1-4615-0189-3 · Cited by 102
Movement-related parameters modulate cortical activity during imaginary isometric plantar-flexions
do Nascimento, O. F., Dremstrup, K., & Voigt, M. (2005) · Experimental Brain Research · doi:10.1007/s00221-005-0247-z · Cited by 83
Self-citationSpatially Regularized Common Spatial Patterns for EEG Classification
Lotte, F., & Guan, C. (2010) · Proceedings - International Conference on Pattern Recognition/Proceedings/International Conference on Pattern Recognition · doi:10.1109/icpr.2010.904 · Cited by 70
Yom‐Tov, E., & Inbar, G. F. (2003) · Medical & Biological Engineering & Computing · doi:10.1007/bf02343543 · Cited by 54
Boye, A. T., Kristiansen, U. Q., Billinger, M., Nascimento, O. F. D., & Farina, D. (2008) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2008.05.001 · Cited by 45
Self-citationUnsupervised movement onset detection from EEG recorded during self-paced real hand movement
Hasan, B. A. S., & Gan, J. Q. (2009) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-009-0550-0 · Cited by 26
Garipelli, G., Chavarriaga, R., & Millán, J. D. R. (2011) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2011.5910573 · Cited by 23
A Maxmin Approach to Optimize Spatial Filters for EEG Single-Trial Classification
Kawanabe, M., Vidaurre, C., Blankertz, B., & Müller, K. (2009) · Lecture notes in computer science · doi:10.1007/978-3-642-02478-8_84 · Cited by 9
Cited by
Mrachacz-Kersting, N., Jiang, N., Stevenson, A. J. T., Niazi, I. K., Kostic, V., Pavlovic, A., Radovanovic, S., Djuric-Jovicic, M., Agosta, F., Dremstrup, K., et al. (2016) · Journal of Neurophysiology · doi:10.1152/jn.00918.2015 · Cited by 275
Self-citationEEG-Based Brain-Computer Interfaces: A Thorough Literature Survey
Hwang, H.-J., Kim, S., Choi, S., & Im, C.-H. (2013) · International Journal of Human-Computer Interaction · doi:10.1080/10447318.2013.780869 · Cited by 257
“In the figure legend, “PSD” and “ERP” stand for “power spectral density” and “event-related potential,” respectively.”
InfluentialUpper limb movements can be decoded from the time-domain of low-frequency EEG
Ofner, P., Schwarz, A., Pereira, J., & Müller-Putz, G. R. (2017) · PLOS ONE · doi:10.1371/journal.pone.0182578 · Cited by 253
Xu, R., Jiang, N., Lin, C., Mrachacz-Kersting, N., Dremstrup, K., & Farina, D. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2294203 · Cited by 219
Self-citationEpileptic Seizures Prediction Using Machine Learning Methods
Usman, S. M., Usman, M., & Fong, S. (2017) · Computational and Mathematical Methods in Medicine · doi:10.1155/2017/9074759 · Cited by 216
“Large Laplacian filter also gives increased signal-to-noise ratio and can be used for surrogate channel [25].”
Background
Metadata
- Authors
- Niazi, I. K., Jiang, N., Tiberghien, O., Nielsen, J. F., Dremstrup, K., & Farina, D.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2011-10-01
- Volume
- 8
- Issue
- 6
- Pages
- 066009
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2076151856
- Cited by
- 259
- References
- 23
- FWCI
- 6.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.