An online brain–computer interface based on shifting attention to concurrent streams of auditory stimuli
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
We report on the development and online testing of an electroencephalogram-based brain-computer interface (BCI) that aims to be usable by completely paralysed users-for whom visual or motor-system-based BCIs may not be suitable, and among whom reports of successful BCI use have so far been very rare. The current approach exploits covert shifts of attention to auditory stimuli in a dichotic-listening stimulus design. To compare the efficacy of event-related potentials (ERPs) and steady-state auditory evoked potentials (SSAEPs), the stimuli were designed such that they elicited both ERPs and SSAEPs simultaneously. Trial-by-trial feedback was provided online, based on subjects' modulation of N1 and P3 ERP components measured during single 5 s stimulation intervals. All 13 healthy subjects were able to use the BCI, with performance in a binary left/right choice task ranging from 75% to 96% correct across subjects (mean 85%). BCI classification was based on the contrast between stimuli in the attended stream and stimuli in the unattended stream, making use of every stimulus, rather than contrasting frequent standard and rare 'oddball' stimuli. SSAEPs were assessed offline: for all subjects, spectral components at the two exactly known modulation frequencies allowed discrimination of pre-stimulus from stimulus intervals, and of left-only stimuli from right-only stimuli when one side of the dichotic stimulus pair was muted. However, attention modulation of SSAEPs was not sufficient for single-trial BCI communication, even when the subject's attention was clearly focused well enough to allow classification of the same trials via ERPs. ERPs clearly provided a superior basis for BCI. The ERP results are a promising step towards the development of a simple-to-use, reliable yes/no communication system for users in the most severely paralysed states, as well as potential attention-monitoring and -training applications outside the context of assistive technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228
Electrical Signs of Selective Attention in the Human Brain
Hillyard, S. A., Hink, R. F., Schwent, V. L., & Picton, T. W. (1973) · Science · doi:10.1126/science.182.4108.177 · Cited by 1,934
A spelling device for the paralysed
Birbaumer, N., Ghanayim, N., Hinterberger, T., Iversen, I., Kotchoubey, B., Kübler, A., Perelmouter, J., Taub, E., & Flor, H. (1999) · Nature · doi:10.1038/18581 · Cited by 1,577 · cited 1×
“It has been shown [1] that some people in a ‘locked-in’ state (LIS), in which most cognitive functions are intact despite almost-complete paralysis, can learn to communicate via an interface that interprets electrical signals from the brain, measured externally by electroencephalogram (EEG).”
Background
Cited by
Rashid, M., Sulaiman, N., P. P. Abdul Majeed, A., Musa, R. M., Ab. Nasir, A. F., Bari, B. S., & Khatun, S. (2020) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2020.00025 · Cited by 506
Simon, N., Käthner, I., Ruf, C. A., Pasqualotto, E., Kübler, A., & Halder, S. (2015) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2014.01039 · Cited by 478
Kwak, N.-S., Müller, K.-R., & Lee, S.-W. (2017) · PLOS ONE · doi:10.1371/journal.pone.0172578 · Cited by 272
Towards a truly mobile auditory brain–computer interface: Exploring the P300 to take away
De Vos, M., Gandras, K., & Debener, S. (2014) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2013.08.010 · Cited by 203
“It is important to realize that the exact extend by which the individuals focused their attention on the target tone while ignoring the distractor is not known (Hill and Schölkopf, 2012).”
BackgroundMethodInfluentialZich, C., Debener, S., Kranczioch, C., Bleichner, M. G., Gutberlet, I., & De Vos, M. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.04.020 · Cited by 180
“5) plus two standard errors 0:5þ 2 ffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffi 0:5 0:5 ð Þ=80 p 1⁄4 0:612 (Hill and Schölkopf, 2012).”
BackgroundEffects of training and motivation on auditory P300 brain-computer interface performance
Baykara, E., Ruf, C. A., Fioravanti, C., Käthner, I., Simon, N., Kleih, S. C., Kübler, A., & Halder, S. (2016) · Clinical Neurophysiology · doi:10.1016/j.clinph.2015.04.054 · Cited by 91
“(2009) Auditory 36 59.4 1.86 Online Healthy Kübler et al. (2009) Auditory 25 12.1 0.05 Online ALS patients Halder et al. (2010) Auditory 2 78.5 2.46 Offline Healthy Höhne et al. (2011) Auditory 9 89.4 4.61 Online Healthy Schreuder et al.”
InfluentialA multi-signature brain–computer interface: use of transient and steady-state responses
Severens, M., Farquhar, J., Duysens, J., & Desain, P. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/2/026005 · Cited by 36
Reichert, C., Tellez Ceja, I. F., Sweeney-Reed, C. M., Heinze, H.-J., Hinrichs, H., & Dürschmid, S. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.591777 · Cited by 23
“Another auditory approach achieved 4.98 bit/min neglecting inter-trial gaps and 85% and 77% accuracy, respectively, (Hill and Schölkopf, 2012; Hill et al., 2014).”
BackgroundInfluential
Metadata
- Authors
- Hill, N. J., & Schölkopf, B.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2012-02-15
- Volume
- 9
- Issue
- 2
- Pages
- 026011
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2171296600
- Cited by
- 105
- References
- 3
- FWCI
- 6.76
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.