Stationary common spatial patterns for brain–computer interfacing
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
Classifying motion intentions in brain-computer interfacing (BCI) is a demanding task as the recorded EEG signal is not only noisy and has limited spatial resolution but it is also intrinsically non-stationary. The non-stationarities in the signal may come from many different sources, for instance, electrode artefacts, muscular activity or changes of task involvement, and often deteriorate classification performance. This is mainly because features extracted by standard methods like common spatial patterns (CSP) are not invariant to variations of the signal properties, thus should also change over time. Although many extensions of CSP were proposed to, for example, reduce the sensitivity to noise or incorporate information from other subjects, none of them tackles the non-stationarity problem directly. In this paper, we propose a method which regularizes CSP towards stationary subspaces (sCSP) and show that this increases classification accuracy, especially for subjects who are hardly able to control a BCI. We compare our method with the state-of-the-art approaches on different datasets, show competitive results and analyse the reasons for the improvement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wu, Y. (1999) · Technometrics · doi:10.1080/00401706.1999.10485951 · Cited by 27,221 · cited 2×
“Stationarity is a necessary assumption of many machine learning algorithms for optimal classification [8].”
BackgroundBrain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927 · cited 1×
“[1–6]) aim to decode the intent of a subject measured from brain signals, e.”
Background(2005) · Cited by 5,977
Optimal spatial filtering of single trial EEG during imagined hand movement
Ramoser, H., Muller-Gerking, J., & Pfurtscheller, G. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.895946 · Cited by 2,457
Optimizing Spatial filters for Robust EEG Single-Trial Analysis
Blankertz, B., Tomioka, R., Lemm, S., Kawanabe, M., & Muller, K.-R. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2008.4408441 · Cited by 2,080 · cited 6×
“BCI data, we do not use fixed preprocessing, but select the best binary task combination and estimate the most discriminative frequency band and time segment (typically 750–3500 ms relative to the presentation of the visual cue) for each subject using calibration data (as done in [9]).”
BackgroundMethodInfluentialSelf-citationA spelling device for the paralysed
Birbaumer, N., Ghanayim, N., Hinterberger, T., Iversen, I., Kotchoubey, B., Kübler, A., Perelmouter, J., Taub, E., & Flor, H. (1999) · Nature · doi:10.1038/18581 · Cited by 1,577 · cited 1×
“[1, 2, 3, 4, 5, 6]) aim to decode the intent of a subject measured from brain signals, e.”
BackgroundReview of the BCI Competition IV
Tangermann, M., Müller, K.-R., Aertsen, A., Birbaumer, N., Braun, C., Brunner, C., Leeb, R., Mehring, C., Miller, K. J., Müller-Putz, G. R., et al. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00055 · Cited by 1,288 · cited 1×
“Data set IIa, BCI Competition IV This data set [38] from BCI Competition IV [39] consists of EEG recordings from 22 Ag/AgCl electrodes and nine healthy subjects performing left hand, right hand, foot and tongue MI without feedback.”
MethodSelf-citationCovariate Shift Adaptation by Importance Weighted Cross Validation
Sugiyama, M., Krauledat, M., & Müller, K. (2007) · Publikationsdatenbank der Fraunhofer-Gesellschaft (Fraunhofer-Gesellschaft) · doi:10.5555/1314498.1390324 · Cited by 1,233
Self-citationSingle-trial analysis and classification of ERP components — A tutorial
Blankertz, B., Lemm, S., Treder, M., Haufe, S., & Müller, K.-R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.06.048 · Cited by 1,138 · cited 1×
“a vector containing the source activities to the signals acquired at the different sensors (cf Blankertz et al [41]), with the best classification performance for CSP, TRCSP, iCSP, SSA+CSP and sCSP.”
BackgroundSelf-citationRegularizing Common Spatial Patterns to Improve BCI Designs: Unified Theory and New Algorithms
Lotte, F., & Guan, C. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2082539 · Cited by 1,045 · cited 9×
“Tikhonov Regularized CSP (TRCSP) penalizes solutions with large weights (see Lotte and Guan [12]).”
BackgroundMethodResultInfluential
Cited by
Learning Temporal Information for Brain-Computer Interface Using Convolutional Neural Networks
Sakhavi, S., Guan, C., & Yan, S. (2018) · IEEE Transactions on Neural Networks and Learning Systems · doi:10.1109/tnnls.2018.2789927 · Cited by 656
Altaheri, H., Muhammad, G., Alsulaiman, M., Amin, S. U., Altuwaijri, G. A., Abdul, W., Bencherif, M. A., & Faisal, M. (2023) · Neural Computing and Applications · doi:10.1007/s00521-021-06352-5 · Cited by 590
Jayaram, V., Alamgir, M., Altun, Y., Scholkopf, B., & Grosse-Wentrup, M. (2016) · IEEE Computational Intelligence Magazine · doi:10.1109/mci.2015.2501545 · Cited by 468
“[23], in which an invariant sparse representation of the data is learned using many subjects and then the transformation into that space is applied to new subjects, and the technique of stationary subspace analysis [24], [25], which attempts to find a stationary subspace of the data from multiple subjects and/or sessi…”
BackgroundMultisource Transfer Learning for Cross-Subject EEG Emotion Recognition
Li, J., Qiu, S., Shen, Y.-Y., Liu, C.-L., & He, H. (2019) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2019.2904052 · Cited by 353
Performance variation in motor imagery brain–computer interface: A brief review
Ahn, M., & Jun, S. C. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.01.033 · Cited by 316
Internal Feature Selection Method of CSP Based on L1-Norm and Dempster–Shafer Theory
Jin, J., Xiao, R., Daly, I., Miao, Y., Wang, X., & Cichocki, A. (2021) · IEEE Transactions on Neural Networks and Learning Systems · doi:10.1109/tnnls.2020.3015505 · Cited by 267
Signal processing techniques for motor imagery brain computer interface: A review
Aggarwal, S., & Chugh, N. (2019) · Array · doi:10.1016/j.array.2019.100003 · Cited by 223
Transferring Subspaces Between Subjects in Brain--Computer Interfacing
Samek, W., Meinecke, F. C., & Muller, K.-R. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2253608 · Cited by 217
“The idea of an invariant feature space was proposed in [17] and was adapted in [15] where the authors introduce a stationary version of CSP to trade off stationarity and”
BackgroundMethodSelf-citationProbabilistic Common Spatial Patterns for Multichannel EEG Analysis
Wu, W., Chen, Z., Gao, X., Li, Y., Brown, E. N., & Gao, S. (2015) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2014.2330598 · Cited by 194
“Alternatively, the non-stationarity issue has also been addressed within a regularization framework in [32], [33], and via a cluster-based approach in [34].”
Ahn, M., Lee, M., Choi, J., & Jun, S. (2014) · Sensors · doi:10.3390/s140814601 · Cited by 186
“Hardware companies have released both inexpensive and sophisticated EEG headsets [18] and researchers have reported the development of new signal processing algorithms [27,42] that reduce calibration time [43–46] and improve accuracy [47–51].”
BackgroundEEG feature comparison and classification of simple and compound limb motor imagery
Yi, W., Qiu, S., Qi, H., Zhang, L., Wan, B., & Ming, D. (2013) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-10-106 · Cited by 183
“Otherwise, the sCSP aims at extracting robust and stationary features [28], where the penalty term”
BackgroundMethodInfluentialZich, C., Debener, S., Kranczioch, C., Bleichner, M. G., Gutberlet, I., & De Vos, M. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.04.020 · Cited by 180
“Although CSP has been established as the state-of-the-art spatial filter in MI applications, one disadvantage of CSP is its non-robustness (Samek et al., 2012), which is why current source density (CSD) (Tenke and Kayser, 2012) was calculated for the obtained EEG segments.”
MethodLotte, F. (2014) · Guide to Brain-Computer Music Interfacing · doi:10.1007/978-1-4471-6584-2_7 · Cited by 178
“It should also be mentioned that other interesting penalty terms have been proposed, in order to deal with known noise sources (Blankertz et al, 2008a), non-stationarities (Samek et al, 2012) or to perform simultaneous channel selection (Farquhar et al, 2006) (Arvaneh et al, 2011).”
BackgroundPark, S.-H., Lee, D., & Lee, S.-G. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2757519 · Cited by 170
“Therefore, classification of EEGs is a difficult task [10], [11].”
BackgroundStatthaler, K., Schwarz, A., Steyrl, D., Kobler, R., Höller, M. K., Brandstetter, J., Hehenberger, L., Bigga, M., & Müller-Putz, G. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0344-9 · Cited by 24
“Other studies reported similar shifts between calibration and feedback runs [37, 42].”
BackgroundResult
Metadata
- Authors
- Samek, W., Vidaurre, C., Müller, K.-R., & Kawanabe, M.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2012-02-20
- Volume
- 9
- Issue
- 2
- Pages
- 026013
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2047545657
- Cited by
- 213
- References
- 43
- FWCI
- 11.98
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.