A comparison of classification techniques for a gaze-independent P300-based brain–computer interface
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
This off-line study aims to assess the performance of five classifiers commonly used in the brain-computer interface (BCI) community, when applied to a gaze-independent P300-based BCI. In particular, we compared the results of four linear classifiers and one nonlinear: Fisher's linear discriminant analysis (LDA), stepwise linear discriminant analysis (SWLDA), Bayesian linear discriminant analysis (BLDA), linear support vector machine (LSVM) and Gaussian supported vector machine (GSVM). Moreover, different values for the decimation of the training dataset were tested. The results were evaluated both in terms of accuracy and written symbol rate with the data of 19 healthy subjects. No significant differences among the considered classifiers were found. The optimal decimation factor spanned a range from 3 to 24 (12 to 94 ms long bins). Nevertheless, performance on individually optimized classification parameters is not significantly different from a classification with general parameters (i.e. using an LDA classifier, about 48 ms long bins).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228 · cited 1×
“(Some figures may appear in colour only in the online journal)”
A review of classification algorithms for EEG-based brain–computer interfaces
Lotte, F., Congedo, M., Lécuyer, A., Lamarche, F., & Arnaldi, B. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r01 · Cited by 2,665
An efficient P300-based brain–computer interface for disabled subjects
Hoffmann, U., Vesin, J.-M., Ebrahimi, T., & Diserens, K. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.03.005 · Cited by 859 · cited 2×
“In this work we used the algorithm described by Hoffmann et al (2008) and which was successfully used in the work of Manyakov et al (2011).”
A comparison of classification techniques for the P300 Speller
Krusienski, D. J., Sellers, E. W., Cabestaing, F., Bayoudh, S., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/4/007 · Cited by 762
A covert attention P300-based brain–computer interface: Geospell
Aloise, F., Aricò, P., Schettini, F., Riccio, A., Salinari, S., Mattia, D., Babiloni, F., & Cincotti, F. (2012) · Ergonomics · doi:10.1080/00140139.2012.661084 · Cited by 88
Self-citation
Cited by
Combrisson, E., & Jerbi, K. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.01.010 · Cited by 599
Aricò, P., Borghini, G., Di Flumeri, G., Colosimo, A., Pozzi, S., & Babiloni, F. (2016) · Progress in Brain Research · doi:10.1016/bs.pbr.2016.04.021 · Cited by 145
Self-citationDiscriminative Canonical Pattern Matching for Single-Trial Classification of ERP Components
Xiao, X., Xu, M., Jin, J., Wang, Y., Jung, T.-P., & Ming, D. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2958641 · Cited by 113
Aricò, P., Aloise, F., Schettini, F., Salinari, S., Mattia, D., & Cincotti, F. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/3/035008 · Cited by 87
Asynchronous gaze-independent event-related potential-based brain–computer interface
Aloise, F., Aricò, P., Schettini, F., Salinari, S., Mattia, D., & Cincotti, F. (2013) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2013.07.006 · Cited by 43
Self-citation
Metadata
- Authors
- Aloise, F., Schettini, F., Aricò, P., Salinari, S., Babiloni, F., & Cincotti, F.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2012-07-25
- Volume
- 9
- Issue
- 4
- Pages
- 045012
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2155435857
- Cited by
- 46
- References
- 5
- FWCI
- 3.07
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.