In vivo two-photon microscopy reveals immediate microglial reaction to implantation of microelectrode through extension of processes
Open accessAbstract
OBJECTIVE: Penetrating cortical neural probe technologies allow investigators to record electrical signals in the brain. Implantation of probes results in acute tissue damage, and microglia density increases around implanted devices over weeks. However, the mechanisms underlying this encapsulation are not well understood in the acute temporal domain. The objective here was to evaluate dynamic microglial response to implanted probes using two-photon microscopy. APPROACH: Using two-photon in vivo microscopy, cortical microglia ∼200 µm below the surface of the visual cortex were imaged every minute in mice with green fluorescent protein-expressing microglia. MAIN RESULTS: Following probe insertion, nearby microglia immediately extended processes toward the probe at (1.6 ± 1.3) µm min(-1) during the first 30-45 min, but showed negligible cell body movement for the first 6 h. Six hours following probe insertion, microglia at distances <130.0 µm (p = 0.5) from the probe surface exhibit morphological characteristics of transitional stage (T-stage) activation, similar to the microglial response observed with laser-induced blood-brain barrier damage. T-stage morphology and microglia directionality indexes were developed to characterize microglial response to implanted probes. Evidence suggesting vascular reorganization after probe insertion and distant vessel damage was also observed hours after probe insertion. SIGNIFICANCE: A precise temporal understanding of the cellular response to microelectrode implantation will facilitate the search for molecular cues initiating and attenuating the reactive tissue response.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The implant’s size and volume directly correlate with the risk of intracerebral hemorrhage and ischemic injuries (Rosidi et al., 2011), with larger implants exerting more pressure, potentially leading to vascular compression and secondary injuries (Jaquins-Gerstl and Michael, 2009; Kozai et al., 2012).”
From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Kozai et al., 2012
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
New diagnostic criteria for multiple sclerosis: Guidelines for research protocols
Poser, C. M., Paty, D. W., Scheinberg, L., McDonald, W. I., Davis, F. A., Ebers, G. C., Johnson, K. P., Sibley, W. A., Silberberg, D. H., & Tourtellotte, W. W. (1983) · Annals of Neurology · doi:10.1002/ana.410130302 · Cited by 7,384
Resting microglial cells are highly dynamic surveillants of brain parenchyma in vivo
Nimmerjahn, A., Kirchhoff, F., & Helmchen, F. (2005) · Science · doi:10.1126/science.1110647 · Cited by 5,827
Microglia: a sensor for pathological events in the CNS
Kreutzberg, G. W. (1996) · Trends in Neurosciences · doi:10.1016/0166-2236(96)10049-7 · Cited by 4,396
Deep tissue two-photon microscopy
Helmchen, F., & Denk, W. T. (2005) · Nature Methods · doi:10.1038/nmeth818 · Cited by 4,288
Synaptic Pruning by Microglia Is Necessary for Normal Brain Development
Paolicelli, R. C., Bolasco, G., Pagani, F., Maggi, L., Scianni, M., Panzanelli, P., Giustetto, M., Ferreira, T. A., Guiducci, E., Dumas, L., et al. (2011) · Science · doi:10.1126/science.1202529 · Cited by 4,244
Microglia Sculpt Postnatal Neural Circuits in an Activity and Complement-Dependent Manner
Schafer, D. P., Lehrman, E. K., Kautzman, A. G., Koyama, R., Mardinly, A. R., Yamasaki, R., Ransohoff, R. M., Greenberg, M. E., Barres, B. A., & Stevens, B. (2012) · Neuron · doi:10.1016/j.neuron.2012.03.026 · Cited by 4,089
ATP mediates rapid microglial response to local brain injury in vivo
Davalos, D., Grutzendler, J., Yang, G., Kim, J. V., Zuo, Y., Jung, S., Littman, D. R., Dustin, M. L., & Gan, W.-B. (2005) · Nature Neuroscience · doi:10.1038/nn1472 · Cited by 3,913
Nonlinear magic: multiphoton microscopy in the biosciences
Zipfel, W. R., Williams, R. M., & Webb, W. W. (2003) · Nature Biotechnology · doi:10.1038/nbt899 · Cited by 3,911
Microglia: Active sensor and versatile effector cells in the normal and pathologic brain
Hanisch, U.-K., & Kettenmann, H. (2007) · Nature Neuroscience · doi:10.1038/nn1997 · Cited by 3,676
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
Research works printed but not linked: 4
- Betz A L, 1989, Cerebrovasc. Brain Metab. Rev., 1, 133
- Gilgunn P J Khilwani R Kozai T D Y Weber D J Cui X T Erdos G Ozdoganlar O B Fedder G K, 2012, 25th Int. Conf. on Micro Electro Mechanical Systems (MEMS), IEEE 2012, 56
- Kozai T D Y, 2010, J. Neural Eng., 7
- Nimmerjahn A, 2012, Cold Spring Harb. Protoc.
Cited by
Sorted by citations
Items 201–215 of 215
Chiprés-Tinajero, G. A., Núñez-Ochoa, M. A., & Medina‐Ceja, L. (2020) · Behavioural Neurology · doi:10.1155/2020/4385706
Coatings for Microneural Implants: Biological and Mechanical Considerations
Olczak, K. P., & Otto, K. J. (2021) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_132-1 · Cited by 1
Alba, N. A. (2013) · D-Scholarship@Pitt (University of Pittsburgh)
Coatings for Microneural Implants: Biological and Mechanical Considerations
Olczak, K. P., & Otto, K. J. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_132
Positron emission tomography imaging of neuroinflammation
(2023) · Advances in magnetic resonance technology and applications · doi:10.1016/b978-0-323-91771-1.00007-1
Chen, K., Forrest, A., González‐Burgos, G., & Kozai, T. D. Y. (2023) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2023.11.06.565852
Self-citationMcNamara, I., Wellman, S. M., Li, L., Eles, J. R., Savya, S. P., Sohal, H. S., Angle, M. R., & Kozai, T. D. Y. (2023) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2023.11.22.568119
Self-citationConductive-Hydrogel-Based Electrodes for Invasive Neural Interfaces
Кириллова, Д. А., Шарикова, Н. А., Romanov, A. O., Vasilov, R. G., Grigoriev, T. Е., & Gotovtsev, P. M. (2024) · Nanobiotechnology Reports · doi:10.1134/s2635167624602535
Flexible thin-film Implant with Depth Selectivity for Intraspinal MicrostimulationPreprint
Mirkiani, S., Matter, L., Arefadib, A., Sari, K., Tyreman, N., Asplund, M., & Mushahwar, V. K. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.02.23.707511
Poulkouras, R. (2022) · theses.fr (ABES) · doi:10.70675/18e3c078z78a1z4e5czbd7dz301fcc213f06
Aoyama, B., Nishitani, S., Yamanishi, K., Nguyen, H. D., Sakuma, R., Ishii, T., Ikeda, Y., Nishiguchi, T., Genc, I., Phuong, N. J., et al. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.05.19.726175
He, Z., Ma, J., Liu, Y., & Du, Z. J. (2026) · International Journal of Molecular Sciences · doi:10.3390/ijms27156752 · Cited by 1
Kristiansen, A. (2026) · Research Square · doi:10.21203/rs.3.rs-10977875/v1
Vreeland, R. F. (2015) · UA Campus Repository (The University of Arizona)
Metadata
- Authors
- Kozai, T. D. Y., Vazquez, A. L., Weaver, C. L., Kim, S.-G., & Cui, X. T.
- Affiliations
- University of Pittsburgh (US)
- Corresponding author
- Kozai, Takashi D Yoshida
- Cui, X Tracy
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2012-10-17
- Volume
- 9
- Issue
- 6
- Pages
- 066001
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- PMC
- PMC3511663
- OpenAlex
- W2050826469
- Cited by
- 215
- References
- 85
- Citations by year
- 2026: 13 · 2025: 12 · 2024: 20 · 2023: 21 · 2022: 16 · 2021: 19 · 2020: 19 · 2019: 15 · 2018: 16 · 2017: 17 · 2016: 15 · 2015: 15 · 2014: 12 · 2013: 3 · 2012: 1
- FWCI
- 4.09
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institutes of Health
- National Institute of Neurological Disorders and Stroke (5R01NS44589, R01NS044589, R01NS062019, K01NS066131)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Neurology › Neuroinflammation and Neurodegeneration Mechanisms
- Health Sciences › Medicine › Clinical Neurology › Traumatic Brain Injury and Neurovascular Disturbances
- Keywords
- microglia, microglial activation, visual cortex, two-photon microscopy, neuroprosthetics
- MeSH terms
- Algorithms, Animals, Blood-Brain Barrier, Brain, Craniotomy, Data Interpretation, Statistical, Electrodes, Implanted, Image Processing, Computer-Assisted, Mice, Transgenic, Microelectrodes, Microscopy, Visual Cortex, Microglia, Photons, Green Fluorescent Proteins, Mice
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review