Artifact removal from EEG signals using adaptive filters in cascade
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Artifacts in EEG (electroencephalogram) records are caused by various factors, like line interference, EOG (electro-oculogram) and ECG (electrocardiogram). These noise sources increase the difficulty in analyzing the EEG and to obtaining clinical information. For this reason, it is necessary to design specific filters to decrease such artifacts in EEG records. In this paper, a cascade of three adaptive filters based on a least mean squares (LMS) algorithm is proposed. The first one eliminates line interference, the second adaptive filter removes the ECG artifacts and the last one cancels EOG spikes. Each stage uses a finite impulse response (FIR) filter, which adjusts its coefficients to produce an output similar to the artifacts present in the EEG. The proposed cascade adaptive filter was tested in five real EEG records acquired in polysomnographic studies. In all cases, line-frequency, ECG and EOG artifacts were attenuated. It is concluded that the proposed filter reduces the common artifacts present in EEG signals without removing significant information embedded in these records.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
(1991) · Springer eBooks · doi:10.1007/978-3-7091-2840-4 · Cited by 5,095
Alexander, S. T. (1986) · Springer eBooks · doi:10.1007/978-1-4612-4978-8 · Cited by 2,646
Bioelectrical Signal Processing in Cardiac and Neurological Applications
(2005) · Elsevier eBooks · doi:10.1016/b978-0-12-437552-9.x5000-4 · Cited by 993 · cited 1×
“Other artifact sources are the ECG (electrocardiogram), EMG (electromyogram) and the power line interference (50 or 60 Hz) [3].”
BackgroundBiomedical Digital Signal Processing
Tompkins, W. J. (1993) · Cited by 402
Biosignal and Medical Image Processing
Semmlow, J. L. (2008) · CRC Press eBooks · doi:10.1201/9780203024058 · Cited by 312
Atlas and classification of electroencephalography
Torres, F. (2000) · Pediatric Neurology · doi:10.1016/s0887-8994(00)00118-1 · Cited by 89 · cited 1×
“Such rhythms are analyzed by physicians in order to detect neural disorders and cerebral pathologies [2].”
BackgroundAtlas and Classification of Electroencephalography
Lüders, H. O., & Noachtar, S. (2000) · Medical Entomology and Zoology · Cited by 65
Cited by
EEG artifact removal—state-of-the-art and guidelines
Urigüen, J. A., & Garcia-Zapirain, B. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/3/031001 · Cited by 963
Application of entropies for automated diagnosis of epilepsy using EEG signals: A review
Acharya, U. R., Fujita, H., Sudarshan, V. K., Bhat, S., & Koh, J. E. W. (2015) · Knowledge-Based Systems · doi:10.1016/j.knosys.2015.08.004 · Cited by 492
EEG-based workers' stress recognition at construction sites
Jebelli, H., Hwang, S., & Lee, S. (2018) · Automation in Construction · doi:10.1016/j.autcon.2018.05.027 · Cited by 339
A comparative review on sleep stage classification methods in patients and healthy individuals
Boostani, R., Karimzadeh, F., & Nami, M. (2017) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2016.12.004 · Cited by 316
Hussein, R., Palangi, H., Ward, R. K., & Wang, Z. J. (2019) · Clinical Neurophysiology · doi:10.1016/j.clinph.2018.10.010 · Cited by 263
Frantzidis, C. A., Bratsas, C., Papadelis, C. L., Konstantinidis, E., Pappas, C., & Bamidis, P. D. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2010.2041553 · Cited by 247
“The ocular artifacts were then removed by using an adaptive filter based on the least mean squares (LMS) algorithm [38].”
MethodSleep scoring using artificial neural networks
Ronzhina, M., Janoušek, O., Kolářová, J., Nováková, M., Honzík, P., & Provazník, I. (2012) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2011.06.003 · Cited by 229
Identification and Removal of Physiological Artifacts From Electroencephalogram Signals: A Review
Mannan, M. M. N., Kamran, M. A., & Jeong, M. Y. (2018) · IEEE Access · doi:10.1109/access.2018.2842082 · Cited by 222
“For instance, EOG signals can be used to remove ocular artifacts from EEG data [47] and/or ECG can be used to measure the reference signal that can be used to remove cardiac artifacts [48].”
BackgroundMethodMotion artefact management for soft bioelectronics
Yin, J., Wang, S., Tat, T., & Chen, J. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00175-4 · Cited by 220
“For example, through well-designed cascade-adaptive finite impulse response filters, ECG, EOG and EMG artefacts in EEG records can be considerably attenuated without compromising the core information embedded in these EEG signals 164,165 .”
Brainwave-driven human-robot collaboration in construction
Liu, Y., Habibnezhad, M., & Jebelli, H. (2021) · Automation in Construction · doi:10.1016/j.autcon.2021.103556 · Cited by 187
Metadata
- Authors
- Correa, A. G., Laciar, E., Patiño, H. D., & Valentinuzzi, M. E.
- Venue
- Journal of Physics: Conference Series
- Publisher
- IOP Publishing
- Published
- 2007-11-01
- Volume
- 90
- Pages
- 012081
- ISSN
- 1742-6588 (ISSN-L)
- 1742-6596
- OpenAlex
- W2166306684
- Cited by
- 186
- References
- 8
- FWCI
- 5.09
- Type
- conference paper
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.