The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Identification and Removal of Physiological Artifacts From Electroencephalogram Signals: A Review
Open accessAbstract
Electroencephalogram (EEG), boasting the advantages of portability, low cost, and hightemporal resolution, is a non-invasive brain-imaging modality that can be used to measure different brain states. However, EEG recordings are always contaminated with artifacts from different sources other than neurons, which renders EEG data analysis more difficult, and which potentially results in misleading findings. Therefore, it is essential for many medical and practical applications to remove these artifacts in the preprocessing stage before analyzing EEG data. In the last thirty years, various methods have been developed to remove different types of artifacts from contaminated EEG data; still though, there is no standard method that can be used optimally, and therefore, the research remains attractive as well as challenging. This paper presents an extensive overview of the existing methods for ocular, muscle, and cardiac artifact identification and removal with their comparative advantages and limitations. We also reviewed the schemes developed for validating the performances of algorithms with simulated and real EEG data. In future studies, researchers should focus not only on the combining of different methods with multiple processing stages for efficient removal of artifactual interferences but also on the development of standard criteria for validation of recorded EEG signals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Delorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371
A new method for off-line removal of ocular artifact
Gratton, G., Coles, M. G. H., & Donchin, E. (1983) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(83)90135-9 · Cited by 5,055
Van Veen, B. D., Van Drongelen, W., Yuchtman, M., & Suzuki, A. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.623056 · Cited by 2,561
Delorme, A., Sejnowski, T., & Makeig, S. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.11.004 · Cited by 1,759 · cited 24×
“Even though ICA is successfully used to remove muscle artifacts [120], [130], it is, unlike the case of EOG artifact removal, very difficult to separate muscle artifacts in different ICs, due to the fact that these artifacts are superimposed onto some ICs [104], [113], [114], [232].”
MethodInfluentialIndependent EEG Sources Are Dipolar
Delorme, A., Palmer, J., Onton, J., Oostenveld, R., & Makeig, S. (2012) · PLoS ONE · doi:10.1371/journal.pone.0030135 · Cited by 810
High-Frequency Brain Activity and Muscle Artifacts in MEG/EEG: A Review and Recommendations
Muthukumaraswamy, S. D. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00138 · Cited by 697
Suppression of Interference and Artifacts by the Signal Space Separation Method
Taulu, S., Kajola, M., & Simola, J. (2004) · Brain Topography · doi:10.1023/b:brat.0000032864.93890.f9 · Cited by 541
FORCe: Fully online and automated artifact removal for brain-computer interfacing
Daly, I., Scherer, R., Billinger, M., & Muller-Putz, G. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2346621 · Cited by 174
Cited by
Machine Learning for Predicting Epileptic Seizures Using EEG Signals: A Review
Rasheed, K., Qayyum, A., Qadir, J., Sivathamboo, S., Kwan, P., Kuhlmann, L., O'Brien, T., & Razi, A. (2021) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2020.3008792 · Cited by 409
Chuang, C.-H., Chang, K.-Y., Huang, C.-S., & Jung, T.-P. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.119586 · Cited by 88
Metadata
- Authors
- Mannan, M. M. N., Kamran, M. A., & Jeong, M. Y.
- Venue
- IEEE Access
- Published
- 2018
- Volume
- 6
- Pages
- 30630-30652
- ISSN
- 2169-3536 (ISSN-L)
- OpenAlex
- W2806000515
- Cited by
- 222
- References
- 8
- FWCI
- 8.71
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Identification and Removal of Physiological Artifacts From Electroencephalogram Signals: A Review. https://app.cochat.ai/papers/10.1109/access.2018.2842082
- The paper
- Mannan, M. M. N., Kamran, M. A., & Jeong, M. Y. (2018). Identification and Removal of Physiological Artifacts From Electroencephalogram Signals: A Review. IEEE Access. https://doi.org/10.1109/access.2018.2842082
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.