Microfluidic system for modelling 3D tumour invasion into surrounding stroma and drug screening
Open accessThe DOI matches its Crossref record; 55 of the 56 references it cites were found in a registry or an index.
Abstract
Tumour invasion into the surrounding stroma is a critical step in metastasis, and it is necessary to clarify the role of microenvironmental factors in tumour invasion. We present a microfluidic system that simulated and controlled multi-factors of the tumour microenvironment for three-dimensional (3D) assessment of tumour invasion into the stroma. The simultaneous, precise and continuous arrangement of two 3D matrices was visualised to observe the migration of cancer cell populations or single cells by transfecting cells with a fluorescent protein. A vascular endothelial layer was formed to simulate transendothelial transport of nutrients, and its endothelial barrier function was verified by the diffusion of 70 kDa fluorescein isothiocyanate (FITC)-Dextran in 3D matrices. Through high-throughput cell migration tracking observation and statistic evaluation, we clarified that cell density of the tumour directly determined its invasiveness. The results suggested that increased secretion of IL-6 among both cancer cells (MDA-MB-231) and noncancerous cells (MCF-10A or HDF-n) after co-culture contributes to cancer cell invasiveness, and this was verified by an IL-6 inhibitor assay. Finally, the drug efficacy of paclitaxel was reflected as changes in cancer cell migration ability, viability, and morphology. Together, our microfluidic devices could be a useful tool to study the mechanism of tumour invasion into the stroma and to screen anti-metastatic drugs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“It was observed that direct interaction with rat neural cells was responsible for low permeability.”
From 3D Biomimetic Models to Reconstitute Tumor Microenvironment In Vitro: Spheroids, Organoids, and Tumor‐on‐a‐Chip (2023) · cites this paper as [148]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hallmarks of Cancer: The Next Generation
Hanahan, D., & Weinberg, R. A. (2011) · Cell · doi:10.1016/j.cell.2011.02.013 · Cited by 66,590
Microenvironmental regulation of tumor progression and metastasis
Quail, D. F., & Joyce, J. A. (2013) · Nature Medicine · doi:10.1038/nm.3394 · Cited by 7,994
A Perspective on Cancer Cell Metastasis
Chaffer, C. L., & Weinberg, R. A. (2011) · Science · doi:10.1126/science.1203543 · Cited by 4,807
Tumor Metastasis: Molecular Insights and Evolving Paradigms
Valastyan, S., & Weinberg, R. A. (2011) · Cell · doi:10.1016/j.cell.2011.09.024 · Cited by 4,011
Soft Lithography in Biology and Biochemistry
Whitesides, G. M., Ostuni, E., Takayama, S., Jiang, X., & Ingber, D. E. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.335 · Cited by 2,607
Poly(dimethylsiloxane) as a Material for Fabricating Microfluidic Devices
McDonald, J. C., & Whitesides, G. M. (2002) · Accounts of Chemical Research · doi:10.1021/ar010110q · Cited by 2,454
Diagnosing the decline in pharmaceutical R&D efficiency
Scannell, J. W., Blanckley, A., Boldon, H., & Warrington, B. (2012) · Nature Reviews Drug Discovery · doi:10.1038/nrd3681 · Cited by 1,981
Cancer Invasion and the Microenvironment: Plasticity and Reciprocity
Friedl, P., & Alexander, S. (2011) · Cell · doi:10.1016/j.cell.2011.11.016 · Cited by 1,940
Stochastic State Transitions Give Rise to Phenotypic Equilibrium in Populations of Cancer Cells
Gupta, P. B., Fillmore, C. M., Jiang, G., Shapira, S. D., Tao, K., Kuperwasser, C., & Lander, E. S. (2011) · Cell · doi:10.1016/j.cell.2011.07.026 · Cited by 1,475
Organs-on-chips at the frontiers of drug discovery
Esch, E. W., Bahinski, A., & Huh, D. (2015) · Nature Reviews Drug Discovery · doi:10.1038/nrd4539 · Cited by 1,185
Cited by
3D Bioprinted in vitro metastatic models via reconstruction of tumor microenvironments
Meng, F., Meyer, C. M., Joung, D., Vallera, D. A., McAlpine, M. C., & Panoskaltsis‐Mortari, A. (2019) · Advanced Materials · doi:10.1002/adma.201806899 · Cited by 262
Organ-on-a-chip meets artificial intelligence in drug evaluation
Deng, S., Li, C., Cao, J., Cui, Z., Du, J., Fu, Z., Yang, H., & Chen, P. (2023) · Theranostics · doi:10.7150/thno.87266 · Cited by 260
Organs-on-chips technologies – A guide from disease models to opportunities for drug development
Monteduro, A. G., Rizzato, S., Caragnano, G., Trapani, A., Giannelli, G., & Maruccio, G. (2023) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2023.115271 · Cited by 175
Li, W., Zhou, Z., Zhou, X., Khoo, B. L., Gunawan, R., Chin, Y. R., Zhang, L., Yi, C., Guan, X., & Yang, M. (2023) · Advanced Healthcare Materials · doi:10.1002/adhm.202202609 · Cited by 119
Jia, L., Han, F., Yang, H., Turnbull, G. S., Wang, J., Clarke, J., Shu, W., Guo, M., & Li, B. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201900435 · Cited by 118
Metadata
- Authors
- Du, Z., Mi, S., Yi, X., Xu, Y., & Sun, W.
- Affiliations
- Tsinghua Shenzhen International Graduate School (CN)
- Tsinghua–Berkeley Shenzhen Institute (CN)
- Corresponding author
- Sun, Wei
- Venue
- Biofabrication
- Publisher
- IOP Publishing
- Published
- 2018-06-06
- Volume
- 10
- Issue
- 3
- Pages
- 034102
- ISSN
- 1758-5082 (ISSN-L)
- 1758-5090
- OpenAlex
- W2804297698
- Cited by
- 42
- References
- 56
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 3 · 2023: 12 · 2022: 6 · 2021: 3 · 2020: 4 · 2019: 9 · 2018: 2
- FWCI
- 1.80
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- publishingsupport.iopscience.iop.org/iop-standard/v1 (vor)
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- Locations
- Biofabrication (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Health Sciences › Medicine › Oncology › Cancer Cells and Metastasis
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Keywords
- tumor invasion, tumor stroma, microfluidics, tumor microenvironment, tumor cell migration, endothelial barrier function, transendothelial transport, interleukin-6, co-culture, paclitaxel, 3D cell culture, metastasis
- MeSH terms
- Antineoplastic Agents, Cell Survival, Drug Evaluation, Preclinical, Humans, Coculture Techniques, Tissue Engineering, Cell Line, Tumor, Microfluidic Analytical Techniques, Tumor Microenvironment, Human Umbilical Vein Endothelial Cells
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.