The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Tissue-Engineered Vascular Autograft: Inferior Vena Cava Replacement in a Dog Model
Abstract
Tissue-engineered vascular autografts (TEVAs) were made by seeding 4-6 x 10(6) of mixed cells obtained from femoral veins of mongrel dogs onto tube-shaped biodegradable polymer scaffolds composed of a polyglycolid acid (PGA) nonwoven fabric sheet and a copolymer of L-lactide and caprolactone (n = 4). After 7 days, the inferior vena cavas (IVCs) of the same dogs were replaced with TEVAs. After 3, 4, 5, and 6 months, angiographies were performed, and the dogs were sacrificed. The implanted TEVAs were examined both grossly and immunohistologically. The implanted TEVAs showed no evidence of stenosis or dilatation. No thrombus was found inside the TEVAs, even without any anticoagulation therapy. Remnants of the polymer scaffolds were not observed in all specimens, and the overall gross appearance similar to that of native IVCs. Immunohistological staining revealed the presence of factor VIII positive nucleated cells at the luminal surface of the TEVAs. In addition, lesions were observed where alpha-smooth muscle actin and desmin positive cells existed. Implanted TEVAs contained a sufficient amount of extracellular matrix, and showed neither occlusion nor aneurysmal formation. In addition, endothelial cells were found to line the luminal surface of each TEVA. These results strongly suggest that "ideal" venous grafts with antithrombogenicity can be produced.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Langer, R., & Vacanti, J. P. (1993) · Science · doi:10.1126/science.8493529 · Cited by 9,893
Langer, R. (1990) · Science · doi:10.1126/science.2218494 · Cited by 1,778
Cited by
Aligned biodegradable nanofibrous structure: a potential scaffold for blood vessel engineering
Xu, C. Y., Inai, R., Kotaki, M., & Ramakrishna, S. (2004) · Biomaterials · doi:10.1016/s0142-9612(03)00593-3 · Cited by 1,213
Challenges in tissue engineering
Ikada, Y. (2006) · Journal of The Royal Society Interface · doi:10.1098/rsif.2006.0124 · Cited by 919
Self-citationElectrospun nanofiber scaffolds: engineering soft tissues
Kumbar, S. G., James, R., Nukavarapu, S. P., & Laurencin, C. T. (2008) · Biomedical Materials · doi:10.1088/1748-6041/3/3/034002 · Cited by 598
Shin’oka, T., Matsumura, G., Hibino, N., Naito, Y., Watanabe, M., Konuma, T., Sakamoto, T., Nagatsu, M., & Kurosawa, H. (2005) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2004.12.047 · Cited by 585
Self-citationRoh, J. D., Sawh-Martinez, R., Brennan, M. P., Jay, S. M., Devine, L., Rao, D. A., Yi, T., Mirensky, T. L., Nalbandian, A., Udelsman, B., et al. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0911465107 · Cited by 559
Self-citation
Metadata
- Authors
- Watanabe, M., Shin'oka, T., Tohyama, S., Hibino, N., Konuma, T., Matsumura, G., Kosaka, Y., Ishida, T., Imai, Y., Yamakawa, M., Ikada, Y., & Morita, S.
- Venue
- Tissue Engineering
- Publisher
- SAGE Publications
- Published
- 2001-08
- Volume
- 7
- Issue
- 4
- Pages
- 429-439
- ISSN
- 1076-3279 (ISSN-L)
- 1557-8690
- OpenAlex
- W1991164652
- Cited by
- 215
- References
- 2
- FWCI
- 6.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tissue-Engineered Vascular Autograft: Inferior Vena Cava Replacement in a Dog Model. https://app.cochat.ai/papers/10.1089/10763270152436481
- The paper
- Watanabe, M., Shin'oka, T., Tohyama, S., Hibino, N., Konuma, T., Matsumura, G., Kosaka, Y., Ishida, T., Imai, Y., Yamakawa, M., Ikada, Y., & Morita, S. (2001). Tissue-Engineered Vascular Autograft: Inferior Vena Cava Replacement in a Dog Model. Tissue Engineering. https://doi.org/10.1089/10763270152436481
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.