Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 215

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Tissue-Engineered Vascular Autograft: Inferior Vena Cava Replacement in a Dog Model

Watanabe, Manabu, Shin'oka, Toshiharu, Tohyama, Satoshi, Hibino, Narutoshi, Konuma, Takeshi, Matsumura, Gohki, Kosaka, Yoshimichi, Ishida, Toru, Imai, Yasuharu, Yamakawa, Mitsunori, Ikada, Yoshito, Morita, Shin'ichiro·2001·Tissue Engineering

Abstract

Tissue-engineered vascular autografts (TEVAs) were made by seeding 4-6 x 10(6) of mixed cells obtained from femoral veins of mongrel dogs onto tube-shaped biodegradable polymer scaffolds composed of a polyglycolid acid (PGA) nonwoven fabric sheet and a copolymer of L-lactide and caprolactone (n = 4). After 7 days, the inferior vena cavas (IVCs) of the same dogs were replaced with TEVAs. After 3, 4, 5, and 6 months, angiographies were performed, and the dogs were sacrificed. The implanted TEVAs were examined both grossly and immunohistologically. The implanted TEVAs showed no evidence of stenosis or dilatation. No thrombus was found inside the TEVAs, even without any anticoagulation therapy. Remnants of the polymer scaffolds were not observed in all specimens, and the overall gross appearance similar to that of native IVCs. Immunohistological staining revealed the presence of factor VIII positive nucleated cells at the luminal surface of the TEVAs. In addition, lesions were observed where alpha-smooth muscle actin and desmin positive cells existed. Implanted TEVAs contained a sufficient amount of extracellular matrix, and showed neither occlusion nor aneurysmal formation. In addition, endothelial cells were found to line the luminal surface of each TEVA. These results strongly suggest that "ideal" venous grafts with antithrombogenicity can be produced.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/10763270152436481

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 215

Metadata

Authors
Watanabe, M., Shin'oka, T., Tohyama, S., Hibino, N., Konuma, T., Matsumura, G., Kosaka, Y., Ishida, T., Imai, Y., Yamakawa, M., Ikada, Y., & Morita, S.
Venue
Tissue Engineering
Published
2001-08
Volume
7
Issue
4
Pages
429-439
ISSN
  • 1076-3279 (ISSN-L)
  • 1557-8690
OpenAlex
W1991164652
Cited by
215
References
2
FWCI
6.83
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Tissue-Engineered Vascular Autograft: Inferior Vena Cava Replacement in a Dog Model. https://app.cochat.ai/papers/10.1089/10763270152436481
The paper
Watanabe, M., Shin'oka, T., Tohyama, S., Hibino, N., Konuma, T., Matsumura, G., Kosaka, Y., Ishida, T., Imai, Y., Yamakawa, M., Ikada, Y., & Morita, S. (2001). Tissue-Engineered Vascular Autograft: Inferior Vena Cava Replacement in a Dog Model. Tissue Engineering. https://doi.org/10.1089/10763270152436481

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.