Tissue-Engineered Vascular Autograft: Inferior Vena Cava Replacement in a Dog Model
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Tissue-engineered vascular autografts (TEVAs) were made by seeding 4-6 x 10(6) of mixed cells obtained from femoral veins of mongrel dogs onto tube-shaped biodegradable polymer scaffolds composed of a polyglycolid acid (PGA) nonwoven fabric sheet and a copolymer of L-lactide and caprolactone (n = 4). After 7 days, the inferior vena cavas (IVCs) of the same dogs were replaced with TEVAs. After 3, 4, 5, and 6 months, angiographies were performed, and the dogs were sacrificed. The implanted TEVAs were examined both grossly and immunohistologically. The implanted TEVAs showed no evidence of stenosis or dilatation. No thrombus was found inside the TEVAs, even without any anticoagulation therapy. Remnants of the polymer scaffolds were not observed in all specimens, and the overall gross appearance similar to that of native IVCs. Immunohistological staining revealed the presence of factor VIII positive nucleated cells at the luminal surface of the TEVAs. In addition, lesions were observed where alpha-smooth muscle actin and desmin positive cells existed. Implanted TEVAs contained a sufficient amount of extracellular matrix, and showed neither occlusion nor aneurysmal formation. In addition, endothelial cells were found to line the luminal surface of each TEVA. These results strongly suggest that "ideal" venous grafts with antithrombogenicity can be produced.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Langer, R., & Vacanti, J. P. (1993) · Science · doi:10.1126/science.8493529 · Cited by 9,893
Langer, R. (1990) · Science · doi:10.1126/science.2218494 · Cited by 1,778
Cited by
Aligned biodegradable nanofibrous structure: a potential scaffold for blood vessel engineering
Xu, C. Y., Inai, R., Kotaki, M., & Ramakrishna, S. (2004) · Biomaterials · doi:10.1016/s0142-9612(03)00593-3 · Cited by 1,213
Challenges in tissue engineering
Ikada, Y. (2006) · Journal of The Royal Society Interface · doi:10.1098/rsif.2006.0124 · Cited by 919
Self-citationElectrospun nanofiber scaffolds: engineering soft tissues
Kumbar, S. G., James, R., Nukavarapu, S. P., & Laurencin, C. T. (2008) · Biomedical Materials · doi:10.1088/1748-6041/3/3/034002 · Cited by 598
Shin’oka, T., Matsumura, G., Hibino, N., Naito, Y., Watanabe, M., Konuma, T., Sakamoto, T., Nagatsu, M., & Kurosawa, H. (2005) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2004.12.047 · Cited by 585
Self-citationRoh, J. D., Sawh-Martinez, R., Brennan, M. P., Jay, S. M., Devine, L., Rao, D. A., Yi, T., Mirensky, T. L., Nalbandian, A., Udelsman, B., et al. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0911465107 · Cited by 559
Self-citationLate-term results of tissue-engineered vascular grafts in humans
Hibino, N., McGillicuddy, E., Matsumura, G., Ichihara, Y., Naito, Y., Breuer, C., & Shinoka, T. (2010) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2009.09.057 · Cited by 520
Self-citationSmall-Diameter Artificial Arteries Engineered In Vitro
Isenberg, B. C., Williams, C., & Tranquillo, R. T. (2006) · Circulation Research · doi:10.1161/01.res.0000196867.12470.84 · Cited by 469
Vaz, C. M., van Tuijl, S., Bouten, C. V. C., & Baaijens, F. P. T. (2005) · Acta Biomaterialia · doi:10.1016/j.actbio.2005.06.006 · Cited by 459
Xu, C., Inai, R., Kotaki, M., & Ramakrishna, S. (2004) · Tissue Engineering · doi:10.1089/1076327041887736 · Cited by 399
Biomaterials for Vascular Tissue Engineering
Ravi, S., & Chaikof, E. L. (2010) · Regenerative Medicine · doi:10.2217/rme.09.77 · Cited by 387
Bio-CAD modeling and its applications in computer-aided tissue engineering
Sun, W., Starly, B., Nam, J., & Darling, A. (2005) · Computer-Aided Design · doi:10.1016/j.cad.2005.02.002 · Cited by 386
Computer‐aided tissue engineering: overview, scope and challenges
Sun, W., Darling, A., Starly, B., & Nam, J. (2004) · Biotechnology and Applied Biochemistry · doi:10.1042/ba20030108 · Cited by 341
Artificial blood vessel: The Holy Grail of peripheral vascular surgery
Kakisis, J. D., Liapis, C. D., Breuer, C., & Sumpio, B. E. (2005) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2004.12.026 · Cited by 310
Successful application of tissue engineered vascular autografts: clinical experience
Matsumura, G., Hibino, N., Ikada, Y., Kurosawa, H., & Shin’oka, T. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00043-7 · Cited by 276
Self-citationMatsumura, G., Miyagawa-Tomita, S., Shin’oka, T., Ikada, Y., & Kurosawa, H. (2003) · Circulation · doi:10.1161/01.cir.0000092165.32213.61 · Cited by 275
Self-citationTissue Engineering and Regenerative Medicine: Concepts for Clinical Application
Atala, A. (2004) · Rejuvenation Research · doi:10.1089/154916804323105053 · Cited by 217
“120 121–125 The key advantage of using these autografts is that they degrade in vivo , and thus allow the new tissue to form without the longterm presence of foreign material.”
Recent concepts in biodegradable polymers for tissue engineering paradigms: a critical review
Iqbal, N., Khan, A. S., Asif, A., Yar, M., Haycock, J. W., & Rehman, I. U. (2019) · International Materials Reviews · doi:10.1080/09506608.2018.1460943 · Cited by 208
Biodegradable polyester elastomers in tissue engineering
Webb, A. R., Yang, J., & Ameer, G. A. (2004) · Expert Opinion on Biological Therapy · doi:10.1517/14712598.4.6.801 · Cited by 208
“In particular, bone marrowseeded grafts were implanted into the inferior vena cava of adult beagles [62,64].”
MethodSmall-diameter biodegradable scaffolds for functional vascular tissue engineering in the mouse model
Roh, J. D., Nelson, G. N., Brennan, M. P., Mirensky, T. L., Yi, T., Hazlett, T. F., Tellides, G., Sinusas, A. J., Pober, J. S., Saltzman, W. M., et al. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.11.041 · Cited by 192
Fusion of uniluminal vascular spheroids: A model for assembly of blood vessels
Fleming, P. A., Argraves, W. S., Gentile, C., Neagu, A., Forgacs, G., & Drake, C. J. (2010) · Developmental Dynamics · doi:10.1002/dvdy.22161 · Cited by 123
“…the use of natural or synthetic polymeric tubular scaffolds, which are seeded with ECs and SMCs (Weinberg and Bell, 1986; Niklason et al., 1999; Watanabe et al., 2001), the use of sheets of vascular cells, which are formed into tubes (L’Heureux et al., 1998, 2006), and a bioprinting approach…”
BackgroundPolymeric Materials for Tissue Engineering of Arterial Substitutes
Ravi, S., Qu, Z., & Chaikof, E. L. (2009) · Vascular · doi:10.2310/6670.2008.00084 · Cited by 91
Metadata
- Authors
- Watanabe, M., Shin'oka, T., Tohyama, S., Hibino, N., Konuma, T., Matsumura, G., Kosaka, Y., Ishida, T., Imai, Y., Yamakawa, M., Ikada, Y., & Morita, S.
- Venue
- Tissue Engineering
- Publisher
- SAGE Publications
- Published
- 2001-08
- Volume
- 7
- Issue
- 4
- Pages
- 429-439
- ISSN
- 1076-3279 (ISSN-L)
- 1557-8690
- OpenAlex
- W1991164652
- Cited by
- 215
- References
- 2
- FWCI
- 6.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.