Tissue-Engineered Scaffolds Are Effective Alternatives to Autografts for Bridging Peripheral Nerve Gaps
The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
The use of autografts for "bridging" peripheral nerve gaps is limited by lack of suitable donor nerve grafts. Using a tissue-engineering approach, we have designed a three-dimensional scaffold that presents laminin 1 (LN-1) and nerve growth factor (NGF) in vivo. Semipermeable polysulfone tubes were used as carriers to introduce the tissue-engineered scaffolds to a 10-mm sciatic nerve gap in adult rats. Two months after implantation, the gross morphology of the regenerated nerve, the success rate of regeneration, and the total number and density of myelinated axons in the tissue-engineered scaffolds matched that observed in autografts. LN-1- and NGF-containing scaffolds performed comparably to autografts when functional measures that include the relative gastrocnemius muscle weight and the sciatic functional index were quantified. Our results demonstrate that tissue-engineered scaffolds match the performance of autografts in an in vivo model of peripheral nerve regeneration, raising the possibility of the scaffolds being used clinically instead of scarce autografts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Integrins: A family of cell surface receptors
HYNES, R. (1987) · Cell · doi:10.1016/0092-8674(87)90233-9 · Cited by 4,249 · cited 1×
“32 Neurotrophic factors support growth, differentiation, and survival of neurons in the nervous system.”
The Molecular Biology of Axon Guidance
Tessier-Lavigne, M., & Goodman, C. S. (1996) · Science · doi:10.1126/science.274.5290.1123 · Cited by 3,278
Functional Evaluation of Complete Sciatic, Peroneal, and Posterior Tibial Nerve Lesions in the Rat
Bain, J. R., Mackinnon, S. E., & Hunter, D. A. (1989) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-198901000-00024 · Cited by 1,260 · cited 2×
“The sciatic functional index was calculated by using the following formula 27 : SFI 5 2 38.”
InfluentialThe cellular and molecular basis of peripheral nerve regeneration
Fu, S. Y., & Gordon, T. (1997) · Molecular Neurobiology · doi:10.1007/bf02740621 · Cited by 1,202
de Medinaceli, L., Freed, W. J., & Wyatt, R. J. (1982) · Experimental Neurology · doi:10.1016/0014-4886(82)90234-5 · Cited by 1,151 · cited 1×
“8 1 2 1 109.5 1 2 This formula was developed by De Medinaceli et al. 28 and modified by Bain et al. 27 (For a detailed description, please see the review by Varejao et al. 25 )”
InfluentialHeumann, R., Korsching, S., Bandtlow, C., & Thoenen, H. (1987) · The Journal of cell biology · doi:10.1083/jcb.104.6.1623 · Cited by 1,022 · cited 1×
“The success of Schwann cells in peripheral nerve regeneration results in part from their production of cell adhesion molecules and neurotrophic factors that mediate neurite attachment and growth, 7,8 particularly laminin 1 (LN-1) and nerve growth factor (NGF).”
Lundborg, G. (2000) · The Journal of Hand Surgery · doi:10.1053/jhsu.2000.4165 · Cited by 656 · cited 1×
“1 Therefore, it is important to develop alternative approaches for autografts.”
Mechanisms and Molecules that Control Growth Cone Guidance
Goodman, C. S. (1996) · Annual Review of Neuroscience · doi:10.1146/annurev.ne.19.030196.002013 · Cited by 521 · cited 1×
“31 Extracellu-TISSUE-ENGINEERED SCAFFOLDS BRIDGE SCIATIC NERVE GAPS lar matrix proteins affect cell interactions during the development, maintenance, and regeneration of the nervous system.”
Guenard, V, Kleitman, N., Morrissey, T., Bunge, R., & Aebischer, P. (1992) · The Journal of Neuroscience · doi:10.1523/jneurosci.12-09-03310.1992 · Cited by 474 · cited 1×
“4,5 However, high concentrations of Schwann cells (60–80 million Schwann cells/mL) are needed for functional efficacy 6 and an unacceptably long time is required to culture sufficient numbers, allowing the injury to worsen.”
Martini, R. (1994) · Journal of Neurocytology · doi:10.1007/bf01189813 · Cited by 409 · cited 1×
“10,11 However, others report that Matrigel actually impeded peripheral nerve regeneration, presumably because it contained significant amounts of inhibitory and potentially inflammatory cytokines.”
Cited by
Advantages of RGD peptides for directing cell association with biomaterials
Bellis, S. L. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.02.029 · Cited by 745
Subramanian, A., Krishnan, U. M., & Sethuraman, S. (2009) · Journal of Biomedical Science · doi:10.1186/1423-0127-16-108 · Cited by 599
Daly, W., Yao, L., Zeugolis, D., Windebank, A., & Pandit, A. (2012) · Journal of The Royal Society Interface · doi:10.1098/rsif.2011.0438 · Cited by 551
Bioactive glasses beyond bone and teeth: Emerging applications in contact with soft tissues
Miguez-Pacheco, V., Hench, L. L., & Boccaccini, A. R. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.11.004 · Cited by 544
The role of aligned polymer fiber-based constructs in the bridging of long peripheral nerve gaps
Kim, Y.-T., Haftel, V. K., Kumar, S., & Bellamkonda, R. V. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.03.042 · Cited by 451
Self-citationCurrent applications and future perspectives of artificial nerve conduits
Jiang, X., Lim, S. H., Mao, H.-Q., & Chew, S. Y. (2010) · Experimental Neurology · doi:10.1016/j.expneurol.2009.09.009 · Cited by 394
Approaches to neural tissue engineering using scaffolds for drug delivery
Willerth, S. M., & Sakiyama-Elbert, S. E. (2007) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.03.014 · Cited by 392
Aligned electrospun nanofibers specify the direction of dorsal root ganglia neurite growth
Corey, J. M., Lin, D. Y., Mycek, K. B., Chen, Q., Samuel, S., Feldman, E. L., & Martin, D. C. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31285 · Cited by 380
Pfister, B. J., Gordon, T., Loverde, J. R., Kochar, A. S., Mackinnon, S. E., & Cullen, D. K. (2011) · Critical Reviews™ in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v39.i2.20 · Cited by 358
Optimized Acellular Nerve Graft Is Immunologically Tolerated and Supports Regeneration
Hudson, T. W., Zawko, S., Deister, C., Lundy, S., Hu, C. Y., Lee, K., & Schmidt, C. E. (2004) · Tissue Engineering · doi:10.1089/ten.2004.10.1641 · Cited by 353
Get a grip: integrins in cell–biomaterial interactions
García, A. J. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.05.029 · Cited by 333
Lee, H., McKeon, R. J., & Bellamkonda, R. V. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0905437106 · Cited by 313
Self-citationJain, A., Kim, Y.-T., McKeon, R. J., & Bellamkonda, R. V. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.07.008 · Cited by 308
Self-citationGupta, D., Venugopal, J., Prabhakaran, M. P., Dev, V. R. G., Low, S., Choon, A. T., & Ramakrishna, S. (2009) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.01.039 · Cited by 295
Polysaccharides and Their Derivatives for Versatile Tissue Engineering Application
Khan, F., & Ahmad, S. R. (2013) · Macromolecular Bioscience · doi:10.1002/mabi.201200409 · Cited by 274
Dodla, M. C., & Bellamkonda, R. V. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.08.045 · Cited by 254
Self-citationOrganic electrode coatings for next-generation neural interfaces
Aregueta-Robles, U. A., Woolley, A. J., Poole-Warren, L. A., Lovell, N. H., & Green, R. A. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00015 · Cited by 254
Petrie, T. A., Capadona, J. R., Reyes, C. D., & García, A. J. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.06.027 · Cited by 238
Wang, J., Cheng, Y., Chen, L., Zhu, T., Ye, K., Jia, C., Wang, H., Zhu, M., Fan, C., & Mo, X. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.11.032 · Cited by 232
Design and preparation of polymeric scaffolds for tissue engineering
Weigel, T., Schinkel, G., & Lendlein, A. (2006) · Expert Review of Medical Devices · doi:10.1586/17434440.3.6.835 · Cited by 228
Thermoreversible laminin‐functionalized hydrogel for neural tissue engineering
Stabenfeldt, S. E., García, A. J., & LaPlaca, M. C. (2006) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30638 · Cited by 217
Sarker, M. D., Naghieh, S., McInnes, A. D., Schreyer, D. J., & Chen, X. (2018) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2018.07.002 · Cited by 198
“In addition, measured gastrocnemius muscle weight and the sciatic functional index were found similar for both LN-1/NGF conduits and autografts (Yu and Bellamkonda, 2003).”
Remote and local control of stimuli responsive materials for therapeutic applications
Chan, A., Orme, R. P., Fricker, R. A., & Roach, P. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.07.007 · Cited by 190
Xie, J., MacEwan, M. R., Liu, W., Jesuraj, N., Li, X., Hunter, D., & Xia, Y. (2014) · ACS Applied Materials & Interfaces · doi:10.1021/am5018557 · Cited by 162
Visual prosthesis: interfacing stimulating electrodes with retinal neurons to restore vision.
Barriga-Rivera, A., Bareket, L., Goding, J., Aregueta-Robles, U. A., & Suaning, G. J. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00620 · Cited by 73
“…2015a) Support neuronal differentiation Fibrin+NT3 (Taylor and Sakiyama-Elbert, 2006) Collagen+NT3(Houweling et al., 1998) Agarose +NGF and laminin (Yu and Bellamkonda, 2003) PEG-CNTF (Burdick et al., 2006) PEG-PLA +NT3(Piantino et al., 2006) +BDNF(Winter et al., 2008) +NGF(Winter et al., 2007)…”
Metadata
- Authors
- Yu, X., & Bellamkonda, R. V.
- Venue
- Tissue Engineering
- Publisher
- SAGE Publications
- Published
- 2003-06
- Volume
- 9
- Issue
- 3
- Pages
- 421-430
- ISSN
- 1076-3279 (ISSN-L)
- 1557-8690
- OpenAlex
- W2176312328
- Cited by
- 186
- References
- 36
- FWCI
- 2.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.