The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Macroporous Biphasic Calcium Phosphate Scaffold with High Permeability/Porosity Ratio
Abstract
Macroporous biphasic calcium phosphate (BCP) with channel-shaped pores was produced by a novel dual-phase mixing method. The processing route includes mixing water-based BCP slurry and polymethylmethacrylate resin; shaping in a mold; and polymerization, drying, pyrolyzing, and sintering. After comparison with two other commercial macroporous BCP materials, which were produced along different routes, it was found that conventional parameters such as porosity and pore size cannot describe a macroporous structure precisely enough for the application as tissue-engineering scaffold. Instead, permeability can be seen as an intrinsic and quantitative parameter to describe the macroporous structure of various scaffolds, because it is independent of sample size and fluid used in the test. Another parameter, the permeability/porosity ratio, provides an indication of the percolative efficiency per unit porous volume of a scaffold. Structural characterizations and permeability studies of other macroporous scaffold materials were also performed, and it was found that permeability could reflect a combination of five important parameters for scaffold: (1) porosity, (2) pore size and distribution, (3) interconnectivity, (4) fenestration size and distribution, and (5) orientation of pores. Finally, the implications of relating permeability with biological performances are also discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tissue-engineered bone regeneration
Petite, H., Viateau, V., Bensaïd, W., Meunier, A., de Pollak, C., Bourguignon, M., Oudina, K., Sedel, L., & Guillemin, G. (2000) · Nature Biotechnology · doi:10.1038/79449 · Cited by 1,475
Cited by
Bioceramics of calcium orthophosphates
Dorozhkin, S. V. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.11.050 · Cited by 1,338
Bioactive Glass and Glass-Ceramic Scaffolds for Bone Tissue Engineering
Gerhardt, L.-C., & Boccaccini, A. R. (2010) · Materials · doi:10.3390/ma3073867 · Cited by 1,179
Scaffolds for tissue fabrication
Ma, P. X. (2004) · Materials Today · doi:10.1016/s1369-7021(04)00233-0 · Cited by 1,077
Osteoinductive ceramics as a synthetic alternative to autologous bone grafting
Yuan, H., Fernandes, H., Habibovic, P., de Boer, J., Barradas, A. M. C., de Ruiter, A., Walsh, W. R., van Blitterswijk, C. A., & de Bruijn, J. D. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1003600107 · Cited by 746
Karande, T. S., Ong, J. L., & Agrawal, C. M. (2004) · Annals of Biomedical Engineering · doi:10.1007/s10439-004-7825-2 · Cited by 457
Metadata
- Authors
- Li, S., de Wijn, J. R., Li, J., Layrolle, P., & de Groot, K.
- Venue
- Tissue Engineering
- Publisher
- SAGE Publications
- Published
- 2003-06
- Volume
- 9
- Issue
- 3
- Pages
- 535-548
- ISSN
- 1076-3279 (ISSN-L)
- 1557-8690
- OpenAlex
- W2008827598
- Cited by
- 212
- References
- 1
- FWCI
- 5.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Macroporous Biphasic Calcium Phosphate Scaffold with High Permeability/Porosity Ratio. https://app.cochat.ai/papers/10.1089/107632703322066714
- The paper
- Li, S., de Wijn, J. R., Li, J., Layrolle, P., & de Groot, K. (2003). Macroporous Biphasic Calcium Phosphate Scaffold with High Permeability/Porosity Ratio. Tissue Engineering. https://doi.org/10.1089/107632703322066714
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.