Macroporous Biphasic Calcium Phosphate Scaffold with High Permeability/Porosity Ratio
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Macroporous biphasic calcium phosphate (BCP) with channel-shaped pores was produced by a novel dual-phase mixing method. The processing route includes mixing water-based BCP slurry and polymethylmethacrylate resin; shaping in a mold; and polymerization, drying, pyrolyzing, and sintering. After comparison with two other commercial macroporous BCP materials, which were produced along different routes, it was found that conventional parameters such as porosity and pore size cannot describe a macroporous structure precisely enough for the application as tissue-engineering scaffold. Instead, permeability can be seen as an intrinsic and quantitative parameter to describe the macroporous structure of various scaffolds, because it is independent of sample size and fluid used in the test. Another parameter, the permeability/porosity ratio, provides an indication of the percolative efficiency per unit porous volume of a scaffold. Structural characterizations and permeability studies of other macroporous scaffold materials were also performed, and it was found that permeability could reflect a combination of five important parameters for scaffold: (1) porosity, (2) pore size and distribution, (3) interconnectivity, (4) fenestration size and distribution, and (5) orientation of pores. Finally, the implications of relating permeability with biological performances are also discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cellular solids structure and properties
Gibson, L. J., Ashby, M. F., et al. (1997) · Cited by 9,172
Tissue-engineered bone regeneration
Petite, H., Viateau, V., Bensaïd, W., Meunier, A., de Pollak, C., Bourguignon, M., Oudina, K., Sedel, L., & Guillemin, G. (2000) · Nature Biotechnology · doi:10.1038/79449 · Cited by 1,475
Potential of ceramic materials as permanently implantable skeletal prostheses
Hulbert, S. F., Young, F. A., Mathews, R. S., Klawitter, J. J., Talbert, C. D., & Stelling, F. H. (1970) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820040309 · Cited by 1,019
Kon, E., Muraglia, A., Corsi, A., Bianco, P., Marcacci, M., Martin, I., Boyde, A., Ruspantini, I., Chistolini, P., Rocca, M., et al. (2000) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(20000305)49:3<328::aid-jbm5>3.0.co;2-q · Cited by 721
Gauthier, O., Bouler, J.-M., Aguado, E., Pilet, P., & Daculsi, G. (1998) · Biomaterials · doi:10.1016/s0142-9612(97)00180-4 · Cited by 614
Radin, S. R., & Ducheyne, P. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820270106 · Cited by 521
Ducheyne, P., Radin, S., & King, L. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820270105 · Cited by 467
Kadiyala, S., Jaiswal, N., & Bruder, S. P. (1997) · Tissue Engineering · doi:10.1089/ten.1997.3.173 · Cited by 255
Dependence of Intertrabecular Permeability on Flow Direction and Anatomic Site
Nauman, E. A., Fong, K. E., & Keaveny, T. M. (1999) · Annals of Biomedical Engineering · doi:10.1114/1.195 · Cited by 249
An image-based approach for designing and manufacturing craniofacial scaffolds
Hollister, S. J., Levy, R. A., Chu, T.-M., Halloran, J. W., & Feinberg, S. E. (2000) · International Journal of Oral and Maxillofacial Surgery · doi:10.1034/j.1399-0020.2000.290115.x · Cited by 219
Cited by
Bioceramics of calcium orthophosphates
Dorozhkin, S. V. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.11.050 · Cited by 1,338
Bioactive Glass and Glass-Ceramic Scaffolds for Bone Tissue Engineering
Gerhardt, L.-C., & Boccaccini, A. R. (2010) · Materials · doi:10.3390/ma3073867 · Cited by 1,179
Scaffolds for tissue fabrication
Ma, P. X. (2004) · Materials Today · doi:10.1016/s1369-7021(04)00233-0 · Cited by 1,077
Osteoinductive ceramics as a synthetic alternative to autologous bone grafting
Yuan, H., Fernandes, H., Habibovic, P., de Boer, J., Barradas, A. M. C., de Ruiter, A., Walsh, W. R., van Blitterswijk, C. A., & de Bruijn, J. D. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1003600107 · Cited by 746
“HA ceramics were prepared from HA powder (Merck) using the dual-phase mixing method and sintered at 1250 °C for 8 h according to a previously described method (35).”
MethodKarande, T. S., Ong, J. L., & Agrawal, C. M. (2004) · Annals of Biomedical Engineering · doi:10.1007/s10439-004-7825-2 · Cited by 457
Bone ingrowth in porous titanium implants produced by 3D fiber deposition
Li, J. P., Habibovic, P., van den Doel, M., Wilson, C. E., de Wijn, J. R., van Blitterswijk, C. A., & de Groot, K. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.02.020 · Cited by 393
Self-citationO'Brien, F. J., Harley, B. A., Waller, M. A., Yannas, I. V., Gibson, L. J., & Prendergast, P. J. (2006) · Technology and Health Care · doi:10.3233/thc-2007-15102 · Cited by 366
Bioceramic Bone Graft Substitutes: Influence of Porosity and Chemistry
Hing, K. A. (2005) · International Journal of Applied Ceramic Technology · doi:10.1111/j.1744-7402.2005.02020.x · Cited by 365
Biphasic, triphasic and multiphasic calcium orthophosphates
Dorozhkin, S. V. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.09.003 · Cited by 357
Biodegradable magnesium alloys as temporary orthopaedic implants: a review
Kamrani, S., & Fleck, C. (2019) · BioMetals · doi:10.1007/s10534-019-00170-y · Cited by 325
Calcium Orthophosphate-Based Bioceramics
Dorozhkin, S. (2013) · Materials · doi:10.3390/ma6093840 · Cited by 295
In vivo behavior of calcium phosphate scaffolds with four different pore sizes
von Doernberg, M.-C., von Rechenberg, B., Bohner, M., Grünenfelder, S., van Lenthe, G. H., Müller, R., Gasser, B., Mathys, R., Baroud, G., & Auer, J. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.05.051 · Cited by 285
Calcium Orthophosphates as Bioceramics: State of the Art
Dorozhkin, S. V. (2010) · Journal of Functional Biomaterials · doi:10.3390/jfb1010022 · Cited by 278
The effect of PEGT/PBT scaffold architecture on the composition of tissue engineered cartilage
Malda, J., Woodfield, T. B. F., van der Vloodt, F., Wilson, C., Martens, D. E., Tramper, J., van Blitterswijk, C. A., & Riesle, J. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.02.046 · Cited by 234
Macroporous Elastomeric Scaffolds with Extensive Micropores for Soft Tissue Engineering
Gao, J., Crapo, P. M., & Wang, Y. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.917 · Cited by 211
“Ideally, tissue-engineered scaffolds should meet three criteria: 1) high porosity with adequate pore intercon-nectivity; 17,18 2) surface-mediated cell adhesion and proliferation, facilitating cell-cell contact and cell migration; 19 and 3) mechanical properties matching those of the tissue at the…”
Al‐Munajjed, A. A., Plunkett, N. A., Gleeson, J. P., Weber, T., Jungreuthmayer, C., Levingstone, T., Hammer, J., & O'Brien, F. J. (2009) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31320 · Cited by 198
Optimization of scaffold design for bone tissue engineering: A computational and experimental study
Dias, M. R., Guedes, J. M., Flanagan, C. L., Hollister, S. J., & Fernandes, P. R. (2014) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2014.02.010 · Cited by 171
Chondroitin Sulfate-Based Biomineralizing Surface Hydrogels for Bone Tissue Engineering
Kim, H. D., Lee, E. A., An, Y.-H., Kim, S. L., Lee, S. S., Yu, S. J., Jang, H. L., Nam, K. T., Im, S. G., & Hwang, N. S. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b04114 · Cited by 161
Multiphasic calcium orthophosphate (CaPO 4 ) bioceramics and their biomedical applications
Dorozhkin, S. V. (2016) · Ceramics International · doi:10.1016/j.ceramint.2016.01.062 · Cited by 159
Metadata
- Authors
- Li, S., de Wijn, J. R., Li, J., Layrolle, P., & de Groot, K.
- Venue
- Tissue Engineering
- Publisher
- SAGE Publications
- Published
- 2003-06
- Volume
- 9
- Issue
- 3
- Pages
- 535-548
- ISSN
- 1076-3279 (ISSN-L)
- 1557-8690
- OpenAlex
- W2008827598
- Cited by
- 212
- References
- 19
- FWCI
- 5.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.