The DOI matches its Crossref record.
Mechanical Strain-Stimulated Remodeling of Tissue-Engineered Blood Vessel Constructs
Abstract
Progress in tissue-engineering research has renewed optimism about the possibility of constructing a physiologically functional blood vessel substitute in the laboratory. To this end, we have explored the use of defined mechanical stimulation to further the development of vascular tissue analogs. We now report our findings on smooth muscle cell and fibroblast-seeded collagen constructs exposed to 10% cyclic strain for 4 or 8 days. Our results demonstrate that 4-day strained constructs exhibit an enhancement of mechanical properties, likely through the remodeling actions of matrix metalloproteinase 2 (MMP-2). Strain-stimulated expression of MMP-2 is accompanied by alterations in elastin and collagen gene expression. In the context of tissue engineering a blood vessel construct, we report that strain-stimulated regulation of MMP-2 activity could have a favorable impact on the structural development of the constructs whereas overexpression of MMP-2 during prolonged exposure to strain (8 days) could have adverse consequences on the structural integrity of the tissue analogs. Taken together, these results illustrate the importance of mechanical stimulus as a major regulatory component of tissue-engineered blood vessel remodeling.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Tissue-Engineered Vascular Graft—Past, Present, and Future
Pashneh-Tala, S., MacNeil, S., & Claeyssens, F. (2016) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2015.0100 · Cited by 798
Small-diameter vascular tissue engineering
Seifu, D. G., Purnama, A., Mequanint, K., & Mantovani, D. (2013) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2013.77 · Cited by 501
Beamish, J. A., He, P., Kottke-Marchant, K., & Marchant, R. E. (2010) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2009.0630 · Cited by 383
Biofabrication: a 21st century manufacturing paradigm
Mironov, V, Trusk, T., Kasyanov, V, Little, S., Swaja, R., & Markwald, R. (2009) · Biofabrication · doi:10.1088/1758-5082/1/2/022001 · Cited by 362
Elastin biosynthesis: The missing link in tissue-engineered blood vessels
PATEL, A., FINE, B., SANDIG, M., & MEQUANINT, K. (2006) · Cardiovascular Research · doi:10.1016/j.cardiores.2006.02.021 · Cited by 328
Metadata
- Authors
- Seliktar, D., Nerem, R. M., & Galis, Z. S.
- Venue
- Tissue Engineering
- Publisher
- SAGE Publications
- Published
- 2003-08
- Volume
- 9
- Issue
- 4
- Pages
- 657-666
- ISSN
- 1076-3279 (ISSN-L)
- 1557-8690
- OpenAlex
- W1970877757
- Cited by
- 179
- References
- 0
- FWCI
- 10.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mechanical Strain-Stimulated Remodeling of Tissue-Engineered Blood Vessel Constructs. https://app.cochat.ai/papers/10.1089/107632703768247359
- The paper
- Seliktar, D., Nerem, R. M., & Galis, Z. S. (2003). Mechanical Strain-Stimulated Remodeling of Tissue-Engineered Blood Vessel Constructs. Tissue Engineering. https://doi.org/10.1089/107632703768247359
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.