Mechanical Strain-Stimulated Remodeling of Tissue-Engineered Blood Vessel Constructs
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
Progress in tissue-engineering research has renewed optimism about the possibility of constructing a physiologically functional blood vessel substitute in the laboratory. To this end, we have explored the use of defined mechanical stimulation to further the development of vascular tissue analogs. We now report our findings on smooth muscle cell and fibroblast-seeded collagen constructs exposed to 10% cyclic strain for 4 or 8 days. Our results demonstrate that 4-day strained constructs exhibit an enhancement of mechanical properties, likely through the remodeling actions of matrix metalloproteinase 2 (MMP-2). Strain-stimulated expression of MMP-2 is accompanied by alterations in elastin and collagen gene expression. In the context of tissue engineering a blood vessel construct, we report that strain-stimulated regulation of MMP-2 activity could have a favorable impact on the structural development of the constructs whereas overexpression of MMP-2 during prolonged exposure to strain (8 days) could have adverse consequences on the structural integrity of the tissue analogs. Taken together, these results illustrate the importance of mechanical stimulus as a major regulatory component of tissue-engineered blood vessel remodeling.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tissue Engineering--Current Challenges and Expanding Opportunities
Griffith, L. G., & Naughton, G. (2002) · Science · doi:10.1126/science.1069210 · Cited by 2,343 · cited 1×
“The role of MMP-2, therefore, appears to be 2-fold: (1) MMP-2 facilitates a remodeling response associated with cyclic strain stimulation; and (2) MMP-2 accumulation contributes to the overall deterioration in mechanical integrity of the constructs when presented in large amounts.”
Functional Arteries Grown in Vitro
Niklason, L. E., Gao, J., Abbott, W. M., Hirschi, K. K., Houser, S., Marini, R., & Langer, R. (1999) · Science · doi:10.1126/science.284.5413.489 · Cited by 1,766
A completely biological tissue-engineered human blood vessel
L'heureux, N., Pâquet, S., Labbé, R., Germain, L., & Auger, F. A. (1998) · The FASEB Journal · doi:10.1096/fasebj.12.1.47 · Cited by 1,402
Matrix Metalloproteinase-2 Is an Interstitial Collagenase
Aimes, R. T., & Quigley, J. P. (1995) · Journal of Biological Chemistry · doi:10.1074/jbc.270.11.5872 · Cited by 944
Galis, Z. S., Muszynski, M., Sukhova, G. K., Simon-Morrissey, E., Unemori, E. N., Lark, M. W., Amento, E., & Libby, P. (1994) · Circulation Research · doi:10.1161/01.res.75.1.181 · Cited by 646
Self-citationFluid Mechanics of Vascular Systems, Diseases, and Thrombosis
Wootton, D. M., & Ku, D. N. (1999) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.1.1.299 · Cited by 559
Dynamic Mechanical Conditioning of Collagen-Gel Blood Vessel Constructs Induces Remodeling In Vitro
Seliktar, D., Black, R. A., Vito, R. P., & Nerem, R. M. (2000) · Annals of Biomedical Engineering · doi:10.1114/1.275 · Cited by 555
Self-citationHuman 92- and 72-kilodalton type IV collagenases are elastases.
Senior, R. M., Griffin, G. L., Fliszar, C. J., Shapiro, S. D., Goldberg, G. I., & Welgus, H. G. (1991) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(20)89530-1 · Cited by 545
Cyclic mechanical strain regulates the development of engineered smooth muscle tissue
Kim, B.-S., Nikolovski, J., Bonadio, J., & Mooney, D. J. (1999) · Nature Biotechnology · doi:10.1038/13671 · Cited by 491
Nerem, R. M., & Seliktar, D. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.225 · Cited by 466
Self-citation
Cited by
The Tissue-Engineered Vascular Graft—Past, Present, and Future
Pashneh-Tala, S., MacNeil, S., & Claeyssens, F. (2016) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2015.0100 · Cited by 798
Small-diameter vascular tissue engineering
Seifu, D. G., Purnama, A., Mequanint, K., & Mantovani, D. (2013) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2013.77 · Cited by 501
Beamish, J. A., He, P., Kottke-Marchant, K., & Marchant, R. E. (2010) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2009.0630 · Cited by 383
Biofabrication: a 21st century manufacturing paradigm
Mironov, V, Trusk, T., Kasyanov, V, Little, S., Swaja, R., & Markwald, R. (2009) · Biofabrication · doi:10.1088/1758-5082/1/2/022001 · Cited by 362
Elastin biosynthesis: The missing link in tissue-engineered blood vessels
PATEL, A., FINE, B., SANDIG, M., & MEQUANINT, K. (2006) · Cardiovascular Research · doi:10.1016/j.cardiores.2006.02.021 · Cited by 328
Collagen—emerging collagen based therapies hit the patient
Abou Neel, E. A., Bozec, L., Knowles, J. C., Syed, O., Mudera, V., Day, R., & Hyun, J. K. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.08.010 · Cited by 296
“erties have been suggested to be due to gel compaction, and fibril orientation that the cells produce [136–140].”
BackgroundMechanical, biochemical, and extracellular matrix effects on vascular smooth muscle cell phenotype
Stegemann, J. P., Hong, H., & Nerem, R. M. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01114.2004 · Cited by 291
Self-citationA bilayered elastomeric scaffold for tissue engineering of small diameter vascular grafts
Soletti, L., Hong, Y., Guan, J., Stankus, J. J., El-Kurdi, M. S., Wagner, W. R., & Vorp, D. A. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.06.026 · Cited by 289
Engineering of fibrin-based functional and implantable small-diameter blood vessels
Swartz, D. D., Russell, J. A., & Andreadis, S. T. (2005) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00479.2004 · Cited by 277
Syedain, Z. H., Meier, L. A., Bjork, J. W., Lee, A., & Tranquillo, R. T. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2010.09.019 · Cited by 254
Bioengineered human blood vessels
Niklason, L. E., & Lawson, J. H. (2020) · Science · doi:10.1126/science.aaw8682 · Cited by 254
Chen, Q., Zhu, C., & Thouas, G. A. (2012) · Progress in Biomaterials · doi:10.1186/2194-0517-1-2 · Cited by 240
“Over the past 10 years, there have been an increasing number of research groups working on the development of biodegradable elastomeric biomaterials for bone tissue engineering applications (Li et al 2012; Kim and Mooney 2000; Niklason et al. 1999; Seliktar et al. 2003; Stegemann and Nerem 2003; Waldman et al. 2004; W…”
BackgroundTissue engineering of blood vessel
Zhang, W. J., Liu, W., Cui, L., & Cao, Y. (2007) · Journal of Cellular and Molecular Medicine · doi:10.1111/j.1582-4934.2007.00099.x · Cited by 217
“Moore et al. demonstrated that cyclic strain could reduce the cell death [101], while Seliktar et al. found that cyclic strain could increase the matrix re-modelling by overexpression matrix re-modelling enzymes, such as matrix metalloproteinase 2 (MMP-2) [102, 103].”
BackgroundReview: Advances in Vascular Tissue Engineering Using Protein-Based Biomaterials
Stegemann, J. P., Kaszuba, S. N., & Rowe, S. L. (2007) · Tissue Engineering · doi:10.1089/ten.2007.0196 · Cited by 205
“32 In general, bioreactor culture has been shown to increase the mechanical properties of protein hydrogel constructs, and newer bioreactor systems have begun to combine circumferential tensile strain with perfusion and shear, 33,34 longitudinal strain, 35 and even electrical stimulation.”
Liu, Q., Jiang, L., Shi, R., & Zhang, L. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2011.11.001 · Cited by 203
Abou Neel, E. A., Cheema, U., Knowles, J. C., Brown, R. A., & Nazhat, S. N. (2006) · Soft Matter · doi:10.1039/b609784g · Cited by 199
Injectable Biopolymers Enhance Angiogenesis after Myocardial Infarction
Huang, N. F., Yu, J., Sievers, R., Li, S., & Lee, R. J. (2005) · Tissue Engineering · doi:10.1089/ten.2005.11.1860 · Cited by 196
Stress-driven collagen fiber remodeling in arterial walls
Hariton, I., deBotton, G., Gasser, T. C., & Holzapfel, G. A. (2007) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-006-0049-7 · Cited by 191
“Strain-induced fiber alignment in man-made tissues is also discussed by Barocas and Tranquillo (1997) and Seliktar et al. (2003) .”
BackgroundCurable, biodegradable elastomers: emerging biomaterials for drug delivery and tissue engineering
Amsden, B. (2007) · Soft Matter · doi:10.1039/b707472g · Cited by 186
Syedain, Z. H., Weinberg, J. S., & Tranquillo, R. T. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0711217105 · Cited by 179
Biomimetic 3D tissue models for advanced high-throughput drug screening
Nam, K.-H., Smith, A. S. T., Lone, S., Kwon, S., & Kim, D.-H. (2015) · SLAS Technology · doi:10.1177/2211068214557813 · Cited by 171
Biocompatibility of Acellular Human Pericardium
Mirsadraee, S., Wilcox, H. E., Watterson, K. G., Kearney, J. N., Hunt, J., Fisher, J., & Ingham, E. (2007) · Journal of Surgical Research · doi:10.1016/j.jss.2007.01.026 · Cited by 104
Stem cell sources for vascular tissue engineering and regeneration
Bajpai, V. K., & Andreadis, S. T. (2012) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2011.0264 · Cited by 95
Metadata
- Authors
- Seliktar, D., Nerem, R. M., & Galis, Z. S.
- Venue
- Tissue Engineering
- Publisher
- SAGE Publications
- Published
- 2003-08
- Volume
- 9
- Issue
- 4
- Pages
- 657-666
- ISSN
- 1076-3279 (ISSN-L)
- 1557-8690
- OpenAlex
- W1970877757
- Cited by
- 179
- References
- 18
- FWCI
- 10.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.