The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Elastin biosynthesis: The missing link in tissue-engineered blood vessels
Abstract
Nearly 20 years have passed since Weinberg and Bell attempted to make the first tissue-engineered blood vessels. Following this early attempt, vascular tissue engineering has emerged as one of the most promising approaches to fabricate orderly and mechanically competent vascular substitutes. In elastic and muscular arteries, elastin is a critical structural and regulatory matrix protein and plays an important and dominant role by conferring elasticity to the vessel wall. Elastin also regulates vascular smooth muscle cells activity and phenotype. Despite the great promise that tissue-engineered blood vessels have to offer, little research in the last two decades has addressed the importance of elastin incorporation into these vessels. Although cardiovascular tissue engineering has been reviewed in the past, very little attention has been given to elastin. Thus, this review focuses on the recent advances made towards elastogenesis and the challenges we face in the quest for appropriate functional vascular substitutes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Creation of long-lasting blood vessels
Koike, N., Fukumura, D., Gralla, O., Au, P., Schechner, J. S., & Jain, R. K. (2004) · Nature · doi:10.1038/428138a · Cited by 701
Fluctuations of intracellular iron modulate elastin production
Bunda, S., Kaviani, N., & Hinek, A. (2005) · Journal of Biological Chemistry · doi:10.1074/jbc.m409897200 · Cited by 40
Cited by
Elastomeric biomaterials for tissue engineering
Chen, Q., Liang, S., & Thouas, G. A. (2013) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2012.05.003 · Cited by 564
Scaffold: A Novel Carrier for Cell and Drug Delivery
Garg, T., Singh, O., Arora, S., & Murthy, R. S. R. (2012) · Critical Reviews in Therapeutic Drug Carrier Systems · doi:10.1615/critrevtherdrugcarriersyst.v29.i1.10 · Cited by 549
Askari, M., Afzali Naniz, M., Kouhi, M., Saberi, A., Zolfagharian, A., & Bodaghi, M. (2021) · Biomaterials Science · doi:10.1039/d0bm00973c · Cited by 369
Elastin, arterial mechanics, and cardiovascular disease
Cocciolone, A. J., Hawes, J. Z., Staiculescu, M. C., Johnson, E. O., Murshed, M., & Wagenseil, J. E. (2018) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00087.2018 · Cited by 341
Yeo, G. C., Keeley, F. W., & Weiss, A. S. (2011) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2010.10.003 · Cited by 255
Metadata
- Authors
- PATEL, A., FINE, B., SANDIG, M., & MEQUANINT, K.
- Venue
- Cardiovascular Research
- Publisher
- Oxford University Press (OUP)
- Published
- 2006-07-01
- Volume
- 71
- Issue
- 1
- Pages
- 40-49
- ISSN
- 0008-6363 (ISSN-L)
- OpenAlex
- W2130744701
- Cited by
- 328
- References
- 2
- FWCI
- 14.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Elastin biosynthesis: The missing link in tissue-engineered blood vessels. https://app.cochat.ai/papers/10.1016/j.cardiores.2006.02.021
- The paper
- PATEL, A., FINE, B., SANDIG, M., & MEQUANINT, K. (2006). Elastin biosynthesis: The missing link in tissue-engineered blood vessels. Cardiovascular Research. https://doi.org/10.1016/j.cardiores.2006.02.021
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.