The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
In Vitro and in Vivo Degradation of Mineralized Collagen-Based Composite Scaffold: Nanohydroxyapatite/Collagen/Poly(L-lactide)
Abstract
The objective of this article was to investigate the in vitro and in vivo biodegradation of a novel biomimetic bone scaffold composite, nanohydroxyapatite/collagen/poly(L-lactide), that could be used for bone tissue engineering. For evaluation of in vitro degradation specimens were immersed into 1% trypsin/phosphate-buffered saline solution at 37 degrees C. In vivo evaluation involved the implantation of samples into the posterolateral lumbar spine of rabbits, and the retrieved specimens were analyzed by Fourier transform-infrared spectroscopy. The results demonstrated that weight loss increased continuously in vitro with a reduction in mass of 19.6% after 4 weeks. During the experimental period in vitro, the relative rate of reduction of the three components in this material was shown to differ greatly: collagen decreased the fastest, from 40% by weight to 20% in the composite; hydroxyapatite content increased from 45 to 60%; and PLA changed little. The pore structure was maintained throughout the whole experimental period in vitro; however, the thickness of the walls of the pores decreased and the surface of the walls increased in roughness. In vivo, the ratio of collagen to hydroxyapatite appeared to be slightly higher near the transverse process than in the central part of the intertransverse process. This finding may have been due to new bone matrix formation extending from the transverse to the intertransverse process.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In the invivo condition, there were no appropriate quantitative data regarding the degradation rate”
From Nano-hydroxyapatite/collagen composite as scaffold material for bone regeneration. (2023) · cites this paper as [87]
In the citing paper
“Liao et al [87] studied the in-vitro (1% trypsin/phosphatebuffered saline solution) and in-vivo (implanted in the posterolateral lumbar spine of rabbits) biodegradation of nano-HA, collagen, and poly(L-lactide) (PLLA) scaffold fabricated through freeze drying process.”
From Nano-hydroxyapatite/collagen composite as scaffold material for bone regeneration. (2023) · cites this paper as [87]
In the citing paper
“approximate measurements showed that the in-vivo degradation was faster than in-vitro.”
From Nano-hydroxyapatite/collagen composite as scaffold material for bone regeneration. (2023) · cites this paper as [87]
In the citing paper
“However, after 28 d the pore wall thickness declined to 2 µm substantiating the degradation process.”
From Nano-hydroxyapatite/collagen composite as scaffold material for bone regeneration. (2023) · cites this paper as [87]
In the citing paper
“Even though the pore thickness has decreased, the pores along with pore walls were still visible.”
From Nano-hydroxyapatite/collagen composite as scaffold material for bone regeneration. (2023) · cites this paper as [87]
In the citing paper
“After 4 weeks, there was a 19.6% weight loss due to the degradation of the scaffold material.”
From Nano-hydroxyapatite/collagen composite as scaffold material for bone regeneration. (2023) · cites this paper as [87]
In the citing paper
“From the SEM images of the scaffold after 10 d of in-vitro treatment, the porous structures were found to be intact with a wall thickness of about 10 µm.”
From Nano-hydroxyapatite/collagen composite as scaffold material for bone regeneration. (2023) · cites this paper as [87]
In the citing paper
“Due to the presence of collagenase inside the body, collagen degrades rapidly and it is difficult to monitor the degradation behavior of collagen in vivo [87,122].”
From Nano-hydroxyapatite/collagen composite as scaffold material for bone regeneration. (2023) · cites this paper as [87]
In the citing paper
“Due to the presence of collagenase inside the body, collagen degrades rapidly and it is difficult to monitor the degradation behavior of collagen in vivo [87,122].”
From Nano-hydroxyapatite/collagen composite as scaffold material for bone regeneration. (2023) · cites this paper as [87]
Citations
Cites
Langer, R., & Vacanti, J. P. (1993) · Science · doi:10.1126/science.8493529 · Cited by 9,893
Bone formation by three-dimensional stromal osteoblast culture in biodegradable polymer scaffolds
Ishaug, S. L., Crane, G. M., Miller, M. J., Yasko, A. W., Yaszemski, M. J., & Mikos, A. G. (1997) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199707)36:1 · Cited by 832
Host response to tissue engineered devices
Babensee, J. E., Anderson, J. M., McIntire, L. V., & Mikos, A. G. (1998) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(98)00023-4 · Cited by 585
Hierarchically biomimetic bone scaffold materials: nano‐HA/collagen/PLA composite
Liao, S. S., Cui, F. Z., Zhang, W., & Feng, Q. L. (2004) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.20035 · Cited by 487 · cited 3×
“6,8,9 PLA of molecular weight 40,000–60,000 was dissolved in dioxane to a final concentration of 8% (m/v), and then the solution was gently stirred at room temperature for 4 to 6 h. After-ward, nHAC powder was added.”
Self-citationTissue Engineering: Current State and Prospects
Stock, U. A., & Vacanti, J. P. (2001) · Annual Review of Medicine · doi:10.1146/annurev.med.52.1.443 · Cited by 487
Wetting of poly(l-lactic acid) and poly(dl-lactic-co-glycolic acid) foams for tissue culture
Mikos, A. G., Lyman, M. D., Freed, L. E., & Langer, R. (1994) · Biomaterials · doi:10.1016/0142-9612(94)90197-x · Cited by 409
Mechanical Properties and Composition of Cortical Bone
Carter, D. R., & Spengler, D. M. (1978) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-197809000-00041 · Cited by 407
An Experimental Lumbar Intertransverse Process Spinal Fusion Model
Boden, S. D., Schimandle, J. H., & Hutton, W. (1995) · Spine · doi:10.1097/00007632-199502001-00003 · Cited by 360
Development of biodegradable porous scaffolds for tissue engineering
Chen, G., Ushida, T., & Tateishi, T. (2001) · Materials Science and Engineering C · doi:10.1016/s0928-4931(01)00338-1 · Cited by 238
Biocompatibility of anionic collagen matrix as scaffold for bone healing
Rocha, L. B., Góissis, G., & Rossi, M. A. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00126-0 · Cited by 186
Microspheres of hydroxyapatite/reconstituted collagen as supports for osteoblast cell growth
Hsu, F. Y., Chueh, S., & Wang, Y. J. (1999) · Biomaterials · doi:10.1016/s0142-9612(99)00095-2 · Cited by 166
Camacho, N. P., Rinnerthaler, S., Paschalis, E. P., Mendelsohn, R., Boskey, A. L., & Fratzl, P. (1999) · Bone · doi:10.1016/s8756-3282(99)00165-9 · Cited by 154
Synthesis of nanophase hydroxyapatite/collagen composite
Wang, R. Z., Cui, F. Z., Lu, H. B., Wen, H. B., L., C., & Li, H. D. (1995) · Journal of Materials Science Letters · doi:10.1007/bf00665911 · Cited by 154
Self-citationA study of HAp/PLLA composite as a substitute for bone powder, using FT-IR spectroscopy
Ignjatović, N. L., Savić, V., Najman, S. J., Plavsic, M. B., & Uskokovic, D. P. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00215-5 · Cited by 139
Versatility of biodegradable biopolymers: degradability and an in vivo application
Hasırcı, V., Lewandrowski, K., Gresser, J. D., Wise, D. L., & Trantolo, D. J. (2001) · Journal of Biotechnology · doi:10.1016/s0168-1656(00)00409-0 · Cited by 134
Liao, S., Cui, F., & Zhu, Y. (2004) · Journal of Bioactive and Compatible Polymers · doi:10.1177/0883911504042643 · Cited by 125
Self-citationUse of a Collagen-Hydroxyapatite Matrix in Spinal Fusion
Tay, B. K.-B., Le, A. X., Heilman, M., Lotz, J. C., & Bradford, D. S. (1998) · Spine · doi:10.1097/00007632-199811010-00005 · Cited by 114
Jones, S. J., & BOYDE, A. (1977) · Cell and Tissue Research · doi:10.1007/bf00223067 · Cited by 112
Aframian, D. J., Cukierman, E., Nikolovski, J., Mooney, D. J., Yamada, K. M., & Baum, B. J. (2000) · Tissue Engineering · doi:10.1089/10763270050044380 · Cited by 111
Spiro, R. C., Thompson, A. Y., & Poser, J. W. (2001) · The Anatomical Record · doi:10.1002/ar.1119 · Cited by 54
Degradation-resistant character of synthetic hydroxyapatite blocks filled in bone defects
Yamaguchi, K., Hirano, T., Yoshida, G., & Iwasaki, K. (1995) · Biomaterials · doi:10.1016/0142-9612(95)94905-z · Cited by 51
Taddei, P., Monti, P., & Simoni, R. (2002) · Journal of Materials Science Materials in Medicine · doi:10.1023/a:1014742003146 · Cited by 42
Solubilization of hydroxyapatite crystals by murine bone cells, macrophages and fibroblasts
Kwong, C. H., Burns, W. B., & Cheung, H. S. (1989) · Biomaterials · doi:10.1016/0142-9612(89)90110-5 · Cited by 41
Resorbable Device for Fracture Fixation: In Vivo Degradation and Mechanical Behaviour
Fini, M., Giannini, S., Giardino, R., Giavaresi, G., Grimaldi, M., Aldini, N. N., Orienti, L., & Rocca, M. (1995) · The International Journal of Artificial Organs · doi:10.1177/039139889501801205 · Cited by 32
Applications of infrared spectroscopy to biology and medicine
Mantsch, H. H., & McElhaney, R. N. (1990) · Journal of Molecular Structure · doi:10.1016/0022-2860(90)80374-s · Cited by 30
Young, T., Lin, D., & Chen, L.-Y. (2000) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(20000615)50:4 · Cited by 27
Self-citationTaddei, P., Monti, P., & Simoni, R. (2002) · Journal of Materials Science Materials in Medicine · doi:10.1023/a:1013686502867 · Cited by 20
Research works printed but not linked: 2
- Hsu F.Y., 1931, Biomaterials, 20, 1999
- Carter D.R., 1978, Clin. Orthop., 135, 193
Cited by
Sorted by citations
Hutmacher, D. W., Schantz, J. T., Lam, C. X. F., Tan, K. C., & Lim, T. C. (2007) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.24 · Cited by 1,007
Self-assembly of mineralized collagen composites
Cui, F., Li, Y., & Ge, J. (2007) · Materials Science and Engineering R Reports · doi:10.1016/j.mser.2007.04.001 · Cited by 338
Self-citationCalcium orthophosphate-based biocomposites and hybrid biomaterials
Dorozhkin, S. V. (2009) · Journal of Materials Science · doi:10.1007/s10853-008-3124-x · Cited by 303
Niu, X., Feng, Q., Wang, M., Guo, X., & Zheng, Q. (2009) · Journal of Controlled Release · doi:10.1016/j.jconrel.2008.11.020 · Cited by 296
Current strategies in multiphasic scaffold design for osteochondral tissue engineering: A review
Yousefi, A., Hoque, M. E., Prasad, R. G. S. V., & Uth, N. (2014) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.35356 · Cited by 207
Metadata
- Authors
- Liao, S. S., & Cui, F. Z.
- Affiliations
- Tsinghua University (CN)
- ORCID
- Venue
- Tissue Engineering
- Publisher
- SAGE Publications
- Published
- 2004-01
- Volume
- 10
- Issue
- 1-2
- Pages
- 73-80
- ISSN
- 1076-3279 (ISSN-L)
- 1557-8690
- OpenAlex
- W1996507095
- Cited by
- 142
- References
- 27
- Citations by year
- 2026: 2 · 2025: 1 · 2024: 4 · 2023: 2 · 2022: 2 · 2021: 6 · 2020: 8 · 2019: 2 · 2018: 2 · 2017: 6 · 2016: 13 · 2015: 15 · 2014: 7 · 2013: 4 · 2012: 10
- FWCI
- 6.46
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Tissue Engineering (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
- Physical Sciences › Materials Science › Biomaterials › Collagen: Extraction and Characterization
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Keywords
- biodegradation, hydroxyapatite nanoparticles, collagen, poly(L-lactic acid), bone scaffolds, bone tissue engineering, trypsin degradation, in vivo implantation, lumbar spine, new bone formation, pore structure, weight loss
- MeSH terms
- Animals, Collagen, Hydrogen-Ion Concentration, Lumbar Vertebrae, Polyesters, Rabbits, Temperature, Time Factors, Spectroscopy, Fourier Transform Infrared, Durapatite, Bone Substitutes, Prostheses and Implants, In Vitro Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review