The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Comparison of Glucose Concentration in Interstitial Fluid, and Capillary and Venous Blood During Rapid Changes in Blood Glucose Levels
Abstract
The relationship between glucose concentrations in interstitial fluid (ISF) and blood has generated great interest due to its importance in minimally invasive and noninvasive techniques for measuring blood glucose. The relationship between glucose levels in dermal ISF, and capillary and venous blood was studied with the dermal ISF samples obtained using the suction blister technique. The study was conducted with intensely managed diabetics whose blood glucose levels were manipulated so as to induce rapid changes in blood glucose levels. Glucose levels in the three compartments exhibited high correlations both when individual subjects were considered separately and when data from all subjects were combined. No significant time lag during glucose excursions was observed among the ISF, and capillary and venous glucose levels.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This function, and the associated ISF composition, lead to reliable correlations between the blood and ISF concentrations of many analytes, including electrolytes (e.g., sodium, phosphate, magnesium, potassium or calcium), metabolites (e.g., glucose, alcohol, lactate or cortisol) and proteins65-69.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [65]
Citations
Cites
A microdialysis method allowing characterization of intercellular water space in humans
Lönnroth, P., Jansson, P., & Smith, U. (1987) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1987.253.2.e228 · Cited by 634
Rebrin, K., Steil, G. M., van Antwerp, W. P., & Mastrototaro, J. J. (1999) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1999.277.3.e561 · Cited by 367
Noninvasive Prediction of Glucose by Near-Infrared Diffuse Reflectance Spectroscopy
Malin, S. F., Ruchti, T. L., Blank, T. B., Thennadil, S. N., & Monfre, S. L. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.9.1651 · Cited by 233
Self-citationCan Interstitial Glucose Assessment Replace Blood Glucose Measurements?
Rebrin, K., & Steil, G. M. (2000) · Diabetes Technology & Therapeutics · doi:10.1089/15209150050194332 · Cited by 227
Implications of the Diabetes Control and Complications Trial
American Diabetes Association (2003) · Diabetes Care · doi:10.2337/diacare.26.2007.s25 · Cited by 182
The Diabetes Control and Complications Trial -- Implications for Policy and Practice
Lasker, R. D. (1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291410 · Cited by 177
Microdialysis of subcutaneous adipose tissue in vivo for continuous glucose monitoring in man
Bolinder, J., Hagström, E., Ungerstedt, U., & Arner, P. (1989) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365518909089123 · Cited by 130
Glucose measurement in patients with diabetes mellitus with dermal interstitial fluid
Bantle, J. P., & Thomas, W. (1997) · Journal of Laboratory and Clinical Medicine · doi:10.1016/s0022-2143(97)90044-5 · Cited by 128
Characterization by microdialysis of intracellular glucose level in subcutaneous tissue in humans
Jansson, P., Fowelin, J., Smith, U., & Lönnroth, P. (1988) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1988.255.2.e218 · Cited by 119
Biosensors in the body : continuous in vivo monitoring
Fraser, D. M. (1997) · Wiley eBooks · Cited by 85
Direct access to interstitial fluid in adipose tissue in humans by use of open-flow microperfusion
Schaupp, L., Ellmerer, M., Brunner, G. A., Wutte, A., Sendlhofer, G., Trajanoski, Z., Skrabal, F., Pieber, T. R., & Wach, P. (1999) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1999.276.2.e401 · Cited by 75
Petersen, L., Jk, K., & Bülow, J. (1992) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12616676 · Cited by 74
Microdialysis of subcutaneous adipose tissue in vivo for continuous glucose monitoring in man
Bolinder, J., Hagström, E., Ungerstedt, U., et al. (1989) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365518909089123 · Cited by 61
Dermal Interstitial Glucose as an Indicator of Ambient Glycemia
Service, F. J., O’Brien, P. C., Wise, S., Ness, S. M., & LeBlanc, S. M. (1997) · Diabetes Care · doi:10.2337/diacare.20.9.1426 · Cited by 47
Clinical review 51: Implications of the Diabetes Control and Complications Trial
Eastman, R. C., Siebert, C., Harris, M. I., & Görden, P. (1993) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.77.5.8077299 · Cited by 41
Collison, M. E., Stout, P. J., Glushko, T. S., Pokela, K. N., Mullins-Hirte, D. J., Racchini, J. R., Walter, M. A., Mecca, S. P., Rundquist, J., Allen, J. J., et al. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.9.1665 · Cited by 34
Petersen, L. J. (1999) · Clinical Physiology · doi:10.1046/j.1365-2281.1999.00174.x · Cited by 28
The Use of Microdialysis to Monitor Rapid Changes in Glucose Concentration
Summers, L. K. M., Clark, M. H. A., Humphreys, S. M., Bugler, J., & Frayn, K. N. (1999) · Hormone and Metabolic Research · doi:10.1055/s-2007-978767 · Cited by 16
Current, Emerging, and Future Trends in Metabolic Monitoring
Klonoff, D. C. (2002) · Diabetes Technology & Therapeutics · doi:10.1089/152091502320798196 · Cited by 8
Advances in continuous in vivo glucose monitoring
Leitao, E., Kaushal, K., Gill, A., & Vadgama, P. M. (2002) · Diabetic Medicine · doi:10.1046/j.1464-5491.19.s5.7.x · Cited by 4
Research works printed but not linked: 1
- 10.1210/jc.77.5.1105 · DOI
Cited by
Sorted by citations
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Wearable non-invasive epidermal glucose sensors: A review
Kim, J., Campbell, A. S., & Wang, J. (2017) · Talanta · doi:10.1016/j.talanta.2017.08.077 · Cited by 595
Non-invasive glucose monitoring technology in diabetes management: A review
Vashist, S. K. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.03.043 · Cited by 575
Simultaneous Monitoring of Sweat and Interstitial Fluid Using a Single Wearable Biosensor Platform
Kim, J., Sempionatto, J. R., Imani, S., Hartel, M. C., Barfidokht, A., Tang, G., Campbell, A. S., Mercier, P. P., & Wang, J. (2018) · Advanced Science · doi:10.1002/advs.201800880 · Cited by 534
Wearable Biosensors: An Alternative and Practical Approach in Healthcare and Disease Monitoring
Sharma, A., Badea, M., Tiwari, S., & Marty, J. (2021) · Molecules · doi:10.3390/molecules26030748 · Cited by 387
Metadata
- Authors
- Thennadil, S. N., Rennert, J. L., Wenzel, B. J., Hazen, K. H., Ruchti, T. L., & Block, M. B.
- Affiliations
- Instrumentation Metrics, Inc., Chandler, Arizona; sthennadil@imetricsinc.com
- Instrumentation Metrics, Inc., Chandler, Arizona
- Radiant Research (United States) (US)
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2001-09
- Volume
- 3
- Issue
- 3
- Pages
- 357-365
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2145770174
- Cited by
- 166
- References
- 19
- Citations by year
- 2026: 7 · 2025: 9 · 2024: 7 · 2023: 12 · 2022: 11 · 2021: 13 · 2020: 11 · 2019: 10 · 2018: 11 · 2017: 7 · 2016: 8 · 2015: 4 · 2014: 4 · 2013: 6 · 2012: 5
- FWCI
- 3.68
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Diabetes Technology & Therapeutics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Israel Science Foundation
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Dermatology › Skin Diseases and Diabetes
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Keywords
- interstitial glucose, capillary blood glucose, venous blood glucose, glycemic excursions, non-invasive glucose monitoring, diabetes mellitus, time delay
- MeSH terms
- Adult, Blood Glucose, Capillaries, Extracellular Space, Female, Glucose, Humans, Male, Regional Blood Flow, Skin, Veins, Spectroscopy, Near-Infrared
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review