Glucose Sensing in Transdermal Body Fluid Collected Under Continuous Vacuum Pressure Via Micropores in the Stratum Corneum
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Application of continuous vacuum pressure on skin perforated with tiny micropores created by a focused beam from a low-cost laser system can result in access to a clear, transdermal body fluid (TDF) for the continuous measurement of glucose in vivo. Two clinical studies were performed to assess the feasibility of this approach. In the first study, 56 diabetic subjects were porated on either the arm or abdomen, and glucose was measured in their TDF using a custom assay system contained in a patch that was affixed to the skin above the poration site. The continuous readings of glucose in TDF were compared with fingerstick blood measured every half-hour over a 2-day period, resulting in 1,167 paired data points that yielded a correlation of 0.8745 with 97.75% of the readings in the Clarke Error Grid A and B zones. In a second study, 187 diabetic and 65 nondiabetic subjects had glucose measurements from their TDF made using a commercially available glucose strip and meter. A total of 4,059 data pairs (discrete TDF and capillary blood) were collected over a 2-day period, resulting in a correlation of 0.946 with 99% of the readings in the Clarke Error Grid A and B zones. These studies indicate that TDF drawn through micropores in the stratum corneum of the skin potentially can provide a lesser invasive and continuous method of measuring glucose in diabetic individuals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Evaluating clinical accuracy of systems for self-monitoring of blood glucose
Clarke, W. L., Cox, D., Gonder-Frederick, L. A., Carter, W., & Pohl, S. L. (1987) · Diabetes Care · doi:10.2337/diacare.10.5.622 · Cited by 1,435
A subcutaneous glucose sensor with improved longevity, dynamic range, and stability of calibration.
Updike, S. J., Shults, M. C., Gilligan, B. J., & Rhodes, R. K. (2000) · Diabetes Care · doi:10.2337/diacare.23.2.208 · Cited by 135
Ellison, J. M., Stegmann, J. M., Colner, S. L., Michael, R. H., Sharma, M. K., Ervin, K. R., & Horwitz, D. L. (2002) · Diabetes Care · doi:10.2337/diacare.25.6.961 · Cited by 133 · cited 1×
“15,16 It is unclear whether the lag we observed relates more to the site or to the measurement of trans-dermal rather than capillary glucose.”
Jungheim, K., & Koschinsky, T. (2002) · Diabetes Care · doi:10.2337/diacare.25.6.956 · Cited by 114
Cited by
Current status and future potential of transdermal drug delivery
Prausnitz, M. R., Mitragotri, S., & Langer, R. (2004) · Nature Reviews Drug Discovery · doi:10.1038/nrd1304 · Cited by 1,462
Glucose sensors: a review of current and emerging technology
Oliver, N. S., Toumazou, C., Cass, A. E. G., & Johnston, D. G. (2009) · Diabetic Medicine · doi:10.1111/j.1464-5491.2008.02642.x · Cited by 584
Sampling interstitial fluid from human skin using a microneedle patch
Samant, P. P., Niedzwiecki, M. M., Raviele, N., Tran, V., Mena-Lapaix, J., Walker, D. I., Felner, E. I., Jones, D. P., Miller, G. W., & Prausnitz, M. R. (2020) · Science Translational Medicine · doi:10.1126/scitranslmed.aaw0285 · Cited by 379
Prospects and limitations of non-invasive blood glucose monitoring using near-infrared spectroscopy
Yadav, J., Rani, A., Singh, V., & Murari, B. M. (2015) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2015.01.005 · Cited by 374
Opportunities and challenges in the diagnostic utility of dermal interstitial fluid
Friedel, M., Thompson, I. A. P., Kasting, G., Polsky, R., Cunningham, D., Soh, H. T., & Heikenfeld, J. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00998-9 · Cited by 360
Metadata
- Authors
- Gebhart, S., Faupel, M., Fowler, R., Kapsner, C., Lincoln, D., McGee, V., Pasqua, J., Steed, L., Wangsness, M., Xu, F., & Vanstory, M.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2003-04
- Volume
- 5
- Issue
- 2
- Pages
- 159-166
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2176014590
- Cited by
- 69
- References
- 4
- FWCI
- 2.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Glucose Sensing in Transdermal Body Fluid Collected Under Continuous Vacuum Pressure Via Micropores in the Stratum Corneum. https://app.cochat.ai/papers/10.1089/152091503321827812
- The paper
- Gebhart, S., Faupel, M., Fowler, R., Kapsner, C., Lincoln, D., McGee, V., Pasqua, J., Steed, L., Wangsness, M., Xu, F., & Vanstory, M. (2003). Glucose Sensing in Transdermal Body Fluid Collected Under Continuous Vacuum Pressure Via Micropores in the Stratum Corneum. Diabetes Technology & Therapeutics. https://doi.org/10.1089/152091503321827812
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.