Continuous Glucose Monitoring with Glucose Sensors: Calibration and Assessment Criteria

Lodwig, Volker, Heinemann, Lutz · 2003 · Diabetes Technology & Therapeutics
Cited by 63

The DOI matches its Crossref record.

Abstract

Continuous glucose monitoring (CM) by means of minimally invasive or noninvasive glucose sensors can help to further optimize metabolic control in patients with diabetes without need for frequent capillary blood glucose measurements. Most glucose sensors measure glucose concentration in the interstitial fluid (ISF). Because of the varying conditions in this compartment, a general in vitro calibration ( = factory calibration) by the manufacturer appears not to be possible. Therefore, calibration of the sensor signal must be performed by the patient himself repeatedly. The calibration procedure can be performed by means of conventional capillary blood glucose measurements in order to transform the sensor signals obtained from the specific compartment (e.g., ISF) into "blood" glucose values. A number of aspects can influence the validity of this procedure. The relationship between changes in blood glucose and in ISF glucose, in both time and concentration dimensions, is not well understood, especially during dynamic changes. The physical lag time, which critically depends on the glucose sensor technology used, can also introduce a systematic calibration error. After the first calibration, usually performed some hours after the application of a given glucose sensor, recalibration at certain intervals is necessary. Therefore, patients should critically assess the values displayed by a CM system. In the case of implausible glucose values they should verify the results by means of a conventional capillary glucose measurement. Up to now there is no consensus on assessment criteria to be used for evaluation of CM system performance and calibration quality. Existing methods of displaying CM values against corresponding reference values, including linear regression analysis and error grid analysis, as well as numeric criteria such as System Error, Predicted Error Sum of Squares (in %), and Mean Absolute Deviation are not generally applicable to CM. It appears as if they do not allow sufficient description of data obtained with CM systems. There is a pressing need to develop novel adequate assessment criteria enabling a better characterization of CM system performance. If these were used uniformly by all manufacturers and scientists assessing CM systems, this would allow a fair comparison of the performance of different systems.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/152091503322250596

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 63

Metadata

Authors
Lodwig, V., & Heinemann, L.
Venue
Diabetes Technology & Therapeutics
Published
2003-08
Volume
5
Issue
4
Pages
572-586
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W2095569161
Cited by
63
References
0
FWCI
2.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Continuous Glucose Monitoring with Glucose Sensors: Calibration and Assessment Criteria. https://app.cochat.ai/papers/10.1089/152091503322250596
The paper
Lodwig, V., & Heinemann, L. (2003). Continuous Glucose Monitoring with Glucose Sensors: Calibration and Assessment Criteria. Diabetes Technology & Therapeutics. https://doi.org/10.1089/152091503322250596

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.