The Accuracy of the GlucoWatch ® G2 ™ Biographer in Children with Type 1 Diabetes: Results of the Diabetes Research in Children Network (DirecNet) Accuracy Study
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The accuracy of the GlucoWatch G2 Biographer (GW2B; Cygnus, Inc., Redwood City, CA) was assessed in children and adolescents with type 1 diabetes mellitus (T1DM). During a 24-h clinical research center stay, 89 children and adolescents with T1DM (3.5-17.7 years old) wore 174 GW2Bs and had frequent serum glucose determinations during the day and night and during insulin-induced hypoglycemia and meal-induced hyperglycemia, resulting in 3672 GW2B-reference glucose pairs. The median relative absolute difference between the GW2B and reference glucose values was 16% (25th, 75th percentiles = 7%, 29%). The proposed International Organisation for Standardisation criteria were met for 60% of sensor values. Accuracy was better at higher serum glucose levels than low glucose levels. Accuracy degraded slightly as the sensor aged. Time of day, subject age, gender, or body mass index did not impact GW2B accuracy. There were no cases of serious skin reactions. Although the accuracy of this generation of sensor does not approach that of current home glucose meters, the majority of sensor glucose values are within 20% of the serum glucose. This level of accuracy may be sufficient for detecting trends and modifying diabetes management. Further longitudinal outpatient studies are needed to assess the utility of the GW2B as a management tool to improve glycemic control and decrease the incidence of severe hypoglycemia in children with diabetes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Parkes, J. L., Slatin, S. L., Pardo, S., & Ginsberg, B. H. (2000) · Diabetes Care · doi:10.2337/diacare.23.8.1143 · Cited by 620
Cited by
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707
Care of Children and Adolescents With Type 1 Diabetes
Silverstein, J., Klingensmith, G., Copeland, K., Plotnick, L., Kaufman, F., Laffel, L., Deeb, L., Grey, M., Anderson, B., Holzmeister, L. A., et al. (2005) · Diabetes Care · doi:10.2337/diacare.28.1.186 · Cited by 1,312
Klonoff, D. C. (2005) · Diabetes Care · doi:10.2337/diacare.28.5.1231 · Cited by 724
Impact of Exercise on Overnight Glycemic Control in Children with Type 1 Diabetes Mellitus
Children, T. D. R. I. (2005) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2005.04.065 · Cited by 264
Overview on self-monitoring of blood glucose
Montagnana, M., Caputo, M., Giavarina, D., & Lippi, G. (2009) · Clinica Chimica Acta · doi:10.1016/j.cca.2009.01.002 · Cited by 116
Metadata
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2003-10
- Volume
- 5
- Issue
- 5
- Pages
- 791-800
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W4240664768
- Cited by
- 60
- References
- 1
- FWCI
- 6.35
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Accuracy of the GlucoWatch ® G2 ™ Biographer in Children with Type 1 Diabetes: Results of the Diabetes Research in Children Network (DirecNet) Accuracy Study. https://app.cochat.ai/papers/10.1089/152091503322526996
- The paper
- The Accuracy of the GlucoWatch ® G2 ™ Biographer in Children with Type 1 Diabetes: Results of the Diabetes Research in Children Network (DirecNet) Accuracy Study. (2003). Diabetes Technology & Therapeutics. https://doi.org/10.1089/152091503322526996
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.