Impact of Posture and Fixation Technique on Impedance Spectroscopy Used for Continuous and Noninvasive Glucose Monitoring
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Impedance spectroscopy allows for the assessment of changes in the permittivity and conductivity of erythrocyte cell membranes, induced by blood glucose variations. This study was performed to evaluate the potential influence of motion-induced microvascular blood flow variations from different forearm postures on the PENDRA (Pendragon Medical AG, Zürich, Switzerland) signal. Fifteen volunteers without diabetes were included (seven female, eight male, mean +/- SD age 33.3 +/- 9.9 years, body mass index 24.8 +/- 3.0 kg/m(2)). PENDRA devices were fixed at both upper extremities with different fixation techniques (bracelet and adhesive tape). Standardized position changes of the upper extremities were performed to induce variations in cutaneous microcirculation, which were assessed by laser-Doppler-fluxmetry with different probe temperatures on the forearm. Changes in microcirculation were seen in some of the different motion procedures: supine to hanging, 61.1 +/- 29.9 arbitrary units (AU) to 46.2 +/- 24.8 AU at 37 degrees C and 15.9 +/- 13.0 AU to 13.4 +/- 10.1 at skin temperature (P < 0.01 for both probes); supine to upright, 80.5 +/- 55.4 AU to 74.9 +/- 43.8 AU (not significant) at 37 degrees C and 18.7 +/- 16.8 AU to 20.9 +/- 16.1 AU at skin temperature (P < 0.01). An initially observed subtle influence of microcirculation variations on the impedance signal was minimized when the device was fixed by both bracelet and tape. Other influencing factors (such as temperature, local anatomy, etc.) are addressed in the complex calibration procedure. Well-educated patients might be the best candidates for first using the device for continuous glucose monitoring. They may especially benefit from the trend indication and the hypoglycemia/hyperglycemia threshold and alarm functions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Diabetes Control and Complications Trial Research Group (1995) · Diabetes · doi:10.2337/diab.44.8.968 · Cited by 1,301
Analysis: PENDRA: The Once and Future Noninvasive Continuous Glucose Monitoring Device?
Weinzimer, S. A. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/1520915041706018 · Cited by 37
Cited by
Klonoff, D. C. (2005) · Diabetes Care · doi:10.2337/diacare.28.5.1231 · Cited by 724
Glucose sensors: a review of current and emerging technology
Oliver, N. S., Toumazou, C., Cass, A. E. G., & Johnston, D. G. (2009) · Diabetic Medicine · doi:10.1111/j.1464-5491.2008.02642.x · Cited by 584
Non-invasive glucose monitoring technology in diabetes management: A review
Vashist, S. K. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.03.043 · Cited by 575
Biocompatible Materials for Continuous Glucose Monitoring Devices
Nichols, S. P., Koh, A., Storm, W. L., Shin, J. H., & Schoenfisch, M. H. (2013) · Chemical Reviews · doi:10.1021/cr300387j · Cited by 347
Comprehensive Review on Wearable Sweat-Glucose Sensors for Continuous Glucose Monitoring
Zafar, H., Channa, A., Jeoti, V., & Stojanović, G. M. (2022) · Sensors · doi:10.3390/s22020638 · Cited by 329
Metadata
- Authors
- Pfützner, A., Caduff, A., Larbig, M., Schrepfer, T., & Forst, T.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2004-08
- Volume
- 6
- Issue
- 4
- Pages
- 435-441
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2065540589
- Cited by
- 55
- References
- 2
- FWCI
- 5.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Impact of Posture and Fixation Technique on Impedance Spectroscopy Used for Continuous and Noninvasive Glucose Monitoring. https://app.cochat.ai/papers/10.1089/1520915041705839
- The paper
- Pfützner, A., Caduff, A., Larbig, M., Schrepfer, T., & Forst, T. (2004). Impact of Posture and Fixation Technique on Impedance Spectroscopy Used for Continuous and Noninvasive Glucose Monitoring. Diabetes Technology & Therapeutics. https://doi.org/10.1089/1520915041705839
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.