CoChat

Characterization and Optimization of a Red-Shifted Fluorescence Polarization ADP Detection Assay

Kleman-Leyer, Karen M., Klink, Tony A., Kopp, Andrew L., Westermeyer, Thane A., Koeff, Mark D., Larson, Brad R., Worzella, Tracy J., Pinchard, Cori A., van de Kar, Sebastianus A.T., Zaman, Guido J.R., Hornberg, Jorrit J., Lowery, Robert G. · 2009 · ASSAY and Drug Development Technologies
Cited by 41

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

ATP depletion and ADP formation are generic detection methods used for the identification of kinase and other ATP-utilizing enzyme inhibitors in high-throughput screening campaigns. However, the most widely used nucleotide detection approaches require high ATP consumption rates or involve the use of coupling enzymes, which can complicate the selection of lead compounds. As an alternative, we have developed the Transcreener ® (BellBrook Labs, Madison, WI) platform, which relies on the direct immunodetection of nucleotides. Here we describe the development of antibodies with > 100-fold selectivity for ADP versus ATP, which enable robust detection of initial velocity rates (Z ′ > 0.7 at 10% substrate consumption) at ATP concentrations ranging from 0.1 μ M to 1,000 μ M in a competitive fluorescence polarization (FP) immunoassay. Competitive binding experiments indicate similar affinities for other nucleotide diphosphates, including 2′-deoxy ADP, GDP, and UDP. The antibody-tracer complex and the red-shifted, ratiometric FP signal are stable for at least 24 h at room temperature, providing suitable conditions for high-throughput screening. A method for calculating a kinase ATP K m with this FP immunoassay is also presented. The Transcreener ADP assay provides a simple, generic assay platform for inhibitor screening and selectivity profiling that can be used for any ADP-generating enzyme.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/adt.2008.175

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Research works printed but not linked: 30

  1. 10.1023/A:1007507224529 · DOI
  2. 10.1038/nrd1066 · DOI · Paper page
  3. High Throughput Screening 2007 New Strategies Success Rates Use of Enabling Technologies. HighTech Business Decisions. San Jose: CA, 2007.
  4. Xu K, , Stern AS, , Levin W, , Chua A, , Vassilev LT. A generic time-resolved fluorescence assay for serine/threonine kinase activity: application to Cdc7/Dbf4. J Biochem Mol Biol, 2003; 36:421–425.
  5. 10.2174/138620703106298473 · DOI
  6. 10.2174/138620703106298563 · DOI
  7. 10.1177/1087057103252309 · DOI
  8. 10.1002/1522-2683(200110)22:18<4000::AID-ELPS4000>3.0.CO;2-A · doi:10.1002/1522-2683(200110)22:18<4000::aid-elps4000>3.0.co;2-a
  9. 10.1074/jbc.M209677200 · DOI · Paper page
  10. 10.1021/bi0495073 · DOI
  11. 10.1073/pnas.92.17.7686 · DOI · Paper page
  12. 10.1089/154065804323056503 · DOI
  13. 10.1089/154065804323056495 · DOI · Paper page
  14. 10.1038/nrd1063 · DOI · Paper page
  15. 10.1177/1087057106286829 · DOI
  16. 10.1073/pnas.0600445103 · DOI · Paper page
  17. 10.1517/14728222.10.1.179 · DOI
  18. 10.1177/1087057107300221 · DOI
  19. 10.1074/jbc.M304481200 · DOI · Paper page
  20. 10.1089/adt.2006.045 · DOI
  21. 10.1177/108705719900400206 · DOI · Paper page
  22. 10.1016/0005-2787(81)90204-5 · doi:10.1016/0005-2787(81)90204-5
  23. Richman RA, , Kopf GS, , Hamet P, , Johnson RA. Preparation of cyclic nucleotide antisera with thyroglobulin-cyclic nucleotide conjugates. J Cyclic Nucleotide Res, 1980; 6:461–468.
  24. 10.1016/j.chembiol.2005.04.011 · DOI · Paper page
  25. 10.1177/1087057108319864 · DOI
  26. Zalameda LP, , Liu Y, , McCarter JD. Application of high throughput fluorescence polarization-based ADP assay for an ATP-dependent group transferase. Poster presented at IBC's 12th Annual DDT World Congress: Building Your Drug Pipeline, August 2007, Boston, MA.
  27. 10.1016/S0161-5890(99)00133-9 · doi:10.1016/s0161-5890(99)00133-9
  28. 10.1074/jbc.271.51.32612 · DOI
  29. 10.1089/154065804323056530 · DOI
  30. 10.1021/jm701301m · DOI · Paper page

Cited by

Metadata

Authors
Kleman-Leyer, K. M., Klink, T. A., Kopp, A. L., Westermeyer, T. A., Koeff, M. D., Larson, B. R., Worzella, T. J., Pinchard, C. A., van de Kar, S. A. T., Zaman, G. J. R., Hornberg, J. J., & Lowery, R. G.
Affiliations
  • BellBrook Labs
  • Schering-Plough Research Institute
Venue
ASSAY and Drug Development Technologies
Published
2009-02
Volume
7
Issue
1
Pages
56-67
ISSN
  • 1540-658X
  • 1557-8127
Cited by
41
References
3
Language
en
Licence

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.