Characterization and Optimization of a Red-Shifted Fluorescence Polarization ADP Detection Assay
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
ATP depletion and ADP formation are generic detection methods used for the identification of kinase and other ATP-utilizing enzyme inhibitors in high-throughput screening campaigns. However, the most widely used nucleotide detection approaches require high ATP consumption rates or involve the use of coupling enzymes, which can complicate the selection of lead compounds. As an alternative, we have developed the Transcreener ® (BellBrook Labs, Madison, WI) platform, which relies on the direct immunodetection of nucleotides. Here we describe the development of antibodies with > 100-fold selectivity for ADP versus ATP, which enable robust detection of initial velocity rates (Z ′ > 0.7 at 10% substrate consumption) at ATP concentrations ranging from 0.1 μ M to 1,000 μ M in a competitive fluorescence polarization (FP) immunoassay. Competitive binding experiments indicate similar affinities for other nucleotide diphosphates, including 2′-deoxy ADP, GDP, and UDP. The antibody-tracer complex and the red-shifted, ratiometric FP signal are stable for at least 24 h at room temperature, providing suitable conditions for high-throughput screening. A method for calculating a kinase ATP K m with this FP immunoassay is also presented. The Transcreener ADP assay provides a simple, generic assay platform for inhibitor screening and selectivity profiling that can be used for any ADP-generating enzyme.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The Terbium labeled ADP antibody selectively binds HiLyte647 labeled ADP tracer in the presence of ATP, with an approximate 100-fold selectivity for ADP over ATP.33”
From Development of a sensitive assay for SERCA activity using FRET detection of ADP (2014) · cites this paper as [33]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Protein kinases — the major drug targets of the twenty-first century?
Cohen, P. (2002) · Nature Reviews Drug Discovery · doi:10.1038/nrd773 · Cited by 2,186
Gibon, Y., Blaesing, O. E., Hannemann, J., Carillo, P., Höhne, M., Hendriks, J. H. M., Palacios, N., Cross, J., Selbig, J., & Stitt, M. (2004) · The Plant Cell · doi:10.1105/tpc.104.025973 · Cited by 552
Tomiya, N., Ailor, E., Lawrence, S. M., Betenbaugh, M. J., & Lee, Y. C. (2001) · Analytical Biochemistry · doi:10.1006/abio.2001.5091 · Cited by 203
Research works printed but not linked: 30
- 10.1023/A:1007507224529 · DOI
- 10.1038/nrd1066 · DOI · Paper page
- High Throughput Screening 2007 New Strategies Success Rates Use of Enabling Technologies. HighTech Business Decisions. San Jose: CA, 2007.
- Xu K, , Stern AS, , Levin W, , Chua A, , Vassilev LT. A generic time-resolved fluorescence assay for serine/threonine kinase activity: application to Cdc7/Dbf4. J Biochem Mol Biol, 2003; 36:421–425.
- 10.2174/138620703106298473 · DOI
- 10.2174/138620703106298563 · DOI
- 10.1177/1087057103252309 · DOI
- 10.1002/1522-2683(200110)22:18<4000::AID-ELPS4000>3.0.CO;2-A · doi:10.1002/1522-2683(200110)22:18<4000::aid-elps4000>3.0.co;2-a
- 10.1074/jbc.M209677200 · DOI · Paper page
- 10.1021/bi0495073 · DOI
- 10.1073/pnas.92.17.7686 · DOI · Paper page
- 10.1089/154065804323056503 · DOI
- 10.1089/154065804323056495 · DOI · Paper page
- 10.1038/nrd1063 · DOI · Paper page
- 10.1177/1087057106286829 · DOI
- 10.1073/pnas.0600445103 · DOI · Paper page
- 10.1517/14728222.10.1.179 · DOI
- 10.1177/1087057107300221 · DOI
- 10.1074/jbc.M304481200 · DOI · Paper page
- 10.1089/adt.2006.045 · DOI
- 10.1177/108705719900400206 · DOI · Paper page
- 10.1016/0005-2787(81)90204-5 · doi:10.1016/0005-2787(81)90204-5
- Richman RA, , Kopf GS, , Hamet P, , Johnson RA. Preparation of cyclic nucleotide antisera with thyroglobulin-cyclic nucleotide conjugates. J Cyclic Nucleotide Res, 1980; 6:461–468.
- 10.1016/j.chembiol.2005.04.011 · DOI · Paper page
- 10.1177/1087057108319864 · DOI
- Zalameda LP, , Liu Y, , McCarter JD. Application of high throughput fluorescence polarization-based ADP assay for an ATP-dependent group transferase. Poster presented at IBC's 12th Annual DDT World Congress: Building Your Drug Pipeline, August 2007, Boston, MA.
- 10.1016/S0161-5890(99)00133-9 · doi:10.1016/s0161-5890(99)00133-9
- 10.1074/jbc.271.51.32612 · DOI
- 10.1089/154065804323056530 · DOI
- 10.1021/jm701301m · DOI · Paper page
Cited by
Fluorescence polarization assays in small molecule screening
Lea, W. A., & Simeonov, A. (2011) · Expert Opinion on Drug Discovery · doi:10.1517/17460441.2011.537322 · Cited by 379
Analysis of protein-ligand interactions by fluorescence polarization
Rossi, A. M., & Taylor, C. W. (2011) · Nature Protocols · doi:10.1038/nprot.2011.305 · Cited by 357
High-Throughput Metabolic Engineering: Advances in Small-Molecule Screening and Selection
Dietrich, J. A., McKee, A. E., & Keasling, J. D. (2010) · Annual Review of Biochemistry · doi:10.1146/annurev-biochem-062608-095938 · Cited by 322
Kimple, A. J., Bosch, D. E., Giguère, P. M., & Siderovski, D. P. (2011) · Pharmacological Reviews · doi:10.1124/pr.110.003038 · Cited by 230
“…activity without the use of radioactivity, a monoclonal antibody and fluorescent tracer system, previously developed by Bellbrook Labs for their Transcreener ADP assay (Kleman-Leyer et al., 2009), was adapted for selective immunodetection of GDP with a fluorescence polarization (FP) readout (Fig.”
MethodAcker, M. G., & Auld, D. S. (2014) · Perspectives in Science · doi:10.1016/j.pisc.2013.12.001 · Cited by 213
Phosphatase-Coupled Universal Kinase Assay and Kinetics for First-Order-Rate Coupling Reaction
Wu, Z. L. (2011) · PLoS ONE · doi:10.1371/journal.pone.0023172 · Cited by 28
Development of a sensitive assay for SERCA activity using FRET detection of ADP
Jing, M., Verardi, R., Veglia, G., & Bowser, M. T. (2014) · Anal. Methods · doi:10.1039/c3ay41808a · Cited by 3
Metadata
- Authors
- Kleman-Leyer, K. M., Klink, T. A., Kopp, A. L., Westermeyer, T. A., Koeff, M. D., Larson, B. R., Worzella, T. J., Pinchard, C. A., van de Kar, S. A. T., Zaman, G. J. R., Hornberg, J. J., & Lowery, R. G.
- Affiliations
- BellBrook Labs
- Schering-Plough Research Institute
- Venue
- ASSAY and Drug Development Technologies
- Publisher
- SAGE Publications
- Published
- 2009-02
- Volume
- 7
- Issue
- 1
- Pages
- 56-67
- ISSN
- 1540-658X
- 1557-8127
- Cited by
- 41
- References
- 3
- Language
- en
- Licence
- creativecommons.org/licenses/by/4.0/ (vor)
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.