CoChat

Human and Methodological Sources of Variability in the Measurement of Urinary 8-Oxo-7,8-dihydro-2′-deoxyguanosine

Open access
Barregard, Lars, Møller, Peter, Henriksen, Trine, Mistry, Vilas, Koppen, Gudrun, Rossner, Pavel, Sram, Radim J., Weimann, Allan, Poulsen, Henrik E., Nataf, Robert, Andreoli, Roberta, Manini, Paola, Marczylo, Tim, Lam, Patricia, Evans, Mark D., Kasai, Hiroshi, Kawai, Kazuaki, Li, Yun-Shan, Sakai, Kazuo, Singh, Rajinder, Teichert, Friederike, Farmer, Peter B., Rozalski, Rafal, Gackowski, Daniel, Siomek, Agnieszka, Saez, Guillermo T., Cerda, Concha, Broberg, Karin, Lindh, Christian, Hossain, Mohammad Bakhtiar, Haghdoost, Siamak, Hu, Chiung-Wen, Chao, Mu-Rong, Wu, Kuen-Yuh, Orhan, Hilmi, Senduran, Nilufer, Smith, Raymond J., Santella, Regina M., Su, Yali, Cortez, Czarina, Yeh, Susan, Olinski, Ryszard, Loft, Steffen, Cooke, Marcus S. · 2013 · Antioxidants & Redox Signaling
Cited by 157

The DOI matches its Crossref record.

Abstract

AIMS: Urinary 8-oxo-7,8-dihydro-2'-deoxyguanosine (8-oxodG) is a widely used biomarker of oxidative stress. However, variability between chromatographic and ELISA methods hampers interpretation of data, and this variability may increase should urine composition differ between individuals, leading to assay interference. Furthermore, optimal urine sampling conditions are not well defined. We performed inter-laboratory comparisons of 8-oxodG measurement between mass spectrometric-, electrochemical- and ELISA-based methods, using common within-technique calibrants to analyze 8-oxodG-spiked phosphate-buffered saline and urine samples. We also investigated human subject- and sample collection-related variables, as potential sources of variability. RESULTS: Chromatographic assays showed high agreement across urines from different subjects, whereas ELISAs showed far more inter-laboratory variation and generally overestimated levels, compared to the chromatographic assays. Excretion rates in timed 'spot' samples showed strong correlations with 24 h excretion (the 'gold' standard) of urinary 8-oxodG (rp 0.67-0.90), although the associations were weaker for 8-oxodG adjusted for creatinine or specific gravity (SG). The within-individual excretion of 8-oxodG varied only moderately between days (CV 17% for 24 h excretion and 20% for first void, creatinine-corrected samples). INNOVATION: This is the first comprehensive study of both human and methodological factors influencing 8-oxodG measurement, providing key information for future studies with this important biomarker. CONCLUSION: ELISA variability is greater than chromatographic assay variability, and cannot determine absolute levels of 8-oxodG. Use of standardized calibrants greatly improves intra-technique agreement and, for the chromatographic assays, importantly allows integration of results for pooled analyses. If 24 h samples are not feasible, creatinine- or SG-adjusted first morning samples are recommended.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/ars.2012.4714

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 157

Metadata

Authors
Barregard, L., Møller, P., Henriksen, T., Mistry, V., Koppen, G., Rossner, P., Sram, R. J., Weimann, A., Poulsen, H. E., Nataf, R., Andreoli, R., Manini, P., Marczylo, T., Lam, P., Evans, M. D., Kasai, H., Kawai, K., Li, Y.-S., Sakai, K., Singh, R., Teichert, F., Farmer, P. B., Rozalski, R., Gackowski, D., Siomek, A., Saez, G. T., Cerda, C., Broberg, K., Lindh, C., Hossain, M. B., Haghdoost, S., Hu, C.-W., Chao, M.-R., Wu, K.-Y., Orhan, H., Senduran, N., Smith, R. J., Santella, R. M., Su, Y., Cortez, C., Yeh, S., Olinski, R., Loft, S., & Cooke, M. S.
Venue
Antioxidants & Redox Signaling
Published
2013-06-20
Volume
18
Issue
18
Pages
2377-2391
ISSN
  • 1523-0864 (ISSN-L)
  • 1557-7716
OpenAlex
W1989103032
Cited by
157
References
0
FWCI
6.54
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Human and Methodological Sources of Variability in the Measurement of Urinary 8-Oxo-7,8-dihydro-2′-deoxyguanosine. https://app.cochat.ai/papers/10.1089/ars.2012.4714
The paper
Barregard, L., Møller, P., Henriksen, T., Mistry, V., Koppen, G., Rossner, P., Sram, R. J., Weimann, A., Poulsen, H. E., Nataf, R., Andreoli, R., Manini, P., Marczylo, T., Lam, P., Evans, M. D., Kasai, H., Kawai, K., Li, Y.-S., Sakai, K., . . . Cooke, M. S. (2013). Human and Methodological Sources of Variability in the Measurement of Urinary 8-Oxo-7,8-dihydro-2′-deoxyguanosine. Antioxidants & Redox Signaling. https://doi.org/10.1089/ars.2012.4714

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.