Strengths and Weaknesses of a Planar Whole-Body Method of 153 Sm Dosimetry for Patients with Metastatic Osteosarcoma and Comparison with Three-Dimensional Dosimetry
Open accessAbstract
PURPOSE: Dosimetric accuracy depends directly upon the accuracy of the activity measurements in tumors and organs. The authors present the methods and results of a retrospective tumor dosimetry analysis in 14 patients with a total of 28 tumors treated with high activities of (153)Sm-ethylenediaminetetramethylenephosphonate ((153)Sm-EDTMP) for therapy of metastatic osteosarcoma using planar images and compare the results with three-dimensional dosimetry. MATERIALS AND METHODS: Analysis of phantom data provided a complete set of parameters for dosimetric calculations, including buildup factor, attenuation coefficient, and camera dead-time compensation. The latter was obtained using a previously developed methodology that accounts for the relative motion of the camera and patient during whole-body (WB) imaging. Tumor activity values calculated from the anterior and posterior views of WB planar images of patients treated with (153)Sm-EDTMP for pediatric osteosarcoma were compared with the geometric mean value. The mean activities were integrated over time and tumor-absorbed doses were calculated using the software package OLINDA/EXM. RESULTS: The authors found that it was necessary to employ the dead-time correction algorithm to prevent measured tumor activity half-lives from often exceeding the physical decay half-life of (153)Sm. Measured half-lives so long are unquestionably in error. Tumor-absorbed doses varied between 0.0022 and 0.27 cGy/MBq with an average of 0.065 cGy/MBq; however, a comparison with absorbed dose values derived from a three-dimensional analysis for the same tumors showed no correlation; moreover, the ratio of three-dimensional absorbed dose value to planar absorbed dose value was 2.19. From the anterior and posterior activity comparisons, the order of clinical uncertainty for activity and dose calculations from WB planar images, with the present methodology, is hypothesized to be about 70%. CONCLUSION: The dosimetric results from clinical patient data indicate that absolute planar dosimetry is unreliable and dosimetry using three-dimensional imaging is preferable, particularly for tumors, except perhaps for the most sophisticated planar methods. The relative activity and patient kinetics derived from planar imaging show a greater level of reliability than the dosimetry.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Assessments of dose, response, and toxicity are only as good as the estimation of activity concentration in a particular organ volume.
“Assessments of dose/response/toxicity are only as good as the estimation of activity concentration in particular organ volume ( 15 ).”
From Normal-Tissue Tolerance to Radiopharmaceutical Therapies, the Knowns and the Unknowns (2021) · cites this paper as [15]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stabin, M. G., Sparks, R. B., & Crowe, E. A. (2005) · PubMed · Cited by 1,340
Reporting and analyzing dose distributions: A concept of equivalent uniform dose
Niemierko, A. (1997) · Medical Physics · doi:10.1118/1.598063 · Cited by 1,231
Siegel, J. A., Thomas, S. R., Stubbs, J. B., Mg, S., Hays, M. T., Koral, K. F., Robertson, J. S., Howell, R. W., Wessels, B. W., Fisher, D. R., et al. (1999) · PubMed · Cited by 572
Improved SPECT quantification using compensation for scattered photons.
Jaszczak, R. J., Kl, G., Floyd, C. E., et al. (1984) · PubMed · Cited by 559
Serafini, A. N., Houston, S. J., Resche, I., Quick, D. P., Grund, F. M., Ell, P. J., Bertrand, A., Ahmann, F. R., Orihuela, E., Reid, R. H., et al. (1998) · Journal of Clinical Oncology · doi:10.1200/jco.1998.16.4.1574 · Cited by 435
Dewaraja, Y. K., Frey, E. C., Sgouros, G., Brill, A. B., Roberson, P. L., ZANZONICO, P. B., & Ljungberg, M. H. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.100123 · Cited by 419
Self-citationSartor, O. A., Reid, R. H., Hoskin, P., Quick, D. P., Ell, P. J., Coleman, R. E., Kotler, J., Freeman, L. M., & Olivier, P. (2004) · Urology · doi:10.1016/j.urology.2004.01.034 · Cited by 362
Sgouros, G., Kolbert, K. S., Sheikh, A., Pentlow, K. S., Mun, E. F., Barth, A., Robbins, R. J., & Larson, S. M. (2004) · PubMed · Cited by 308
Self-citationResche, I., Chatal, J., Pecking, A. P., Ell, P. J., Duchesne, G. M., Rubens, R. D., Fogelman, I., Houston, S., Fauser, A. A., Fischer, M., et al. (1997) · European Journal of Cancer · doi:10.1016/s0959-8049(97)00155-x · Cited by 252
Development of radioimmunotherapeutic and diagnostic antibodies: an inside-out view
Boswell, C. A., & Brechbiel, M. W. (2007) · Nuclear Medicine and Biology · doi:10.1016/j.nucmedbio.2007.04.001 · Cited by 245
Samarium-153-EDTMP biodistribution and dosimetry estimation.
Eary, J. F., Collins, C., Stabin, M., Vernon, C. B., Petersdorf, S. H., Baker, M., Hartnett, S. D., Ferency, S., Addison, S. J., & Appelbaum, F. R. (1993) · PubMed · Cited by 225
In vivo quantitation of lesion radioactivity using external counting methods
Thomas, S. R., Maxon, H. R., & Kereiakes, J. G. (1976) · Medical Physics · doi:10.1118/1.594287 · Cited by 187
Anderson, P. M. (2002) · Journal of Clinical Oncology · doi:10.1200/jco.20.1.189 · Cited by 175
Fizazi, K. S., Beuzeboc, P., Lumbroso, J., Haddad, V., Massard, C., Gross‐Goupil, M., Palma, M. D., Escudier, B. J., Théodore, C., Loriot, Y., et al. (2009) · Journal of Clinical Oncology · doi:10.1200/jco.2008.18.9811 · Cited by 173
Prideaux, A. R., Song, H., Hobbs, R. F., He, B., Frey, E. C., Ladenson, P. W., Wahl, R. L., & Sgouros, G. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.106.038000 · Cited by 145
Self-citationPediatric Soft Tissue Sarcomas
Loeb, D. M., Thornton, K. A., & Shokek, O. (2008) · Surgical Clinics of North America · doi:10.1016/j.suc.2008.03.008 · Cited by 135
Self-citationDosimetry and toxicity of samarium-153-EDTMP administered for bone pain due to skeletal metastases.
Bayouth, J. E., Macey, D. J., Kasi, L. P., et al. (1994) · PubMed · Cited by 132
The Impact of PET and SPECT on Dosimetry for Targeted Radionuclide Therapy
Flux, G., Bardiès, M., Monsieurs, M. A., et al. (2006) · Zeitschrift für Medizinische Physik · doi:10.1078/0939-3889-00291 · Cited by 128
Buvat, I., Rodríguez‐Villafuerte, M., Todd-Pokropek, A. E., et al. (1995) · PubMed · Cited by 125
Sartor, O. A., Reid, R. H., Bushnell, D. L., et al. (2006) · Cancer · doi:10.1002/cncr.22431 · Cited by 122
Anderson, P. M., Wiseman, G. A., Dispenzieri, A. A., et al. (2002) · Journal of Clinical Oncology · doi:10.1200/jco.2002.20.1.189 · Cited by 119
The Role of Radiation Therapy in the Management of Sarcomas
Kaushal, A., & Citrin, D. E. (2008) · Surgical Clinics of North America · doi:10.1016/j.suc.2008.03.005 · Cited by 101
Morris, M. J., Pandit-Taskar, N. D., Carrasquillo, J. A., Divgi, C. R., Slovin, S. F., Kelly, W. K., Rathkopf, D. E., Gignac, G. A., Solit, D. B., Schwartz, L. H., et al. (2009) · Journal of Clinical Oncology · doi:10.1200/jco.2008.20.4164 · Cited by 101
Dewaraja, Y. K., Schipper, M. J., Roberson, P. L., et al. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.075176 · Cited by 94
Three-Dimensional Imaging-Based Radiobiological Dosimetry
Sgouros, G., Frey, E. C., Wahl, R. L., He, B., Prideaux, A. R., & Hobbs, R. F. (2008) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2008.05.008 · Cited by 92
Self-citationHobbs, R. F., Wahl, R. L., Lodge, M. A., et al. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.066738 · Cited by 85
Self-citationGemcitabine Radiosensitization after High-Dose Samarium for Osteoblastic Osteosarcoma
Anderson, P. M., Wiseman, G. A., Erlandson, L., Rodriguez, V., Trotz, B. A., Dubansky, S. A., & Albritton, K. H. (2005) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-05-0628 · Cited by 82
Tumor uptake as a function of tumor mass: a mathematic model.
Williams, L. E., Duda, R. B., Proffitt, R. T., et al. (1988) · PubMed · Cited by 81
He, B., & Frey, E. C. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/16/006 · Cited by 74
Bardiès, M., Bardet, S., Faivre-Chauvet, A., et al. (1996) · PubMed · Cited by 55
He, B., Du, Y., Segars, W. P., et al. (2009) · Medical Physics · doi:10.1118/1.3063156 · Cited by 54
He, B., Wahl, R. L., Du, Y., Sgouros, G., Jacene, H., Flinn, I., & Frey, E. C. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.908131 · Cited by 53
Self-citationDose‐finding study of 153Sm‐EDTMP in patients with poor‐prognosis osteosarcoma
Loeb, D. M., Garrett-Mayer, E. S., Hobbs, R. F., et al. (2009) · Cancer · doi:10.1002/cncr.24286 · Cited by 53
Self-citationHobbs, R. F., McNutt, T., Baechler, S., He, B., Esaias, C. E., Frey, E. C., Loeb, D. M., Wahl, R. L., Shokek, O., & Sgouros, G. (2011) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2010.08.022 · Cited by 53
Self-citationThe buildup factor: effect of scatter on absolute volume determination.
Siegel, J. A., Wu, R. K., & Maurer, A. H. (1985) · PubMed · Cited by 50
Dispenzieri, A. A., Wiseman, G., Lacy, M. Q., Litzow, M. R., Anderson, P. M., Gastineau, D. A., Tefferi, A., Inwards, D. J., Micallef, I. N., Ansell, S. M., et al. (2004) · Leukemia · doi:10.1038/sj.leu.2403575 · Cited by 50
Brenner, W., Kampen, W. U., Kampen, A. M., et al. (2001) · PubMed · Cited by 48
Senthamizhchelvan, S., Hobbs, R. F., Hong, S., Frey, E. C., Zhang, Z., Armour, E. P., Wahl, R. L., Loeb, D. M., & Sgouros, G. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.096677 · Cited by 41
Self-citationThe Role of Radiation Treatment in the Contemporary Management of Bone Tumors
Hristov, B. H., Shokek, O., & Frassica, D. A. (2007) · Journal of the National Comprehensive Cancer Network · doi:10.6004/jnccn.2007.0040 · Cited by 32
Loeb, D. M., Hobbs, R. F., Okoli, A., et al. (2010) · Cancer · doi:10.1002/cncr.25518 · Cited by 31
Self-citationHe, B., Wahl, R. L., Sgouros, G., et al. (2009) · Medical Physics · doi:10.1118/1.3100265 · Cited by 30
Self-citationStrigari, L., Sciuto, R., D’Andrea, M., et al. (2007) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-006-0302-4 · Cited by 18
ICRU Report 67: Absorbed-Dose Specification in Nuclear Medicine,
Kearfott, K. J. (2003) · Health Physics · doi:10.1097/00004032-200307000-00023 · Cited by 16
Delpon, G., Ferrer, L., Lenta, C., et al. (2002) · Cancer · doi:10.1002/cncr.10289 · Cited by 15
Song, N., He, B., Wahl, R. L., et al. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/17/004 · Cited by 14
Self-citationDosimetry considerations of bone‐seeking radionuclides for marrow ablation
Bayouth, J. E., & Macey, D. J. (1993) · Medical Physics · doi:10.1118/1.597005 · Cited by 13
A gamma camera count rate saturation correction method for whole-body planar imaging
Hobbs, R. F., Baechler, S., Senthamizhchelvan, S., et al. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/3/018 · Cited by 13
Self-citationParameters Influencing Volume and Activity Quantitation in Spect
Gleisner, K. S., Ljungberg, M. H., & Strand, S.-E. (1996) · Acta Oncologica · doi:10.3109/02841869609101649 · Cited by 12
Essman, S. C., Lewis, M. R., & Miller, W. H. (2005) · PubMed · Cited by 12
Estimates of Radiation-Absorbed Dose to Kidneys in Patients Treated with 90 Y-Ibritumomab Tiuxetan
Baechler, S., Hobbs, R. F., Prideaux, A. R., et al. (2008) · Cancer Biotherapy and Radiopharmaceuticals · doi:10.1089/cbr.2008.0506 · Cited by 9
Self-citationKendler, D., Donnemiller, E., Oberladstätter, M., et al. (2004) · Nuclear Medicine Communications · doi:10.1097/00006231-200404000-00009 · Cited by 7
A statistical analysis of the initial biodistribution of 153Sm-EDTMP in a canine
Galiano, E., & Stradiotto, M. (2005) · Applied Radiation and Isotopes · doi:10.1016/j.apradiso.2005.01.006 · Cited by 5
Essman, S. C., Lewis, M. R., & Fox, D. B. (2008) · Nuclear Medicine and Biology · doi:10.1016/j.nucmedbio.2007.11.005 · Cited by 4
Sm-153 EDTMP for recurrent metastatic osteosarcoma.
Welsh, J. S., Thurman, S. A., Borzillary, S., et al. (2003) · PubMed · Cited by 3
Flagged first, then by citations
Research works printed but not linked: 14
- Jaszczak RJ, 1984, J Nucl Med, 25, 893
- Siegel JA, 1985, J Nucl Med, 26, 390
- Buvat I, 1995, J Nucl Med, 36, 1476
- Bardies M, 1996, J Nucl Med, 37, 1853
- Essman SC, 2005, J Nucl Med, 46, 2076
- Brenner W, 2001, J Nucl Med, 42, 230
- Eary JF, 1993, J Nucl Med, 34, 1031
- Bayouth JE, 1994, J Nucl Med, 35, 63
- Hobbs RF, European Association of Nuclear Medicine Annual Meeting Abstracts
- Siegel JA, 1999, J Nucl Med, 40, 37S
- Stabin MG, 2005, J Nucl Med, 46, 1023
- Williams LE, 1988, J Nucl Med, 29, 103
- Sgouros G, 2004, J Nucl Med, 45, 1366
- Welsh JS, 2003, Clin Adv Hematol Oncol, 1, 181
Cited by
Sorted by citations
Normal-Tissue Tolerance to Radiopharmaceutical Therapies, the Knowns and the Unknowns
Wahl, R. L., Sgouros, G., Iravani, A., Jacene, H., Pryma, D., Saboury, B., Capala, J., & Graves, S. A. (2021) · Journal of Nuclear Medicine · doi:10.2967/jnumed.121.262751 · Cited by 95
Self-citation
Metadata
- Authors
- Plyku, D., Loeb, D. M., Prideaux, A. R., Baechler, S., Wahl, R. L., Sgouros, G., & Hobbs, R. F.
- Affiliations
- Johns Hopkins University (US)
- Institute of Radiation Physics (CH)
- Corresponding author
- Hobbs, Robert F.
- Venue
- Cancer Biotherapy and Radiopharmaceuticals
- Publisher
- SAGE Publications
- Published
- 2015-11
- Volume
- 30
- Issue
- 9
- Pages
- 369-379
- ISSN
- 1084-9785 (ISSN-L)
- 1557-8852
- PMC
- PMC4652159
- OpenAlex
- W2227230075
- Cited by
- 10
- References
- 54
- Citations by year
- 2022: 3 · 2021: 1 · 2020: 1 · 2019: 1 · 2017: 2 · 2016: 2
- FWCI
- 1.08
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Cancer Biotherapy and Radiopharmaceuticals (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Digital Commons@Becker (Washington University School of Medicine) (submittedVersion)
- IRIS (submittedVersion)
- SERVAL (Université de Lausanne) (submittedVersion)
- Funders
- National Institutes of Health
- National Cancer Institute (R01CA116477, R01CA163870)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiopharmaceutical Chemistry and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Keywords
- samarium-153, 153Sm-EDTMP, metastatic osteosarcoma, tumor dosimetry, 3D dosimetry, dead time correction, absorbed dose, OLINDA/EXM, pediatric osteosarcoma
- MeSH terms
- Adolescent, Adult, Algorithms, Bone Neoplasms, Child, Female, Humans, Male, Organometallic Compounds, Organophosphorus Compounds, Radiometry, Radionuclide Imaging, Radiotherapy Planning, Computer-Assisted, Retrospective Studies, Osteosarcoma, Reproducibility of Results, Phantoms, Imaging, Radiopharmaceuticals, Imaging, Three-Dimensional, Whole Body Imaging, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review