Continuous Subcutaneous Insulin Infusion and Multiple Dose of Insulin Regimen Display Similar Patterns of Blood Glucose Excursions in Pediatric Type 1 Diabetes
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Continuous subcutaneous insulin infusion (CSII) is believed to decrease glycemic variability and clinical hypoglycemia compared with the multiple daily insulin (MDI) regimen. To compare the indices of glycemic instability between CSII and MDI, we analyzed the continuous glucose monitoring system (CGMS) (Medtronic MiniMed, Northridge, CA) profiles of a group of children with type 1 diabetes mellitus with history of frequent blood glucose (BG) fluctuations and hypoglycemia. PATIENTS AND METHODS: Data from 14 (nine girls, five boys) patients (3.9-16.8 years old) on CSII and 14 age- and sex-matched (nine girls, five boys) patients (3.9-16.0 years old) on MDI with similar glycemic control (hemoglobin A1c: 7.9 +/- 1.0% vs. 7.9 +/- 1.5%) and body mass index (BMI) (20.1 +/- 4.3 vs. 19.9 +/- 4.1 kg/m(2)) were evaluated by the CGMS. Mean BG (MBG), absolute means of daily differences (MODD), mean amplitude of glycemic excursion (MAGE), and number of hypoglycemic events (BG <60 mg/dL) for 48 h were calculated. RESULTS: The MBG, MODD, MAGE, and number and mean duration of hypoglycemia events in the CSII group were similar to those in the MDI group. The MAGE had an inverse correlation with age (CSII: r (2) = 0.52, P = 0.003; MDI: r (2) = 0.29, P < 0.04) and BMI (CSII: r (2) = 0.38, P < 0.02; MDI: r (2) = 0.71, P < 0.0002). However, there was a positive relationship between MAGE and bolus:basal insulin ratio in the CSII (r (2) = 0.28, P < 0.05) and MDI (r (2) = 0.33, P < 0.03) groups. Also, the MAGE had a positive correlation with frequency of hypoglycemic events in the CSII (r (2) = 0.44, P < 0.01) and MDI (r (2) = 0.35, P < 0.03) groups. CONCLUSIONS: The CSII and MDI regimens in children and adolescents with comparable glycemic control displayed similar patterns of glycemic excursions, implying that factors influencing glycemic instability in pediatric type 1 diabetes mellitus appear to be independent of treatment modality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ratner, R. E., Hirsch, I. B., Neifing, J. L., Garg, S. K., Mecca, T. E., & Wilson, C. A. (2000) · Diabetes Care · doi:10.2337/diacare.23.5.639 · Cited by 455
Doyle (Boland), E. A., Weinzimer, S. A., Steffen, A. T., Ahern, J. A. H., Vincent, M., & Tamborlane, W. V. (2004) · Diabetes Care · doi:10.2337/diacare.27.7.1554 · Cited by 373
Binder, C., Lauritzen, T., Faber, O., & Pramming, S. (1984) · Diabetes Care · doi:10.2337/diacare.7.2.188 · Cited by 341
Bode, B. W., Gross, T. M., Thornton, K. R., & Mastrototaro, J. J. (1999) · Diabetes Research and Clinical Practice · doi:10.1016/s0168-8227(99)00113-8 · Cited by 232
A Pilot Study of the Continuous Glucose Monitoring System
Kaufman, F. R., Gibson, L. C., Halvorson, M., Carpenter, S., Fisher, L. K., & Pitukcheewanont, P. (2001) · Diabetes Care · doi:10.2337/diacare.24.12.2030 · Cited by 224
Rabasa-Lhoret, R., Garon, J., Langelier, H., Poisson, D., & Chiasson, J. L. (1999) · Diabetes Care · doi:10.2337/diacare.22.5.667 · Cited by 210
Alemzadeh, R., Ellis, J. N., Holzum, M. K., Parton, E. A., & Wyatt, D. T. (2004) · Pediatrics · doi:10.1542/peds.114.1.e91 · Cited by 63
Self-citationTrischitta, V., Brunetti, A., Chiavetta, A., Benzi, L., Papa, V., & Vigneri, R. (1989) · Diabetes · doi:10.2337/diab.38.12.1579 · Cited by 61
Glycemic Parameters with Multiple Daily Injections Using Insulin Glargine Versus Insulin Pump
Garg, S. K., Walker, A. J., Hoff, H. K., D'Souza, A. O., Gottlieb, P. A., & Chase, H. P. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/152091504322783350 · Cited by 60
Burge, M. R., & Schade, D. S. (1997) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/s0889-8529(05)70268-1 · Cited by 48
Cited by
Misso, M. L., Egberts, K. J., Page, M., O'Connor, D., & Shaw, J. (2010) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd005103.pub2 · Cited by 406
Use of Insulin Pump Therapy in the Pediatric Age-Group
Phillip, M., Battelino, T., Rodriguez, H., Danne, T., Kaufman, F., & participants, F. T. C. F. (2007) · Diabetes Care · doi:10.2337/dc07-9922 · Cited by 316
Sensor-Augmented Insulin Pump Therapy: Results of the First Randomized Treat-to-Target Study
Hirsch, I. B., Abelseth, J., Bode, B. W., Fischer, J. S., Kaufman, F. R., Mastrototaro, J., Parkin, C. G., Wolpert, H. A., & Buckingham, B. A. (2008) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0068 · Cited by 297
Pańkowska, E., Błazik, M., Dziechciarz, P., Szypowska, A., & Szajewska, H. (2009) · Pediatric Diabetes · doi:10.1111/j.1399-5448.2008.00440.x · Cited by 209
“Three of these studies (20, 23, 24) found no significant difference between the groups.”
BackgroundInfluentialGlycemic Parameters with Multiple Daily Injections Using Insulin Glargine Versus Insulin Pump
Garg, S. K., Walker, A. J., Hoff, H. K., D'Souza, A. O., Gottlieb, P. A., & Chase, H. P. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/152091504322783350 · Cited by 60
Petrofsky, J. S. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500319 · Cited by 44
Metadata
- Authors
- Alemzadeh, R., Palma-Sisto, P., Parton, E. A., & Holzum, M. K.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2005-08
- Volume
- 7
- Issue
- 4
- Pages
- 587-596
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W1977675354
- Cited by
- 38
- References
- 10
- FWCI
- 2.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.