CoChat

A Novel Analytical Method for Assessing Glucose Variability: Using CGMS in Type 1 Diabetes Mellitus

McCall, Anthony L., Cox, Daniel J., Crean, John, Gloster, Maury, Kovatchev, Boris P. · 2006 · Diabetes Technology & Therapeutics
Cited by 73

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Marked blood glucose (BG) fluctuations may increase the risk of some complications associated with diabetes. Acute BG excursions are common in patients with diabetes, but are not usually quantified, nor can they be captured by glycosylated hemoglobin level. This study evaluated the sensitivity of novel analytical methods for assessing BG variability using CGMS (Medtronic Minimed, Northridge, CA) data from patients treated with pramlintide, a drug that acutely reduces postprandial hyperglycemia when added to insulin therapy. METHODS: Retrospective analyses were done on 24-h CGMS profiles obtained from 22 evaluable subjects with type 1 diabetes using insulin pumps and receiving preprandial three times daily injections of placebo (n = 6) or 30 microg of pramlintide (n = 16) for 4 weeks. CGMS data were recorded at baseline, after 4 weeks of treatment, and after 2 weeks off-treatment. Three parameters were calculated for each time period: variability (BG rate of change), an index for severe hypoglycemia [low BG index (LBGI)], and an index for marked hyperglycemia [high BG index (HBGI)]. RESULTS: The mean postprandial BG rate of change was significantly lower after 4 weeks of pramlintide treatment compared with placebo treatment (0.87 vs. 1.21 mg/dL/min, P < 0.01) without changes in average glycemia, illustrating the sensitivity of this parameter to medication effects. The HBGI and LBGI indicated a decreased risk of hyperglycemia without a significant increase in risk of hypoglycemia after 4 weeks of pramlintide. CONCLUSIONS: These results suggest the potential utility of several novel methods for assessing variability and glycemic extremes to gauge the effects of pharmacological interventions not captured by glycosylated hemoglobin.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2006.8.644

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 73

Metadata

Authors
McCall, A. L., Cox, D. J., Crean, J., Gloster, M., & Kovatchev, B. P.
Venue
Diabetes Technology & Therapeutics
Published
2006-12
Volume
8
Issue
6
Pages
644-653
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W1987610957
Cited by
73
References
6
FWCI
3.63
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Novel Analytical Method for Assessing Glucose Variability: Using CGMS in Type 1 Diabetes Mellitus. https://app.cochat.ai/papers/10.1089/dia.2006.8.644
The paper
McCall, A. L., Cox, D. J., Crean, J., Gloster, M., & Kovatchev, B. P. (2006). A Novel Analytical Method for Assessing Glucose Variability: Using CGMS in Type 1 Diabetes Mellitus. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2006.8.644

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.