CoChat

In Silico Preclinical Trials: A Proof of Concept in Closed-Loop Control of Type 1 Diabetes

Open access
Kovatchev, Boris P., Breton, Marc, Dalla Man, Chiara, Cobelli, Claudio · 2009 · Journal of Diabetes Science and Technology

The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.

Abstract

Arguably, a minimally invasive system using subcutaneous (s.c.) continuous glucose monitoring (CGM) and s.c. insulin delivery via insulin pump would be a most feasible step to closed-loop control in type 1 diabetes mellitus (T1DM). Consequently, diabetes technology is focusing on developing an artificial pancreas using control algorithms to link CGM with s.c. insulin delivery. The future development of the artificial pancreas will be greatly accelerated by employing mathematical modeling and computer simulation. Realistic computer simulation is capable of providing invaluable information about the safety and the limitations of closed-loop control algorithms, guiding clinical studies, and out-ruling ineffective control scenarios in a cost-effective manner. Thus computer simulation testing of closed-loop control algorithms is regarded as a prerequisite to clinical trials of the artificial pancreas. In this paper, we present a system for in silico testing of control algorithms that has three principal components: (1) a large cohort of n = 300 simulated “subjects” ( n = 100 adults, 100 adolescents, and 100 children) based on real individuals' data and spanning the observed variability of key metabolic parameters in the general population of people with T1DM; (2) a simulator of CGM sensor errors representative of Freestyle Navigator™, Guardian RT, or Dexcom™ STS™, 7-day sensor; and (3) a simulator of discrete s.c. insulin delivery via OmniPod Insulin Management System or Deltec Cozmo® insulin pump. The system has been shown to represent adequate glucose fluctuations in T1DM observed during meal challenges, and has been accepted by the Food and Drug Administration as a substitute to animal trials in the preclinical testing of closed-loop control strategies.

Overview

Integrity signals

Registry

Crossref · 10.1177/193229680900300106

Cites

49 of 49 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

5 more claims about this paper

Create a free account to see every claim other papers make about this one.

See all claims — free account

Citations

Cites

Show all 49 references

Research works printed but not linked: 4

  1. Clemens AH, 1977, Horm Metab Res., 23
  2. Fischer U, 1978, Endokrinologie., 71, 65
  3. Clemens AH, 1979, Med Prog Technol., 6, 91
  4. Zisser H, Shwartz S, Ratner R, Wise J, Bailey T. Accuracy of a seven-day continuous glucose sensor compared to YSI blood glucose values. Proc 27th Workshop of the AIDPIT Study Group. Innsbruck, Austria. AIDPIT; 2008. p. S03. http://www.aidpit.org.

Cited by

See all 870

Metadata

Authors
Kovatchev, B. P., Breton, M., Dalla Man, C., & Cobelli, C.
Affiliations
  • University of Virginia (US)
  • Department of Information Engineering, University of Padova, Padova, Italy
  • University of Padua (IT)
Corresponding author
Kovatchev, Boris P.
Venue
Journal of Diabetes Science and Technology
Published
2009-01
Volume
3
Issue
1
Pages
44-55
ISSN
1932-2968 (ISSN-L)
OpenAlex
W2167160009
Cited by
760
References
49
Citations by year
2026: 26 · 2025: 23 · 2024: 29 · 2023: 31 · 2022: 30 · 2021: 42 · 2020: 50 · 2019: 55 · 2018: 54 · 2017: 51 · 2016: 48 · 2015: 48 · 2014: 64 · 2013: 66 · 2012: 49
Type
conference abstract
Language
en
Open access
Licence
journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
Locations
  • Journal of Diabetes Science and Technology (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Institutes of Health (5r01dk051562-23)
  • National Institute of Diabetes and Digestive and Kidney Diseases (R01DK 51562, R01-DK-051562)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Pancreatic function and diabetes
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
Keywords
type 1 diabetes, feedback control, artificial pancreas, continuous glucose monitoring, subcutaneous insulin administration, insulin pump, control algorithm simulation, meal challenge, glycemic variability
MeSH terms
Adolescent, Adult, Algorithms, Blood Glucose, Child, Computer Simulation, Diabetes Mellitus, Type 1, Drug Evaluation, Preclinical, Glucose, Humans, Insulin Infusion Systems, Blood Glucose Self-Monitoring

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: In Silico Preclinical Trials: A Proof of Concept in Closed-Loop Control of Type 1 Diabetes. https://app.cochat.ai/papers/10.1177/193229680900300106
The paper
Kovatchev, B. P., Breton, M., Dalla Man, C., & Cobelli, C. (2009). In Silico Preclinical Trials: A Proof of Concept in Closed-Loop Control of Type 1 Diabetes. Journal of Diabetes Science and Technology. https://doi.org/10.1177/193229680900300106

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.