The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Characterizing Glucose Exposure for Individuals with Normal Glucose Tolerance Using Continuous Glucose Monitoring and Ambulatory Glucose Profile Analysis
Abstract
BACKGROUND: Efforts to mimic euglycemia depend upon targets from epidemiologic studies that rely on episodic measurements reduced to statistical summaries, leaving open the question, "What is normal glycemia?" We postulated that portrayal of euglycemia was possible through application of continuous glucose monitoring (CGM) and a novel analytical tool, the ambulatory glucose profile (AGP). METHODS: Individuals with normal glucose tolerance (NGT) and with diabetes used CGM for 30 days. AGP analysis, which graphs CGM data by time without regard to date, was used to characterize glucose exposure, variability, and stability. RESULTS: Sixty-two subjects completed the study, employing CGM for 28 +/- 4 days averaging 99 +/- 18 (range, 33-125) readings per day. NGT subjects (n = 32) had a mean CGM of 102 +/- 7 mg/dL, ranging between 94 and 117 mg/dL and averaging 105 +/- 8 mg/dL daytime and 97 +/- 6 mg/dL overnight. Glucose variability, as expressed by the interquartile range, was 21 +/- 4 mg/dL (range, 14-29 mg/dL). Stability in glycemic control (hourly change in the median) for NGT subjects averaged 3 +/- 1 mg/dL/h. Subjects with diabetes (n = 30) were significantly higher on all glycemic characteristics with the exception of the percentage of hypoglycemic (CGM <70 mg/dL) episodes for type 2 diabetes (2.9%), compared to 2.7% for subjects with NGT. CONCLUSIONS: CGM technologies enabled collection of verified data under normal living conditions, providing an exceptional vantage point from which to obtain important clinical information. This will facilitate an understanding of the range of euglycemic patterns, provide a sensitive means of detecting impaired glucose tolerance, and help set realistic treatment goals for individuals with diabetes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intensive diabetes treatment and cardiovascular disease in patients with type 1 diabetes
(2005) · New England Journal of Medicine · doi:10.1056/nejmoa052187 · Cited by 5,138
Standards of Medical Care in Diabetes—2007
American Diabetes Association (2007) · Diabetes Care · doi:10.2337/dc07-s004 · Cited by 1,190
Cryer, P. E., Davis, S. N., & Shamoon, H. (2003) · Diabetes Care · doi:10.2337/diacare.26.6.1902 · Cited by 1,160
Hypoglycemia in the Diabetes Control and Complications Trial
The Diabetes Control and Complications Trial Research Group (1997) · Diabetes · doi:10.2337/diab.46.2.271 · Cited by 746
Deiss, D., Bolinder, J., Riveline, J.-P., Battelino, T., Bosi, E., Tubiana-Rufi, N., Kerr, D., & Phillip, M. (2006) · Diabetes Care · doi:10.2337/dc06-1134 · Cited by 539
Normal fasting plasma glucose levels and type 2 diabetes in young men
Tirosh, A., Shai, I., Tekes-Manova, D., Israeli, E., Pereg, D., Shochat, T., Kochba, I., & Rudich, A. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa050080 · Cited by 508
Hypoglycaemia in insulin‐treated Type 2 diabetes: frequency, symptoms and impaired awareness
Henderson, J. N., Allen, K. V., Deary, I. J., & Frier, B. M. (2003) · Diabetic Medicine · doi:10.1046/j.1464-5491.2003.01072.x · Cited by 287
Chico, A., Vidal-Ríos, P., Subirà, M., & Novials, A. (2003) · Diabetes Care · doi:10.2337/diacare.26.4.1153 · Cited by 235
Bailey, T. S., Zisser, H. C., & Garg, S. K. (2007) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2007.0205 · Cited by 159
Cited by
Augustin, L. S. A., Kendall, C. W. C., Jenkins, D. J. A., Willett, W. C., Astrup, A., Barclay, A. W., Björck, I., Brand-Miller, J. C., Brighenti, F., Buyken, A. E., et al. (2015) · Nutrition, Metabolism and Cardiovascular Diseases · doi:10.1016/j.numecd.2015.05.005 · Cited by 707
The relationships between time in range, hyperglycemia metrics, and HbA1c
Beck, R. W., Bergenstal, R. M., Cheng, P., Kollman, C., Carlson, A. L., Johnson, M. L., & Rodbard, D. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818822496 · Cited by 479
Self-citationContinuous glucose monitoring: a review of recent studies demonstrating improved glycemic outcomes
Rodbard, D. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0035 · Cited by 458
Agiostratidou, G., Anhalt, H., Ball, D., Blonde, L., Gourgari, E., Harriman, K. N., Kowalski, A. J., Madden, P., McAuliffe-Fogarty, A. H., McElwee-Malloy, M., et al. (2017) · Diabetes Care · doi:10.2337/dc17-1624 · Cited by 397
Hill, N. R., Oliver, N. S., Choudhary, P., Levy, J. C., Hindmarsh, P., & Matthews, D. R. (2011) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2010.0247 · Cited by 362
Metadata
- Authors
- Mazze, R. S., Strock, E., Wesley, D., Borgman, S., Morgan, B., Bergenstal, R., & Cuddihy, R.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2008-06
- Volume
- 10
- Issue
- 3
- Pages
- 149-159
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2083061846
- Cited by
- 182
- References
- 9
- FWCI
- 8.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Characterizing Glucose Exposure for Individuals with Normal Glucose Tolerance Using Continuous Glucose Monitoring and Ambulatory Glucose Profile Analysis. https://app.cochat.ai/papers/10.1089/dia.2007.0293
- The paper
- Mazze, R. S., Strock, E., Wesley, D., Borgman, S., Morgan, B., Bergenstal, R., & Cuddihy, R. (2008). Characterizing Glucose Exposure for Individuals with Normal Glucose Tolerance Using Continuous Glucose Monitoring and Ambulatory Glucose Profile Analysis. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2007.0293
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.