BACKGROUND: Management of type 1 diabetes could be significantly improved with the availability of computerized insulin algorithms for home use. METHODS: This was a 1-year open label randomized control trial involving 123 adult subjects with type 1 diabetes (hemoglobin A1c values 7.5-11%) assigned to either the insulin guidance software (ACCU-CHEK) [Roche, Indianapolis, IN] Advisor) for personal data assistant (experimental group) or the control group. The primary aim of the study was to see if subjects using insulin dosing advisor software will improve glucose control over 1 year. The principal end point was an improvement in A1c at 6 and 12 months by >or=0.4%. RESULTS: Baseline demographics were similar in the two groups. Mean A1c was 8.54+/-0.11% in the control group and 8.42+/-0.11% (P=0.4265) in the experimental group. The mean A1c was significantly lower from 3 to 12 months in the experimental group (P<0.02). A1c reduction of >or=0.6% was maintained at 12 months in the experimental group. Also, a significantly higher number of subjects achieved A1c <7.5% in the experimental group from 3 to 9 months. Within target range glycemia (70-150 mg/dL) was higher in the experimental group at 3-9 months without any change in insulin dose or weight. Above target range glycemia was lower in the experimental group throughout the study. Frequency of testing per day was higher in the experimental group. Nocturnal hypoglycemia was not different between groups; however, the experimental group experienced more severe hypoglycemic events. CONCLUSIONS: This is the first report that shows improved glycemic control can be maintained over 12 months in patients with type 1 diabetes by using Advisor with no change in insulin dose and weight.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2007.0303

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 43

Metadata

Authors
Garg, S. K., Bookout, T. R., McFann, K. K., Kelly, W. C., Beatson, C., Ellis, S. L., Gutin, R. S., & Gottlieb, P. A.
Venue
Diabetes Technology & Therapeutics
Published
2008-10
Volume
10
Issue
5
Pages
369-375
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W2010796291
Cited by
43
References
4
FWCI
1.31
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Improved Glycemic Control in Intensively Treated Adult Subjects with Type 1 Diabetes Using Insulin Guidance Software. https://app.cochat.ai/papers/10.1089/dia.2007.0303
The paper
Garg, S. K., Bookout, T. R., McFann, K. K., Kelly, W. C., Beatson, C., Ellis, S. L., Gutin, R. S., & Gottlieb, P. A. (2008). Improved Glycemic Control in Intensively Treated Adult Subjects with Type 1 Diabetes Using Insulin Guidance Software. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2007.0303

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.