Is an Automatic Pump Suspension Feature Safe for Children with Type 1 Diabetes? An Exploratory Analysis with a Closed-Loop System
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: It has been proposed that the first step towards a closed-loop artificial pancreas might be to use a continuous glucose sensor to automatically suspend the basal insulin delivery based on projected low sensor glucose values. METHODS: We reviewed our recent experience with an artificial pancreas system, utilizing a proportional-integrative-derivative (PID) algorithm, in 17 adolescents with type 1 diabetes (T1D) to assess the safety and efficacy of this maneuver. RESULTS: During 34 h of closed-loop automated insulin delivery, 18 pump suspensions > or =60 min (90 +/- 18 min) occurred in eight subjects. Sensor glucose levels fell from 159 +/- 42 mg/dL to a nadir of 72 +/- 13 mg/dL. Corresponding plasma glucose levels fell from 168 +/- 51 to 72 +/- 16 mg/dL, with values <60 mg/dL recorded in only four of the 18 events. CONCLUSIONS: These data suggest that automatic pump suspension using the PID algorithm may be an effective means to prevent hypoglycemia in youth with T1D.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Attia, N., Jones, T. W., Holcombe, J., & Tamborlane, W. V. (1998) · Diabetes Care · doi:10.2337/diacare.21.5.817 · Cited by 98
Self-citation
Cited by
Flexible Sensing Electronics for Wearable/Attachable Health Monitoring
Wang, X., Liu, Z., & Zhang, T. (2017) · Small · doi:10.1002/smll.201602790 · Cited by 1,075
Diabetes: Models, Signals, and Control
Cobelli, C., Dalla Man, C., Sparacino, G., Magni, L., De Nicolao, G., & Kovatchev, B. P. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2036073 · Cited by 511
“This approach has been shown to reduce the risk of nocturnal hypoglycemia [242], [250].”
Chang, H., Zheng, M., Yu, X., Than, A., Seeni, R. Z., Kang, R., Tian, J., Khanh, D. P., Liu, L., Chen, P., et al. (2017) · Advanced Materials · doi:10.1002/adma.201702243 · Cited by 462
Closed-loop insulin delivery from bench to clinical practice
Hovorka, R. (2011) · Nature Reviews Endocrinology · doi:10.1038/nrendo.2011.32 · Cited by 342
Challenges and recent progress in the development of a closed-loop artificial pancreas
Bequette, B. W. (2012) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2012.09.007 · Cited by 183
“Clarke and Renard (2012) note that the weakest part of the infusion system remains the catheter, while Heinemann and Krinelke (2012) refer to insulin infusion sets as the ‘‘Achilles Heel’’ of continuous subcutaneous insulin infusion.”
BackgroundMethod
Metadata
- Authors
- Cengiz, E., Swan, K. L., Tamborlane, W. V., Steil, G. M., Steffen, A. T., & Weinzimer, S. A.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2009-04
- Volume
- 11
- Issue
- 4
- Pages
- 207-210
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W1991978558
- Cited by
- 64
- References
- 1
- FWCI
- 6.96
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.