Responses to Continuous Glucose Monitoring in Subjects with Type 1 Diabetes Using Continuous Subcutaneous Insulin Infusion or Multiple Daily Injections
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: We compared changes in response to unmasking of continuous glucose monitoring (CGM) in subjects with type 1 diabetes who use multiple daily injections (MDI) or continuous subcutaneous insulin infusion (CSII). RESEARCH DESIGN AND METHODS: Use of real-time CGM (DexCom [San Diego, CA] SEVEN was studied in 38 subjects using CSII and 26 using MDI. CGM output was masked during Week 1 and unmasked during Weeks 2 and 3. We evaluated changes in 16 criteria for quality of glycemic control and eight criteria for glycemic variability. RESULTS: All 24 criteria showed highly statistically significant improvement when considered simultaneously (P < 0.000001). For subjects using CSII, 18 of 24 criteria improved significantly (nominal P < 0.05); for subjects using MDI, 16 of 24 criteria improved significantly (P < 0.05). Twelve of the comparisons remained significant (P < 0.05) after applying the overconservative Bonferroni correction for multiple comparisons. The percentage of glucose values within the range 80-140 mg/dL increased by 19% and 17% relative to their control values (Week 1) for subjects using MDI and CSII, respectively. Mean glucose, overall SD (SD(T)), SD between daily means (SD(dm)), mean amplitude of glycemic excursion (MAGE), and mean of daily differences (MODD) improved significantly. Responses to CGM display were not significantly different between the MDI and CSII subject groups for any of the 24 criteria considered individually or in groups of eight, 16, or 24. CONCLUSION: CGM has similar effectiveness in subjects with type 1 diabetes using either CSII or MDI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
Ceriello, A., Esposito, K., Piconi, L., Ihnat, M. A., Thorpe, J. E., Testa, R., Boemi, M., & Giugliano, D. (2008) · Diabetes · doi:10.2337/db08-0063 · Cited by 1,310
Deiss, D., Bolinder, J., Riveline, J.-P., Battelino, T., Bosi, E., Tubiana-Rufi, N., Kerr, D., & Phillip, M. (2006) · Diabetes Care · doi:10.2337/dc06-1134 · Cited by 539
The effect of continuous glucose monitoring in well-controlled type 1 diabetes
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2009) · Diabetes Care · doi:10.2337/dc09-0108 · Cited by 399
Bailey, T. S., Zisser, H. C., & Garg, S. K. (2007) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2007.0205 · Cited by 159
Self-citation
Cited by
Šoupal, J., Petruželková, L., Flekač, M., Pelcl, T., Matoulek, M., Daňková, M., Škrha, J., Svačina, Š., & Prázný, M. (2016) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0171 · Cited by 126
Garg, S. K., Voelmle, M. K., Beatson, C. R., Miller, H. A., Crew, L. B., Freson, B. J., & Hazenfield, R. M. (2011) · Diabetes Care · doi:10.2337/dc10-1852 · Cited by 85
Self-citationRodbard, D. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0440 · Cited by 75
Self-citationImproved Real-World Glycemic Control With Continuous Glucose Monitoring System Predictive Alerts
Abraham, S. B., Arunachalam, S., Zhong, A., Agrawal, P., Cohen, O., & McMahon, C. M. (2021) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819859334 · Cited by 63
Metadata
- Authors
- Rodbard, D., Jovanovic, L., & Garg, S. K.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2009-12
- Volume
- 11
- Issue
- 12
- Pages
- 757-765
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W1995339883
- Cited by
- 32
- References
- 5
- FWCI
- 3.04
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.