Quality of Glucose Measurement with Blood Glucose Meters at the Point-of-Care: Relevance of Interfering Factors
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
AIM: A good understanding of the relevance of interfering factors having an impact on blood glucose (BG) measurement is needed to obtain the required quality. This depends on the application in which meters designed for self-monitoring of BG (SMBG) are used. METHODS: By means of a literature search all publications (from January 1, 1980 to August 10, 2009) were identified that report about the influence of potentially interfering substances/factors on the measurement quality of BG meters. RESULTS: Certain substances (e.g., maltose) can have a profound and misleading impact on the BG measurement result when the enzymatic reaction embedded on the given test strips cross-reacts. Also, a number of other drugs (e.g., acetaminophen) and factors (like temperature and altitude) affect the reliability of BG measurement massively. However, the susceptibility of the BG meter (depending on the enzyme technology of the test strips) differs significantly. CONCLUSIONS: In daily practice the factors that have a relevant impact on the reliability of BG measurements with modern BG meters are rarely met. Clearly this also depends on the intended use (SMBG in patient hands vs. point-of-care testing in hospitals). To avoid misleading measurement results requires adequate training of all people involved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
System Accuracy Evaluation of 27 Blood Glucose Monitoring Systems According to DIN EN ISO 15197
Freckmann, G., Baumstark, A., Jendrike, N., Zschornack, E., Kocher, S., Tshiananga, J., Heister, F., & Haug, C. (2010) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0128 · Cited by 195
Overview on self-monitoring of blood glucose
Montagnana, M., Caputo, M., Giavarina, D., & Lippi, G. (2009) · Clinica Chimica Acta · doi:10.1016/j.cca.2009.01.002 · Cited by 116 · cited 2×
“…33 2001 Maltose (icodextrin) Michel et al. 34 2005 Hematocrit Moatti-Sirat et al. 35 1994 Acetaminophen Moberly et al. 36 2002 Maltose (icodextrin) Montagnana et al. 37 2009 Hematocrit, maltose, galactose, xylose, acetaminophen Nawawi et al. 38 2001 Hematocrit, maltose, galactose, xylose,…”
Interference of Maltose, Icodextrin, Galactose, or Xylose with Some Blood Glucose Monitoring Systems
Schleis, T. G. (2007) · Pharmacotherapy: The Journal of Human Pharmacology and Drug Therapy · doi:10.1592/phco.27.9.1313 · Cited by 102
Frias, J. P., Lim, C. G., Ellison, J. M., & Montandon, C. M. (2010) · Diabetes Care · doi:10.2337/dc09-1822 · Cited by 73
Cited by
Investigation of the Accuracy of 18 Marketed Blood Glucose Monitors
Klonoff, D. C., Parkes, J. L., Kovatchev, B. P., Kerr, D., Bevier, W. C., Brazg, R. L., Christiansen, M., Bailey, T. S., Nichols, J. H., & Kohn, M. A. (2018) · Diabetes Care · doi:10.2337/dc17-1960 · Cited by 144
Interferences and Limitations in Blood Glucose Self-Testing: An Overview of the Current Knowledge
Erbach, M., Freckmann, G., Hinzmann, R., Kulzer, B., Ziegler, R., Heinemann, L., & Schnell, O. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816641433 · Cited by 115
Self-citationInterferences with CGM systems: practical relevance?
Heinemann, L. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/19322968211065065 · Cited by 65
Self-citationCeriotti, F., Kaczmarek, E., Guerra, E., Mastrantonio, F., Lucarelli, F., Valgimigli, F., & Mosca, A. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814563351 · Cited by 45
“However, it has been well reported that the accuracy of many hospital glucose meters can be affected by the biochemical and physiological changes that commonly occur in acute, chronic, and critically ill hospital patients and also by the medication prescribed.(11,12) A wide range of endogenous and exogenous substances…”
BackgroundHematocrit compensation in electrochemical blood glucose monitoring systems
Teodorczyk, M., Cardosi, M., & Setford, S. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600320 · Cited by 33
MacRury, S., Srinivasan, A., & Mahoney, J. J. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700215 · Cited by 7
Metadata
- Authors
- Heinemann, L.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2010-11
- Volume
- 12
- Issue
- 11
- Pages
- 847-857
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2014536301
- Cited by
- 62
- References
- 4
- FWCI
- 2.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.