Hematocrit Compensation in Electrochemical Blood Glucose Monitoring Systems

Open access
Teodorczyk, Maria, Cardosi, Marco, Setford, Steven · 2012 · Journal of Diabetes Science and Technology

The DOI matches its Crossref record; 38 of the 39 references it cites were found in a registry or an index.

Abstract

Background: Hematocrit (Hct) is a common interferent in test strips used by diabetes patients to self-monitor blood glucose (BG), resulting in measurement bias. Described is an electrochemical BG monitoring system (OneTouch® Verio™) that uses a cofacial sensor design, soluble enzyme chemistry, and multiphasic waveform to effectively correct for patient Hct, delivering an accurate reading for whole BG. Methods: The test strip comprises thin-film gold and palladium electrodes arranged cofacially and spatially separated with a thin spacer. Soluble glucose-sensing reagents are located on the lower palladium electrode and are hydrated on sample application. Blood glucose is oxidized by flavoprotein glucose dehydrogenase, with electron transfer via (reduced) potassium ferrocyanide mediator at the palladium electrode. Hematocrit levels are estimated by measuring oxidation of mediator diffusion to the upper gold electrode during the first portion of the assay. The Hct-corrected glucose levels are determined by an on-meter algorithm. Results: In performance testing of blood samples at five glucose levels (30–560 mg/dl) and five Hct levels (19–61%), using 12 test meters and 3 test strip lots, 100% of results ( N = 2700) met International Organization for Standardization accuracy criteria (within ± 15 mg/dl and ± 20% of reference results at glucose levels of <75 and ≥75 mg/dl, respectively). Furthermore, 99.9% (2698 of 2700) of results were within ±12 mg/dl and ± 15% of reference values at glucose levels <80 and ≥80 mg/dl, respectively. Conclusions: The technology used in this system provides accurate BG measurements that are insensitive to Hct levels across the range 20–60%.

Overview

Integrity signals

Registry

Crossref · 10.1177/193229681200600320

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 38 references

Research works printed but not linked: 1

  1. Lyon ME, 2011, Biochem., 44, 412

Cited by

See all 33

Metadata

Authors
Teodorczyk, M., Cardosi, M., & Setford, S.
Affiliations
  • Research and Development, LifeScan Inc., Milpitas, California
  • LifeScan Scotland Ltd., Inverness, United Kingdom
Corresponding author
Teodorczyk, Maria
Venue
Journal of Diabetes Science and Technology
Published
2012-05
Volume
6
Issue
3
Pages
648-655
ISSN
1932-2968 (ISSN-L)
OpenAlex
W2141602487
Cited by
33
References
39
Citations by year
2026: 1 · 2025: 3 · 2023: 4 · 2022: 2 · 2021: 3 · 2020: 2 · 2019: 2 · 2018: 4 · 2017: 1 · 2016: 2 · 2015: 2 · 2014: 2 · 2013: 2 · 2012: 3
FWCI
1.84
Type
journal article
Language
en
Open access
Licence
journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
Locations
  • Journal of Diabetes Science and Technology (publishedVersion)
  • Europe PMC (PubMed Central) (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
Keywords
blood glucose monitoring, diabetes self-monitoring, electrochemical glucose sensor, palladium electrodes, gold electrode, glucose dehydrogenase, measurement bias
MeSH terms
Algorithms, Blood Glucose, Electrodes, Equipment Design, Gold, Hematocrit, Humans, Materials Testing, Oxidation-Reduction, Palladium, Predictive Value of Tests, Reagent Strips, Signal Processing, Computer-Assisted, Blood Glucose Self-Monitoring, Reproducibility of Results, Biomarkers, Glucose 1-Dehydrogenase, Electrochemical Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Hematocrit Compensation in Electrochemical Blood Glucose Monitoring Systems. https://app.cochat.ai/papers/10.1177/193229681200600320
The paper
Teodorczyk, M., Cardosi, M., & Setford, S. (2012). Hematocrit Compensation in Electrochemical Blood Glucose Monitoring Systems. Journal of Diabetes Science and Technology. https://doi.org/10.1177/193229681200600320

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.