The DOI matches its Crossref record; 11 of the 12 references it cites were found in a registry or an index.
Optimal Sampling Intervals to Assess Long-Term Glycemic Control Using Continuous Glucose Monitoring
Open accessAbstract
AIMS AND HYPOTHESIS: The optimal duration and frequency of short-term continuous glucose monitoring (CGM) to reflect long-term glycemia have not been determined. The Juvenile Diabetes Research Foundation CGM randomized trials provided a large dataset of longitudinal CGM data for this type of analysis. METHODS: The analysis included 185 subjects who had 334 3-month intervals of CGM data meeting specific criteria. For various glucose indices, correlations (r²) were computed for the entire 3-month interval versus selected sampling periods ranging from 3 to 15 days. Other computed agreement measures included median relative absolute difference, values within ± 10% and ± 20% of full value, and median absolute difference. RESULTS: As would be expected, the more days of glucose data that were sampled, the higher the correlation with the full 3 months of data. For 3 days of sampling, the r² value ranged from 0.32 to 0.47, evaluating mean glucose, percentage of values 71-180 mg/dL, percentage of values > 180 mg/dL, percentage of values ≤ 70 mg/dL, and coefficient of variation; in contrast, for 15 days of sampling, the r² values ranged from 0.66 to 0.75. The results were similar when the analysis intervals were stratified by age group (8-14, 15-24, and ≥ 25 years), by baseline hemoglobin A1c level (< 7.0% and ≥ 7.0%), and by CGM device type. CONCLUSIONS AND INTERPRETATION: Our data suggest that a 12-15-day period of monitoring every 3 months may be needed to optimally assess overall glucose control. Shorter periods of sampling can be useful, but the correlation with 3-month measures of glycemic control is lower.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“In individuals with type 1 diabetes, correlations are weaker for hypoglycemia and glycemic variability; however, these correlations have not been shown to increase with longer sampling periods (42).”
From Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in Range (2019) · cites this paper as [42]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredThe cited source doesn’t support the claim as written.
In the citing paper
“In individuals with type 1 diabetes, correlations are weaker for hypoglycemia and glycemic variability; however, these correlations have not been shown to increase with longer sampling periods (42).”
From Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in Range (2019) · cites this paper as [42]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Translating the A1C assay into estimated average glucose values
Nathan, D. M., Kuenen, J., Borg, R., Zheng, H., Schoenfeld, D., Heine, R. J., & for the A1c-Derived Average Glucose (ADAG) Study Group (2008) · Diabetes Care · doi:10.2337/dc08-0545 · Cited by 1,812
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
The effect of continuous glucose monitoring in well-controlled type 1 diabetes
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2009) · Diabetes Care · doi:10.2337/dc09-0108 · Cited by 399
Effectiveness of Continuous Glucose Monitoring in a Clinical Care Environment
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2010) · Diabetes Care · doi:10.2337/dc09-1502 · Cited by 313
Bode, B. W., Gross, K. M., Rikalo, N., Schwartz, S. L., Wahl, T. O., Page, C. W., Gross, T. M., & Mastrototaro, J. J. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/152091504773731285 · Cited by 190
Chase, H. P., Beck, R. W., Xing, D., Tamborlane, W. V., Coffey, J., Fox, L. A., Ives, B., Keady, J., Kollman, C., Laffel, L. M., et al. (2010) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2010.0021 · Cited by 142
Wilson, D. M., Beck, R. W., Tamborlane, W. V., Dontchev, M., Kollman, C., Chase, P., Fox, L. A., Ruedy, K. J., Tsalikian, E., WEINZIMER, S. A., et al. (2006) · Diabetes Care · doi:10.2337/dc06-1407 · Cited by 134
The Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2009) · Diabetes Care · doi:10.2337/dc09-0846 · Cited by 121
JDRF CGM Study Group (2008) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2007.0302 · Cited by 115
The Diabetes Research in Children Network (DirecNet) Study Group (2005) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2004-2510 · Cited by 88
Flagged first, then by citations
1 of the 12 references couldn’t be matched to a known paper.
Research works printed but not linked: 3
- Bugler J. An estimation of the amount of data required to measure glycemic variability. Presented at the Advanced Technologies and Treatment for Diabetes Conference, Prague, Czech Republic, 2008.
- DexCom Inc. DexCom™ STS™ Continuous Glucose Monitoring System User's Guide. San Diego, CA: DexCom Inc., 2006; 86–102.
- Magee L. R2 measures based on Wald and Likelihood Ratio Joint Significance tests. Am Stat, 1990; 44:250–253.
Cited by
Sorted by citations
Items 101–131 of 131
Early Glycemic Control Assessment Based on Consensus CGM Metrics
Mohebbi, A., Bohm, A.-K., Tarp, J. M., Jensen, M. L., Bengtsson, H., & Mørup, M. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9631015 · Cited by 3
Sifri, S. A., Alshaikh, A., Bin-Abbas, B. S., Sheshah, E., Sabaan, F. S. A., Aldawish, M., Al-Dubayee, M., Alzaman, N. S., Aldahash, R., ALZAHRANI, S. H., et al. (2021) · International Journal of Clinical Medicine · doi:10.4236/ijcm.2021.128028 · Cited by 3
Maines, E., Pertile, R., Cauvin, V., Soffiati, M., & Franceschi, R. (2024) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2024.111720 · Cited by 2
Terayama, M., Imamura, Y., Kitazawa, T., Miyazaki, N., Ishii, M., Takagi, K., Kuriyama, K., Takahashi, N., Tamura, M., Okamura, A., et al. (2025) · PLoS ONE · doi:10.1371/journal.pone.0325039 · Cited by 2
Jalaludin, M. Y., Pérez, M. B., Hafez, M., Lynch, J. L., Shehadeh, N., Turan, S., & Weghuber, D. (2019) · Clinical Trials · doi:10.1177/1740774519870190 · Cited by 2
Pepper, G. M. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2012.0216 · Cited by 2
Mazze, R. S. (2019) · Springer eBooks · doi:10.1007/978-3-030-11815-0_28 · Cited by 2
Grain found growing in the eye.
Sil, A. K. (2000) · PubMed Central · Cited by 2
The Relationship Between Glycated Hemoglobin and Time in Range in a Pediatric Population
Vandenbempt, M., Matheussen, H., Charleer, S., Rochtus, A. M., & Casteels, K. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0482 · Cited by 2
Continuous glucose monitoring in 2011
Battelino, T., & Bode, B. W. (2012) · International Journal of Clinical Practice · doi:10.1111/j.1742-1241.2011.02848.x · Cited by 1
¿De qué nos sirve evaluar las tendencias del perfil glucémico ambulatorio?
Izquierdo, E. S. (2014) · Avances en Diabetología · doi:10.1016/j.avdiab.2014.06.002 · Cited by 1
Interpretación del monitoreo continuo de glucosa: una visión práctica
Coronel-Restrepo, N., Rincón, A. R., Palacio, A., Delgado, M. R., & Botero, J. F. (2023) · Revista Colombiana de Endocrinología Diabetes & Metabolismo · doi:10.53853/encr.10.1.764 · Cited by 1
Oraibi, O., Somaili, M., Elmakki, E. E., Alqassimi, S., Madkhali, M. A., Mohrag, M., Abusageah, F., Alhazmi, M. K., Alfaifi, S. M., Ageeli, R., et al. (2023) · Endocrine Metabolic & Immune Disorders - Drug Targets · doi:10.2174/0118715303263019231029163336 · Cited by 1
Continuous glucose monitoring metrics in pregnancy with type 1 diabetes mellitus
Jeeyavudeen, M. S., Crosby, M., & Pappachan, J. M. (2024) · World Journal of Methodology · doi:10.5662/wjm.v14.i1.90316 · Cited by 3
Continuous Glucose Monitoring in Individuals With Type 2 Diabetes: A Quality Improvement Program
Kinson, L., & Inman, K. (2024) · Clinical Diabetes · doi:10.2337/cd24-0006 · Cited by 3
Sebastián‐Valles, F., Martín, J. A. A., Alfonso, J. M., Jiménez‐Díaz, J., Alday, I. H., Navas-Moreno, V., Joya, T. A., García, M., Gómez, G. L. R., Hierro, J. G., et al. (2024) · Endocrinology Diabetes & Metabolism · doi:10.1002/edm2.70020 · Cited by 1
Gera, S., Rearson, A., Gallop, R., & Marks, B. E. (2025) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2025.0173 · Cited by 1
Does HbA1c Remain the Most Important Therapeutic Target in Outpatient Management of Diabetes?
Gonzales, K. M., & Smith, S. (2021) · Wiley eBooks · doi:10.1002/9781119603207.ch8
Mudit, Palukuri, S., & Deka, S. (2022) · British journal of healthcare and medical research · doi:10.14738/jbemi.91.11756
Mazze, R. S., & Rodríguez‐Saldaña, J. (2023) · Springer eBooks · doi:10.1007/978-3-031-25519-9_30
Yamada, E., Nakajima, Y., Horiguchi, K., Okada, S., & Yamada, M. (2023) · Endocrine Journal · doi:10.1507/endocrj.ej23-0125
Csermely, A., Borella, N. D., Turazzini, A., Pilati, M., Sheiban, S. S., Bonadonna, R. C., Trevisan, R., Trombetta, M., & Lepore, G. (2025) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241308564
Zoet, S., Urgert, T., Veldhuis, A., van Beijnum, B.-J. F., & Laverman, G. D. (2025) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2024-004768 · Cited by 1
Mizokami‐Stout, K., Voelker, K., DeJonckheere, M. J., Ang, L. P., Reynolds, E. L., Lee, J. M., Pop‐Busui, R., Callaghan, B. C., Hirschfeld, E., Iyengar, J. J., et al. (2026) · JMIR Diabetes · doi:10.2196/87688
Bibby, B. M., Bach, E., Christensen, M., Fisker, S., & Hansen, K. W. (2026) · Diabetic Medicine · doi:10.1111/dme.70272
Pazos-Couselo, M., Izquierdo, V., Martínez, M. M., Romero, F. J. G., Muñoz‐Rodríguez, J. R., Fernández‐Pombo, A., & Moreno-Fernández, J. (2026) · Worldviews on Evidence-Based Nursing · doi:10.1111/wvn.70139
Sánchez-Arlegui, A., Muñoz‐Pardeza, J., Hormazábal‐Aguayo, I., Abio-Abero, S., Bertholt-Zuber, M. L., Alonso-Rubio, P., Sánchez, E. B., Chueca-Guindulain, M. J., Zamalloa, C. C., Congost-Marín, S., et al. (2026) · Frontiers in Endocrinology · doi:10.3389/fendo.2026.1913568
Sensors in Digital Health Solutions Empowered by Artificial Intelligence Capabilities
Hetemi, D., Pinson, J., Noël, V., Shkirskiy, V., & Hoti, K. (2026) · IEEE Sensors Reviews · doi:10.1109/sr.2026.3722596
Interpretation of CGM and Insulin Pump Downloads
McDonnell, D. J., Smith, D., & Forde, H. E. (2026) · Springer eBooks · doi:10.1007/978-3-032-24854-1_7
Three-Year Real-World Performance of Bihormonal Fully Closed-Loop Therapy in Type 1 Diabetes
Jansen, T. J. P., den Drijver, C., Vlaskamp, L. B., & van Bon, A. C. (2026) · Diabetes Technology & Therapeutics · doi:10.1177/15209156261492793
Aktürk, H. K., Karakus, K. E., Mason, E., Yilmaz, Z. Y., Garg, S. K., & Cengiz, D. (2026) · Diabetes Technology & Therapeutics · doi:10.1177/15209156261496613
Metadata
- Authors
- Xing, D., Kollman, C., Beck, R. W., Tamborlane, W. V., Laffel, L., Buckingham, B. A., Wilson, D. M., Weinzimer, S., Fiallo-Scharer, R., & Ruedy for the Juvenile Diabetes Research Foundation Continuo, K. J.
- Affiliations
- Jaeb Center for Health Research (US)
- Yale University (US)
- Joslin Diabetes Center (US)
- Stanford University (US)
- Barbara Davis Center
- Jaeb Center for Health Research
- Corresponding author
- Xing, Dongyuan
- ORCID
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2011-03
- Volume
- 13
- Issue
- 3
- Pages
- 351-358
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- PMC
- PMC6468940
- OpenAlex
- W2007986610
- Cited by
- 131
- References
- 12
- Citations by year
- 2026: 10 · 2025: 7 · 2024: 11 · 2023: 15 · 2022: 18 · 2021: 21 · 2020: 15 · 2019: 10 · 2018: 4 · 2017: 6 · 2016: 4 · 2015: 1 · 2014: 1 · 2013: 1 · 2012: 5
- FWCI
- 2.10
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Diabetes Technology & Therapeutics (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Eunice Kennedy Shriver National Institute of Child Health and Human Development (U10HD041908)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- continuous glucose monitoring, glycemic control, sampling interval, HbA1c, mean blood glucose, hypoglycemia, hyperglycemia, coefficient of variation, type 1 diabetes
- MeSH terms
- Adolescent, Adult, Aged, Blood Glucose, Child, Diabetes Mellitus, Type 1, Female, Glycated Hemoglobin, Humans, Longitudinal Studies, Male, Middle Aged, Time Factors, Blood Glucose Self-Monitoring, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review