Metabolic Improvements in Obese Type 2 Diabetes Subjects Implanted for 1 Year with an Endoscopically Deployed Duodenal–Jejunal Bypass Liner
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The purpose of this study was to evaluate the effect of the duodenal-jejunal bypass liner (DJBL), a 60-cm, impermeable fluoropolymer liner anchored in the duodenum to create a duodenal-jejunal bypass, on metabolic parameters in obese subjects with type 2 diabetes. METHODS: Twenty-two subjects (mean age, 46.2±10.5 years) with type 2 diabetes and a body mass index between 40 and 60 kg/m(2) (mean body mass index, 44.8±7.4 kg/m(2)) were enrolled in this 52-week, prospective, open-label clinical trial. Endoscopic device implantation was performed with the patient under general anesthesia, and the subjects were examined periodically during the next 52 weeks. Primary end points included changes in fasting blood glucose and insulin levels and changes in hemoglobin A1c (HbA1c). The DJBL was removed endoscopically at the end of the study. RESULTS: Thirteen subjects completed the 52-week study, and the mean duration of the implant period for all subjects was 41.9±3.2 weeks. Reasons for early removal of the device included device migration (n=3), gastrointestinal bleeding (n=1), abdominal pain (n=2), principal investigator request (n=2), and discovery of an unrelated malignancy (n=1). Using last observation carried forward, statistically significant reductions in fasting blood glucose (-30.3±10.2 mg/dL), fasting insulin (-7.3±2.6 μU/mL), and HbA1c (-2.1±0.3%) were observed. At the end of the study, 16 of the 22 subjects had an HbA1c<7% compared with only one of 22 at baseline. Upper abdominal pain (n=11), back pain (n=5), nausea (n=7), and vomiting (n=7) were the most common device-related adverse events. CONCLUSIONS: The DJBL improves glycemic status in obese subjects with diabetes and therefore represents a nonsurgical, reversible alternative to bariatric surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nathan, D. M., Buse, J. B., Davidson, M. B., Ferrannini, E., Holman, R. R., Sherwin, R., & Zinman, B. (2009) · Diabetes Care · doi:10.2337/dc08-9025 · Cited by 3,834
Nguyen, N. T., Nguyen, X.-M. T., Lane, J., & Wang, P. (2011) · Obesity Surgery · doi:10.1007/s11695-010-0335-4 · Cited by 385
Cited by
Abu Dayyeh, B. K., Kumar, N., Edmundowicz, S. A., Jonnalagadda, S., Larsen, M., Sullivan, S., Thompson, C. C., & Banerjee, S. (2015) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2015.03.1964 · Cited by 469
Bariatric surgery and diabetes remission: Who would have thought it?
Singh, A., Singh, R., & Kota, S. (2015) · Indian Journal of Endocrinology and Metabolism · doi:10.4103/2230-8210.163113 · Cited by 48
Effect of the EndoBarrier Device: a 4-Year Follow-up of a Multicenter Randomized Clinical Trial
van Rijn, S., Roebroek, Y. G. M., de Jonge, C., Greve, J. W. M., & Bouvy, N. D. (2019) · Obesity Surgery · doi:10.1007/s11695-018-03659-6 · Cited by 27
Riedel, N., Laubner, K., Lautenbach, A., Schön, G., Schlensak, M., Stengel, R., Eberl, T., Dederichs, F., Aberle, J., & Seufert, J. (2018) · Surgery for Obesity and Related Diseases · doi:10.1016/j.soard.2018.02.029 · Cited by 15
Metadata
- Authors
- de Moura, E. G. H., Martins, B. C., Lopes, G. S., Orso, I. R., de Oliveira, S. L., Galvão Neto, M. P., Santo, M. A., Sakai, P., Ramos, A. C., Garrido Júnior, A. B., Mancini, M. C., Halpern, A., & Cecconello, I.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2012-02
- Volume
- 14
- Issue
- 2
- Pages
- 183-189
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2070776550
- Cited by
- 124
- References
- 3
- FWCI
- 14.16
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.