Effects of Sensor-Augmented Pump Therapy on Glycemic Variability in Well-Controlled Type 1 Diabetes in the STAR 3 Study
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Compared with multiple daily injections (MDI), sensor-augmented pump (SAP) insulin therapy may reduce glycemic variability and oxidative stress in type 1 diabetes in a glycosylated hemoglobin (A1C)-independent manner. SUBJECTS AND METHODS: The STAR 3 study compared SAP with MDI therapy for 1 year. Week-long continuous glucose monitoring studies were conducted at baseline and 1 year for assessment of glycemic variability in both groups. Soluble CD40 ligand (CD40L), a biomarker of inflammation and thrombocyte function, was measured at baseline and 1 year. Subjects were classified according to treatment group and 1-year A1C levels (<6.5%, 6.5-6.9%, 7-7.9%, ≥8%). Glycemic parameters were compared between SAP and MDI subjects in each A1C cohort. RESULTS: At 1 year, sensor glucose values at A1C levels ≥6.5% were similar in the SAP and MDI groups. However, sensor glucose SD and coefficient of variation (CV) values were lower at A1C levels <8% among SAP than among MDI subjects; the overall between-group difference was significant for both SD (P<0.01) and CV (P=0.01). The overall mean amplitude of glycemic excursion was similar in MDI and SAP groups (P=0.23). CD40L levels fell over the course of the study in both groups, but the between-group difference was not significant (P=0.18). CD40L concentrations were unrelated to A1C, change in A1C from baseline, or glycemic variability. CONCLUSIONS: At comparable A1C levels of <8%, SAP reduced glycemic variability as measured by SD and CV compared with MDI. SAP may provide beneficial reductions in the number and severity of glycemic excursions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes
Bergenstal, R. M., Tamborlane, W. V., Ahmann, A., Buse, J. B., Dailey, G., Davis, S. N., Joyce, C., Peoples, T., Perkins, B. A., Welsh, J. B., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1002853 · Cited by 894
Glycemic Variability: A Hemoglobin A1c–Independent Risk Factor for Diabetic Complications
Brownlee, M., & Hirsch, I. B. (2006) · JAMA · doi:10.1001/jama.295.14.1707 · Cited by 482
Effects of Acute Insulin-Induced Hypoglycemia on Indices of Inflammation
Wright, R. J., Newby, D. E., Stirling, D., Ludlam, C. A., Macdonald, I. A., & Frier, B. M. (2010) · Diabetes Care · doi:10.2337/dc10-0013 · Cited by 208
Sensor-Augmented Pump Therapy for A1C Reduction (STAR 3) Study
Bergenstal, R. M., Tamborlane, W. V., Ahmann, A., Buse, J. B., Dailey, G., Davis, S. N., Joyce, C., Perkins, B. A., Welsh, J. B., Willi, S. M., et al. (2011) · Diabetes Care · doi:10.2337/dc11-1248 · Cited by 118
Self-citation
Cited by
Blonde, L., Umpierrez, G. E., Reddy, S. S., McGill, J. B., Berga, S. L., Bush, M., Chandrasekaran, S., DeFronzo, R. A., Einhorn, D., Galindo, R. J., et al. (2022) · Endocrine Practice · doi:10.1016/j.eprac.2022.08.002 · Cited by 507
ISPAD Clinical Practice Consensus Guidelines 2018: diabetes technologies
Sherr, J. L., Tauschmann, M., Battelino, T., de Bock, M., Forlenza, G., Roman, R., Hood, K. K., & Maahs, D. M. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12731 · Cited by 197
Self-citationISPAD Clinical Practice Consensus Guidelines 2022: Diabetes technologies: Insulin delivery
Sherr, J. L., Schoelwer, M., Dos Santos, T. J., Reddy, L., Biester, T., Galderisi, A., van Dyk, J. C., Hilliard, M. E., Berget, C., & DiMeglio, L. A. (2022) · Pediatric Diabetes · doi:10.1111/pedi.13421 · Cited by 152
Livingstone, R., Boyle, J. G., & Petrie, J. R. (2020) · Diabetic Medicine · doi:10.1111/dme.13911 · Cited by 34
Rosenlund, S., Hansen, T. W., Rossing, P., & Andersen, S. (2015) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2015-2839 · Cited by 19
“2015-2839 J Clin Endocrinol Metab, November 2015, 100(11):4181–4188 press.”
BackgroundInfluential
Metadata
- Authors
- Buse, J. B., Kudva, Y. C., Battelino, T., Davis, S. N., Shin, J., & Welsh, J. B.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2012-07
- Volume
- 14
- Issue
- 7
- Pages
- 644-647
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2066309841
- Cited by
- 41
- References
- 4
- FWCI
- 2.07
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effects of Sensor-Augmented Pump Therapy on Glycemic Variability in Well-Controlled Type 1 Diabetes in the STAR 3 Study. https://app.cochat.ai/papers/10.1089/dia.2011.0294
- The paper
- Buse, J. B., Kudva, Y. C., Battelino, T., Davis, S. N., Shin, J., & Welsh, J. B. (2012). Effects of Sensor-Augmented Pump Therapy on Glycemic Variability in Well-Controlled Type 1 Diabetes in the STAR 3 Study. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2011.0294
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.