Use of a “Fuzzy Logic” Controller in a Closed-Loop Artificial Pancreas
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Most current model-based approaches to closed-loop artificial pancreas systems rely on mathematical equations describing the human glucoregulatory system; however, incorporating the various physiological parameters (e.g., illness, stress) into these models has been problematic. We evaluated a fully automated "fuzzy logic" (FL) closed-loop insulin dosing controller that does not require differential equations of the glucoregulatory system and allows clinicians to personalize dosing aggressiveness to meet individual patient requirements. SUBJECTS AND METHODS: This pilot study evaluated the FL controller in the setting of bed rest in a very controlled environment. Two carbohydrate-controlled meals were given (30 g at 8 a.m. and 60 g at 2 p.m. without meal announcement or premeal bolus. The primary end point of the study was avoidance of hypoglycemia, defined at <60 mg/dL. Multiple end points related to the frequency and severity of hyperglycemia and hypoglycemia were also assessed. RESULTS: Of the 12 subjects we recruited, 10 were enrolled, and seven completed the study. Two of the enrolled subjects were discontinued because of hypoglycemia; the other was discontinued because of sensor failure. Seven of the 10 subjects who completed the study had average blood glucose values of 165 mg/dL and were within a specified target blood glucose range (70-200 mg/dL) for 76% of the 24-h study period. CONCLUSIONS: Our findings suggest that the FL controller provides a viable alternative to model-based controllers as a component of a closed-loop insulin delivery system. Furthermore, our FL controller allows clinicians to easily specify the level of glucose control based on each patient's clinical needs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hovorka, R., Kumareswaran, K., Harris, J., Allen, J. M., Elleri, D., Xing, D., Kollman, C., Nodale, M., Murphy, H. R., Dunger, D. B., et al. (2011) · BMJ · doi:10.1136/bmj.d1855 · Cited by 244 · cited 1×
“…in sedentary subjects in clinical research settings, using only the subject’s total daily insulin and CGM data, and that it is comparable to other current closed-loop insulin delivery controllers that use proportional-integral-derivative control 3,4 and model predictive control 5–7 technologies.”
Kovatchev, B., Cobelli, C., Renard, E., Anderson, S., Breton, M., Patek, S., Clarke, W., Bruttomesso, D., Maran, A., Costa, S., et al. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400611 · Cited by 200
Swan, K. L., Dziura, J. D., Steil, G. M., Voskanyan, G. R., Sikes, K. A., Steffen, A. T., Martin, M. L., Tamborlane, W. V., & Weinzimer, S. A. (2009) · Diabetes Care · doi:10.2337/dc08-0595 · Cited by 82
Cited by
Artificial intelligence for diabetes management and decision support: Literature review
Contreras, I., & Vehi, J. (2018) · Journal of Medical Internet Research · doi:10.2196/10775 · Cited by 560
“Next, to demonstrate the feasibility of their approach, they conducted a pilot study in 12 T1D patients [18].”
Closed-Loop Artificial Pancreas Systems: Engineering the Algorithms
Doyle, F. J., Huyett, L. M., Lee, J. B., Zisser, H. C., & Dassau, E. (2014) · Diabetes Care · doi:10.2337/dc13-2108 · Cited by 394
The artificial pancreas: current status and future prospects in the management of diabetes
Peyser, T., Dassau, E., Breton, M., & Skyler, J. S. (2014) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.12431 · Cited by 169
Gondhalekar, R., Dassau, E., & Doyle, F. J. (2016) · Automatica · doi:10.1016/j.automatica.2016.04.015 · Cited by 159
“…1999; Turksoy, Bayrak, Quinn, Littlejohn, & Cinar, 2013), proportional–integral–derivative control (Marchetti, Barolo, Jovanovič, Zisser, & Seborg, 2008; Steil, Rebrin, Darwin, Hariri, & Saad, 2006), or MD/fuzzy logic (Mauseth et al., 2013; Nimri et al., 2014) have been deployed in human trials.”
Artificial Intelligence Methodologies and Their Application to Diabetes
Rigla, M., García-Sáez, G., Pons, B., & Hernando, M. E. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296817710475 · Cited by 131
Gingras, V., Taleb, N., Roy‐Fleming, A., Legault, L., & Rabasa‐Lhoret, R. (2018) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.13052 · Cited by 113
Metadata
- Authors
- Mauseth, R., Hirsch, I. B., Bollyky, J., Kircher, R., Matheson, D., Sanda, S., & Greenbaum, C.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2013-08
- Volume
- 15
- Issue
- 8
- Pages
- 628-633
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2054915896
- Cited by
- 112
- References
- 3
- FWCI
- 5.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.