Accuracy and Acceptability of the 6-Day Enlite Continuous Subcutaneous Glucose Sensor

Bailey, Timothy S., Ahmann, Andrew, Brazg, Ronald, Christiansen, Mark, Garg, Satish, Watkins, Elaine, Welsh, John B., Lee, Scott W. · 2014 · Diabetes Technology & Therapeutics
Cited by 101

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: This study evaluated the performance and acceptability of the Enlite(®) glucose sensor (Medtronic MiniMed, Inc., Northridge, CA). SUBJECTS AND METHODS: Ninety adults with type 1 or type 2 diabetes wore two Enlite sensors on the abdomen and/or buttock for 6 days and calibrated them at different frequencies. On Days 1, 3, and 6, accuracy was evaluated by comparison of sensor glucose values with frequently sampled plasma glucose values collected over a 12-h period. Accuracy was assessed at different reference glucose concentrations and during times when absolute glucose concentration rates of change were <1, 1-2, and >2 mg/dL/min. The sensor's ability to detect hypoglycemia or hyperglycemia was evaluated with simulated alerts. Subject satisfaction was evaluated with a 7-point Likert-type questionnaire, with a score of 7 indicating strong agreement. RESULTS: With abdomen sensors under actual-use calibration (mean, 2.8 ± 0.9 times/day), the overall mean (median) absolute relative difference (ARD) values between sensor and reference values were 13.6% (10.1%); the corresponding buttock sensor ARD values were 15.5% (10.5%). With abdomen sensors under minimal calibration (mean, 1.2 ± 0.9 times/day), the mean (median) ARD values were 14.7% (10.8%). Mean ARD values of abdomen sensors at rates of change of <1, 1-2, and >2 mg/dL/min were 13.6%, 12.9%, and 16.3%, respectively. With abdomen sensors, 79.5% and 94.1% of hypoglycemic and hyperglycemic events, respectively, were correctly detected; 81.9% and 94.9% of hypoglycemic and hyperglycemic alerts, respectively, were confirmed. The failure rates for abdomen and buttock sensors were 19.7% and 13.9%, respectively. Mean responses to survey questions for all subjects related to comfort and ease of use were favorable. CONCLUSIONS: The Enlite sensor provided accurate data at different glucose concentrations and rates of change. Subjects found the sensor comfortable and easy to use.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2013.0222

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 101

Metadata

Authors
Bailey, T. S., Ahmann, A., Brazg, R., Christiansen, M., Garg, S., Watkins, E., Welsh, J. B., & Lee, S. W.
Venue
Diabetes Technology & Therapeutics
Published
2014-05
Volume
16
Issue
5
Pages
277-283
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W2158434788
Cited by
101
References
1
FWCI
9.34
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy and Acceptability of the 6-Day Enlite Continuous Subcutaneous Glucose Sensor. https://app.cochat.ai/papers/10.1089/dia.2013.0222
The paper
Bailey, T. S., Ahmann, A., Brazg, R., Christiansen, M., Garg, S., Watkins, E., Welsh, J. B., & Lee, S. W. (2014). Accuracy and Acceptability of the 6-Day Enlite Continuous Subcutaneous Glucose Sensor. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2013.0222

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.