CoChat

Intramuscular Risk at Insulin Injection Sites—Measurement of the Distance from Skin to Muscle and Rationale for Shorter-Length Needles for Subcutaneous Insulin Therapy

Hirsch, Laurence, Byron, Karen, Gibney, Michael · 2014 · Diabetes Technology & Therapeutics
Cited by 76

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Intramuscular (IM) injection can increase insulin absorption, causing hypoglycemia. Available needle lengths today are 4-12.7 mm for pens and 6-12.7 mm for syringes. We describe the distance (D) from skin surface to muscle fascia at injection sites for subcutaneous (SC) insulin therapy and recommend needle lengths to reduce IM injection risk. MATERIALS AND METHODS: At two locations in the United States, skin and SC fat thicknesses were measured by ultrasound at the abdomen, arm, thigh, and buttock in diverse adults (body mass index [BMI] range, approximately 19-65 kg/m²) with diabetes (n=341 with one or more paired skin and SC measurement, permitting calculation of D). The natural log of D by body site, BMI, and gender were analyzed using a mixed model to estimate IM risk. RESULTS: D varied significantly by body site, BMI, and gender (each P<0.001), increasing with higher BMI and in women. Median D ranged from 10.9 mm (95% confidence interval, 10.3, 11.6) at the thigh to 16.9 mm (15.9, 18.1) at the buttock. Minimum D was <3 mm at the thigh and <5 mm elsewhere. When inserted 90° without pinch-up, the most commonly used needle worldwide (8 mm) has estimated IM risks of 25% and 9.7%, respectively, in the thigh and abdomen, versus 1.6% and 0.1%, respectively, with a 4 mm needle. A 45° insertion reduces, but does not eliminate, IM risk with longer needles. CONCLUSIONS: Gender, BMI, and body site affect D; when combined with needle length and insertion angle, these factors permit detailed estimates of IM insulin injection risk. Such risk varies across sites, appears greatest at the thigh, is unnecessarily increased with 8 mm and 12.7 mm needles, and is greatly reduced with shorter-length needles and good injection technique.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2014.0111

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 76

Metadata

Authors
Hirsch, L., Byron, K., & Gibney, M.
Venue
Diabetes Technology & Therapeutics
Published
2014-12
Volume
16
Issue
12
Pages
867-873
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W1505566231
Cited by
76
References
2
FWCI
3.59
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Intramuscular Risk at Insulin Injection Sites—Measurement of the Distance from Skin to Muscle and Rationale for Shorter-Length Needles for Subcutaneous Insulin Therapy. https://app.cochat.ai/papers/10.1089/dia.2014.0111
The paper
Hirsch, L., Byron, K., & Gibney, M. (2014). Intramuscular Risk at Insulin Injection Sites—Measurement of the Distance from Skin to Muscle and Rationale for Shorter-Length Needles for Subcutaneous Insulin Therapy. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2014.0111

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.