Multinight “Bedside” Closed-Loop Control for Patients with Type 1 Diabetes
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Studies of closed-loop control (CLC) systems have improved glucose levels in patients with type 1 diabetes. In this study we test a new CLC concept aiming to "reset" the patient overnight to near-normoglycemia each morning, for several consecutive nights. SUBJECTS AND METHODS: Ten insulin pump users with type 1 diabetes (mean age, 46.4±8.5 years) were enrolled in a two-center (in the United States and Italy) randomized crossover trial comparing 5 consecutive nights of CLC (23:00-07:00 h) in an outpatient setting versus sensor-augmented insulin pump therapy of the same duration at home. Primary end points included time spent in 80-140 mg/dL as measured by continuous glucose monitoring overnight and fasting blood glucose distribution at 7:00 h. RESULTS: Compared with sensor-augmented pump therapy, CLC improved significantly time spent between 80 and 140 mg/dL (54.5% vs. 32.2%; P<0.001) and between 70 and 180 mg/dL (85.4% vs. 59.1%; P<0.001); CLC reduced the mean glucose level at 07:00 h (119.3 vs. 152.9 mg/dL; P<0.001) and overnight mean glucose level (139.0 vs. 170.3 mg/dL; P<0.001) using a marginally lower amount of insulin (6.1 vs. 6.8 units; P=0.1). Tighter overnight control led to improved daytime control on the next day: the overnight/next-day control correlation was r=0.52, P<0.01. CONCLUSIONS: Multinight CLC of insulin delivery (artificial pancreas) results in significant improvement in morning and overnight glucose levels and time in target range, with the potential to improve daytime control when glucose levels were "reset" to near-normoglycemia each morning.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Artificial Pancreas: Past, Present, Future
Cobelli, C., Renard, E., & Kovatchev, B. (2011) · Diabetes · doi:10.2337/db11-0654 · Cited by 600
Self-citationA Bihormonal Closed-Loop Artificial Pancreas for Type 1 Diabetes
El-Khatib, F. H., Russell, S. J., Nathan, D. M., Sutherlin, R. G., & Damiano, E. R. (2010) · Science Translational Medicine · doi:10.1126/scitranslmed.3000619 · Cited by 403 · cited 1×
“Patients were asked (1) to check a capillary glucose measurement by fingerstick at least four times a day, including at wake-up and bedtime, (2) to use the bolus calculator function in the pump to record carbohydrates consumed and all insulin boluses delivered, (3) make all insulin dosing decisions per their usual car…”
MethodFully Integrated Artificial Pancreas in Type 1 Diabetes
Breton, M., Farret, A., Bruttomesso, D., Anderson, S., Magni, L., Patek, S., Dalla Man, C., Place, J., Demartini, S., Del Favero, S., et al. (2012) · Diabetes · doi:10.2337/db11-1445 · Cited by 315
Self-citationKovatchev, B., Cobelli, C., Renard, E., Anderson, S., Breton, M., Patek, S., Clarke, W., Bruttomesso, D., Maran, A., Costa, S., et al. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400611 · Cited by 200
Self-citation
Cited by
Continuous Glucose Monitoring: A Review of Successes, Challenges, and Opportunities
Rodbard, D. (2016) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2015.0417 · Cited by 737
Weisman, A., Bai, J.-W., Cardinez, M., Kramer, C. K., & Perkins, B. A. (2017) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(17)30167-5 · Cited by 463
Metrics for glycaemic control - from HbA1c to continuous glucose monitoring
Kovatchev, B. P. (2017) · Nature Reviews Endocrinology · doi:10.1038/nrendo.2017.3 · Cited by 272
Self-citationComing of age: the artificial pancreas for type 1 diabetes
Thabit, H., & Hovorka, R. (2016) · Diabetologia · doi:10.1007/s00125-016-4022-4 · Cited by 223
ISPAD Clinical Practice Consensus Guidelines 2018: diabetes technologies
Sherr, J. L., Tauschmann, M., Battelino, T., de Bock, M., Forlenza, G., Roman, R., Hood, K. K., & Maahs, D. M. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12731 · Cited by 197
Metadata
- Authors
- Brown, S. A., Kovatchev, B. P., Breton, M. D., Anderson, S. M., Keith-Hynes, P., Patek, S. D., Jiang, B., Ben Brahim, N., Vereshchetin, P., Bruttomesso, D., Avogaro, A., Del Favero, S., Boscari, F., Galasso, S., Visentin, R., Monaro, M., & Cobelli, C.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2015-03
- Volume
- 17
- Issue
- 3
- Pages
- 203-209
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W115895616
- Cited by
- 64
- References
- 4
- FWCI
- 8.61
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.