Development of a New Measure for Assessing Glucose Monitoring Device-Related Treatment Satisfaction and Quality of Life
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Many different devices are available to patients to measure glucose levels, but there is no validated method to assess treatment satisfaction with glucose monitoring devices and its impact on quality of life and other patient-reported outcomes. To address this problem, we developed the Glucose Monitoring System Satisfaction Survey (GMSS). We describe the construction and validation of the GMSS and examine how key patient factors are associated with glucose device satisfaction. MATERIALS AND METHODS: Items were developed from interviews with 15 adults with either type 1 diabetes (T1D) or type 2 diabetes (T2D) and 10 diabetes healthcare professionals, resulting in an initial pool of 42 items. Separate exploratory factor analyses (EFAs) were conducted with adults with T1D (n=254) and with insulin-using T2D (n=206). Construct validity was established with overall well-being (World Health Organization-5), diabetes distress (Diabetes Distress Scale), attitudes toward glucose monitoring (Self-Monitoring of Blood Glucose Obstacles scale), and the previously validated Blood Glucose Monitoring System Rating Questionnaire. Regression analyses examined associations between total scale satisfaction and demographics, diabetes status, and glucose monitor use. RESULTS: The two EFAs resulted in two 15-item scales, one for T1D and one for T2D, and yielded four coherent and meaningful factors in each sample: three factors with the same items in common for both samples (Emotional Burden, Behavioral Burden, and Openness) and a fourth factor unique to each sample (Trust for T1D, Worthwhileness for T2D). The final EFA accounted for 66.5% of the variance in the T1D sample and 67.0% in the T2D sample. Validity was established by significant correlations with criterion variables. CONCLUSIONS: The GMSS is a reliable, valid measure of glucose device satisfaction in its T1D form and in its insulin-using T2D form. It provides a comprehensive profile of sources of device satisfaction for use in clinical care and research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring Numeracy without a Math Test: Development of the Subjective Numeracy Scale
Fagerlin, A., Zikmund-Fisher, B. J., Ubel, P. A., Jankovic, A., Derry, H. A., & Smith, D. M. (2007) · Medical Decision Making · doi:10.1177/0272989x07304449 · Cited by 960
Understanding the sources of diabetes distress in adults with type 1 diabetes
Fisher, L., Polonsky, W. H., Hessler, D. M., Masharani, U., Blumer, I., Peters, A. L., Strycker, L. A., & Bowyer, V. (2015) · Journal of Diabetes and its Complications · doi:10.1016/j.jdiacomp.2015.01.012 · Cited by 414
Self-citation
Cited by
Heinemann, L., Freckmann, G., Ehrmann, D., Faber-Heinemann, G., Guerra, S., Waldenmaier, D., & Hermanns, N. (2018) · The Lancet · doi:10.1016/s0140-6736(18)30297-6 · Cited by 522
Laffel, L. M., Kanapka, L. G., Beck, R. W., Bergamo, K., Clements, M. A., Criego, A., DeSalvo, D. J., Goland, R., Hood, K., Liljenquist, D., et al. (2020) · JAMA · doi:10.1001/jama.2020.6940 · Cited by 443
Bergenstal, R. M., Nimri, R., Beck, R. W., Criego, A., Laffel, L., Schatz, D., Battelino, T., Danne, T., Weinzimer, S. A., Sibayan, J., et al. (2021) · The Lancet · doi:10.1016/s0140-6736(20)32514-9 · Cited by 344
Intermittently scanned continuous glucose monitoring for type 1 diabetes
Leelarathna, L., Evans, M. L., Neupane, S., Rayman, G., Lumley, S., Cranston, I., Narendran, P., Barnard-Kelly, K., Sutton, C. J., Elliott, R. A., et al. (2022) · New England Journal of Medicine · doi:10.1056/nejmoa2205650 · Cited by 174
Aronson, R., Brown, R. E., Chu, L., Bajaj, H. S., Khandwala, H., Abitbol, A., Malakieh, N., & Goldenberg, R. (2023) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.14949 · Cited by 118
Metadata
- Authors
- Polonsky, W. H., Fisher, L., Hessler, D., & Edelman, S. V.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2015-09
- Volume
- 17
- Issue
- 9
- Pages
- 657-663
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2121241046
- Cited by
- 98
- References
- 2
- FWCI
- 1.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development of a New Measure for Assessing Glucose Monitoring Device-Related Treatment Satisfaction and Quality of Life. https://app.cochat.ai/papers/10.1089/dia.2014.0417
- The paper
- Polonsky, W. H., Fisher, L., Hessler, D., & Edelman, S. V. (2015). Development of a New Measure for Assessing Glucose Monitoring Device-Related Treatment Satisfaction and Quality of Life. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2014.0417
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.