Accuracy Evaluation of Four Blood Glucose Monitoring Systems in Unaltered Blood Samples in the Low Glycemic Range and Blood Samples in the Concentration Range Defined by ISO 15197

Freckmann, Guido, Pleus, Stefan, Link, Manuela, Baumstark, Annette, Schmid, Christina, Högel, Josef, Haug, Cornelia · 2015 · Diabetes Technology & Therapeutics
Cited by 37

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Introduction: Systems for self-monitoring of blood glucose (SMBG) are expected to be accurate enough to provide reliable measurement results. Especially in the low glycemic range, adequate therapeutic decisions based on reliable results can alleviate complications associated with hypoglycemia. Materials and Methods: The accuracy of four SMBG systems (system 1 was the ACCU-CHEK ® Aviva [Roche Diagnostics GmbH, Mannheim, Germany], system 2 was the Contour ® XT [Bayer Consumer Care AG, Basel, Switzerland], system 3 was the GlucoCheck XL [aktivmed GmbH, Augsberg, Germany], and system 4 was the GlucoMen ® LX PLUS [A. Menarini Diagnostics S.r.l., Florence, Italy]) with three test-strip lots each was evaluated by calculating mean absolute relative differences (MARDs). Two datasets were evaluated: (1) 100 samples with blood glucose concentrations <70 mg/dL and (2) 100 samples distributed following International Organization for Standardization (ISO) standard 15197. Each sample was measured twice with each test-strip lot of each SMBG system. Comparison measurement results were obtained with a glucose oxidase method and a hexokinase method, both traceable according to ISO 17511. Analysis of variance of the MARD between the SMBG system and the comparison method was performed. Results: MARD values ranged from 4.4% to 13.4% (<70 mg/dL) and 4.8% to 8.9% (ISO 15197-distributed) and differed significantly, with systems 1 and 2 showing lower MARDs than systems 3 and 4. MARD values deviated by up to 2.5% (corresponding to a relative deviation of approximately 40%) between the two comparison methods. Conclusions: The investigated SMBG systems showed a significant variation of accuracy (measured by MARD), especially with higher MARD values in the low glycemic range. The selected comparison method had an impact on the MARD and therefore on the apparent accuracy of the SMBG systems. Sufficient measurement accuracy in the low glycemic range is required to enable users to react adequately to hypoglycemia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2015.0043

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

Metadata

Authors
Freckmann, G., Pleus, S., Link, M., Baumstark, A., Schmid, C., Högel, J., & Haug, C.
Venue
Diabetes Technology & Therapeutics
Published
2015-09
Volume
17
Issue
9
Pages
625-634
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W2159241065
Cited by
37
References
6
FWCI
6.33
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.