Accuracy Evaluation of Four Blood Glucose Monitoring Systems in Unaltered Blood Samples in the Low Glycemic Range and Blood Samples in the Concentration Range Defined by ISO 15197
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Introduction: Systems for self-monitoring of blood glucose (SMBG) are expected to be accurate enough to provide reliable measurement results. Especially in the low glycemic range, adequate therapeutic decisions based on reliable results can alleviate complications associated with hypoglycemia. Materials and Methods: The accuracy of four SMBG systems (system 1 was the ACCU-CHEK ® Aviva [Roche Diagnostics GmbH, Mannheim, Germany], system 2 was the Contour ® XT [Bayer Consumer Care AG, Basel, Switzerland], system 3 was the GlucoCheck XL [aktivmed GmbH, Augsberg, Germany], and system 4 was the GlucoMen ® LX PLUS [A. Menarini Diagnostics S.r.l., Florence, Italy]) with three test-strip lots each was evaluated by calculating mean absolute relative differences (MARDs). Two datasets were evaluated: (1) 100 samples with blood glucose concentrations <70 mg/dL and (2) 100 samples distributed following International Organization for Standardization (ISO) standard 15197. Each sample was measured twice with each test-strip lot of each SMBG system. Comparison measurement results were obtained with a glucose oxidase method and a hexokinase method, both traceable according to ISO 17511. Analysis of variance of the MARD between the SMBG system and the comparison method was performed. Results: MARD values ranged from 4.4% to 13.4% (<70 mg/dL) and 4.8% to 8.9% (ISO 15197-distributed) and differed significantly, with systems 1 and 2 showing lower MARDs than systems 3 and 4. MARD values deviated by up to 2.5% (corresponding to a relative deviation of approximately 40%) between the two comparison methods. Conclusions: The investigated SMBG systems showed a significant variation of accuracy (measured by MARD), especially with higher MARD values in the low glycemic range. The selected comparison method had an impact on the MARD and therefore on the apparent accuracy of the SMBG systems. Sufficient measurement accuracy in the low glycemic range is required to enable users to react adequately to hypoglycemia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Factors affecting blood glucose monitoring: sources of errors in measurement
Ginsberg, B. H. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300438 · Cited by 348
Effects of Acute Insulin-Induced Hypoglycemia on Indices of Inflammation
Wright, R. J., Newby, D. E., Stirling, D., Ludlam, C. A., Macdonald, I. A., & Frier, B. M. (2010) · Diabetes Care · doi:10.2337/dc10-0013 · Cited by 208
Effects of controlled hypoglycaemia on cardiac repolarisation in patients with type 1 diabetes
Koivikko, M. L., Karsikas, M., Salmela, P. I., Tapanainen, J. S., Ruokonen, A., Seppänen, T., Huikuri, H. V., & Perkiömäki, J. S. (2008) · Diabetologia · doi:10.1007/s00125-007-0902-y · Cited by 89
Self-Monitoring of Blood Glucose: The Use of the First or the Second Drop of Blood
Hortensius, J., Slingerland, R. J., Kleefstra, N., Logtenberg, S. J. J., Groenier, K. H., Houweling, S. T., & Bilo, H. J. G. (2011) · Diabetes Care · doi:10.2337/dc10-1694 · Cited by 76
Klaff, L. J., Brazg, R., Hughes, K., Tideman, A. M., Schachner, H. C., Stenger, P., Pardo, S., Dunne, N., & Parkes, J. L. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0069 · Cited by 46
(2015) · doi:10.1177/1932296815580161 · Cited by 31
Self-citation
Cited by
Measures of Accuracy for Continuous Glucose Monitoring and Blood Glucose Monitoring Devices
Freckmann, G., Pleus, S., Grady, M., Setford, S., & Levy, B. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818812062 · Cited by 202
Self-citationComparative accuracy of 17 point-of-care glucose meters
Ekhlaspour, L., Mondesir, D., Lautsch, N., Balliro, C., Hillard, M., Magyar, K., Radocchia, L. G., Esmaeili, A., Sinha, M., & Russell, S. J. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816672237 · Cited by 127
(2015) · doi:10.1177/1932296815580161 · Cited by 31
Self-citation
Metadata
- Authors
- Freckmann, G., Pleus, S., Link, M., Baumstark, A., Schmid, C., Högel, J., & Haug, C.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2015-09
- Volume
- 17
- Issue
- 9
- Pages
- 625-634
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2159241065
- Cited by
- 37
- References
- 6
- FWCI
- 6.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.