CoChat

Randomized Evaluation of Glycemic Control in the Medical Intensive Care Unit Using Real-Time Continuous Glucose Monitoring (REGIMEN Trial)

De Block, Christophe E.M., Gios, Jens, Verheyen, Nina, Manuel-y-Keenoy, Begoña, Rogiers, Peter, Jorens, Philippe G., Scuffi, Cosimo, Van Gaal, Luc F. · 2015 · Diabetes Technology & Therapeutics
Cited by 50

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

BACKGROUND AND OBJECTIVE: Hyperglycemia occurs commonly in patients admitted to medical intensive care units (MICUs). Whether real-time (RT) continuous glucose monitoring (CGM) improves glycemic control and variability and reduces hypoglycemia in severely ill MICU patients with an Acute Physiology and Chronic Health Evaluation II (APACHE-II) score of ≥20 has not been studied. SUBJECTS AND METHODS: Thirty-five patients (66 ± 10 years of age; APACHE-II score, 28 ± 6) were randomly assigned to RT-CGM (n = 16) using the GlucoDay(®)S (A. Menarini Diagnostics, Florence, Italy) device or to blinded CGM. Insulin was infused using a modified Yale protocol targeting a blood glucose level between 80 and 120 mg/dL. Outcome measures were percentage of time in normoglycemia (80-110 mg/dL) and in hypoglycemia (<60 mg/dL), glycemic variability (SD, coefficient of variation, mean amplitude of glucose excursions, and mean of daily differences), and CGM accuracy (error grid analyses, Bland-Altman bias plot, and mean absolute relative deviation). RESULTS: During 96 h of monitoring, glycemia reached target (80-110 mg/dL) in 37 ± 15%, was between 70 and 180 mg/dL in 91 ± 10%, and <60 mg/dL in 2 ± 2% of the time. In the RT-CGM group glycemia averaged 119 ± 17 mg/dL versus 122 ± 11 mg/dL in the control group. Parameters of glucose variability and percentages of time at target glycemia and in hypoglycemia were similar between groups. GlucoDayS values and arterial glycemia correlated well, with 98.6% of data falling in Zones A and B of the error grid analysis. Mean absolute relative devation was 11.2%. CONCLUSIONS: RT-CGM did not ameliorate glucose control or variability; neither did it reduce the number of hypoglycemic events, but our insulin infusion protocol led to overall good glucose control without a significant hypoglycemia risk, making further improvement difficult.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2015.0151

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

Metadata

Authors
De Block, C. E. M., Gios, J., Verheyen, N., Manuel-y-Keenoy, B., Rogiers, P., Jorens, P. G., Scuffi, C., & Van Gaal, L. F.
Venue
Diabetes Technology & Therapeutics
Published
2015-12
Volume
17
Issue
12
Pages
889-898
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W1661463411
Cited by
50
References
8
FWCI
3.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.