CoChat

Measures of Glycemic Variability in Type 1 Diabetes and the Effect of Real-Time Continuous Glucose Monitoring

El-Laboudi, Ahmed H., Godsland, Ian F., Johnston, Desmond G., Oliver, Nick S. · 2016 · Diabetes Technology & Therapeutics
Cited by 84

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Objective: To report the impact of continuous glucose monitoring (CGM) on glycemic variability (GV) indices, factors predictive of change, and to correlate variability with conventional markers of glycemia. Methods: Data from the JDRF study of CGM in participants with type 1 diabetes were used. Participants were randomized to CGM or self-monitored blood glucose (SMBG). GV indices at baseline, at 26 weeks in both groups, and at 52 weeks in the control group were analyzed. The associations of demographic and clinical factors with change in GV indices from baseline to 26 weeks were evaluated. Results: Baseline data were available for 448 subjects. GV indices were all outside normative ranges ( P < 0.001). Intercorrelation between GV indices was common and, apart from coefficient of variation (CV), low blood glucose index (LBGI), and percentage of glycemic risk assessment diabetes equation score attributable to hypoglycemia (%GRADE hypoglycemia ), all indices correlate positively with HbA1c. There was strong correlation between time spent in hypoglycemia, and CV, LBGI, and %GRADE hypoglycemia , but not with HbA1c. A significant reduction in all GV indices, except lability index and mean absolute glucose change per unit time (MAG), was demonstrated in the intervention group at 26 weeks compared with the control group. Baseline factors predicting a change in GV with CGM include baseline HbA1c, baseline GV, frequency of daily SMBG, and insulin pump use. Conclusions: CGM reduces most GV indices compared with SMBG in people with type 1 diabetes. The strong correlation between time spent in hypoglycemia and CV, LBGI, and %GRADE hypoglycemia highlights the value of these metrics in assessing hypoglycemia as an adjunct to HbA1c in the overall assessment of glycemia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2016.0146

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 84

Metadata

Authors
El-Laboudi, A. H., Godsland, I. F., Johnston, D. G., & Oliver, N. S.
Venue
Diabetes Technology & Therapeutics
Published
2016-12
Volume
18
Issue
12
Pages
806-812
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W2573264143
Cited by
84
References
6
FWCI
8.08
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.